SearcharxivSearch

arXiv subjects

Daniel Lange

Publications and source records attributed to Daniel Lange.

6 recordsLinked to original sources

Probing new bosons and nuclear structure with ytterbium isotope shifts

In this Letter, we present mass-ratio measurements on highly charged Yb$^{42+}$ ions with a precision of $4\times 10^{-12}$ and isotope-shift measurements on Yb$^{+}$ on the $^{2}$S$_{1/2}$ $\to$ $^{2}$D$_{5/2}$ and $^{2}$S$_{1/2}$ $\to$ $^{2}$F$_{7/2}$ transitions with a precision of $4\times 10^{-9}$ for the isotopes $^{168,170,172,174,176}$Yb. We present a new method that allows us to extract higher-order changes in the nuclear charge distribution along the Yb isotope chain, benchmarking ab-initio nuclear structure calculations. Additionally, we perform a King plot analysis to set bounds on a fifth force in the keV$/c^2$ to MeV$/c^2$ range coupling to electrons and neutrons.

physics.atom-ph

Penning-trap measurement of the $Q$-value of the electron capture in $^{163}\mathrm{Ho}$ for the determination of the electron neutrino mass

The investigation of the absolute scale of the effective neutrino mass remains challenging due to the exclusively weak interaction of neutrinos with all known particles in the standard model of particle physics. Currently, the most precise and least model-dependent upper limit on the electron antineutrino mass is set by the KATRIN experiment from the analysis of the tritium \b{eta}-decay. Another promising approach is the electron capture in $^{163}\mathrm{Ho}$, which is under investigation using microcalorimetry within the ECHo and HOLMES collab orations. An independently measured Q-value of this process is vital for the assessment of systematic uncertainties in the neutrino mass determination. Here, we report a direct, independent determination of this $Q$-value by measuring the free-space cyclotron frequency ratio of highly charged ions of $^{163}\mathrm{Ho}$ and $^{163}\mathrm{Dy}$ in the Penning trap experiment \textsc{Pentatrap}. Combining this ratio with atomic physics calculations of the electronic binding energies yields a $Q$-value of $2863.2(0.6)\,\mathrm{eV}/c^{2}$ - a more than 50-fold improvement over the state-of-the-art. This will enable the determination of the electron neutrino mass on a sub-eV level from the analysis of the electron capture in $^{163}\mathrm{Ho}$.

nucl-ex

Fast Silicon Carbide MOSFET based high-voltage push-pull switch for charge state separation of highly charged ions with a Bradbury-Nielsen Gate

In this paper we report on the development of a fast high-voltage switch, which is based on two enhancement mode N-channel Silicon Carbide Metal Oxide Semiconductor Field-Effect Transistors in push-pull configuration. The switch is capable of switching high voltages up to 600 V on capacitive loads with rise and fall times on the order of 10 ns and pulse widths $\leq$ 20 ns. Using this switch it was demonstrated that from the charge state distribution of bunches of highly charged ions ejected from an electron beam ion trap with a specific kinetic energy, single charge states can be separated by fast switching of the high voltage applied to a Bradbury-Nielsen Gate with a resolving power of about 100.

physics.ins-det

Observation of a low-lying metastable electronic state in highly charged lead by Penning-trap mass spectrometry

Highly charged ions (HCIs) offer many opportunities for next-generation clock research due to the vast landscape of available electronic transitions in different charge states. The development of XUV frequency combs has enabled the search for clock transitions based on shorter wavelengths in HCIs. However, without initial knowledge of the energy of the clock states, these narrow transitions are difficult to be probed by lasers. In this Letter, we provide experimental observation and theoretical calculation of a long-lived electronic state in Nb-like Pb$^{41+}$ which could be used as a clock state. With the mass spectrometer Pentatrap, the excitation energy of this metastable state is directly determined as a mass difference at an energy of 31.2(8) eV, corresponding to one of the most precise relative mass determinations to date with a fractional uncertainty of $4\times10^{-12}$. This experimental result agrees within 1 $\sigma$ with two partially different \textit{ab initio} multi-configuration Dirac-Hartree-Fock calculations of 31.68(13) eV and 31.76(35) eV, respectively. With a calculated lifetime of 26.5(5.3) days, the transition from this metastable state to the ground state bears a quality factor of $1.1\times10^{23}$ and allows for the construction of a HCI clock with a fractional frequency instability of $<10^{-19}/\sqrt{\tau}$.

physics.atom-ph

High-precision mass measurement of doubly magic $^{208}$Pb

The absolute atomic mass of $^{208}$Pb has been determined with a fractional uncertainty of $7\times 10^{-11}$ by measuring the cyclotron-frequency ratio $R$ of $^{208}$Pb$^{41+}$ to $^{132}$Xe$^{26+}$ with the high-precision Penning-trap mass spectrometer Pentatrap and computing the binding energies $E_{\text{Pb}}$ and $E_{\text{Xe}}$ of the missing 41 and 26 atomic electrons, respectively, with the ab initio fully relativistic multi-configuration Dirac-Hartree-Fock (MCDHF) method. $R$ has been measured with a relative precision of $9\times 10^{-12}$. $E_{\text{Pb}}$ and $E_{\text{Xe}}$ have been computed with an uncertainty of 9.1 eV and 2.1 eV, respectively, yielding $207.976\,650\,571(14)$ u (u$=9.314\,941\,024\,2(28)\times 10^{8}$ eV/c$^2$) for the $^{208}$Pb neutral atomic mass. This result agrees within $1.2\sigma$ with that from the Atomic-Mass Evaluation (AME) 2020, while improving the precision by almost two orders of magnitude. The new mass value directly improves the mass precision of 14 nuclides in the region of Z=81-84 and is the most precise mass value with A>200. Thus, the measurement establishes a new region of reference mass values which can be used e.g. for precision mass determination of transuranium nuclides, including the superheavies.

nucl-ex

A Digital Feedback System for Advanced Ion Manipulation Techniques in Penning Traps

The possibility to apply active feedback to a single ion in a Penning trap using a fully digital system is demonstrated. Previously realized feedback systems rely on analog circuits that are susceptible to environmental fluctuations and long term drifts, as well as being limited to the specific task they were designed for. The presented system is implemented using an FPGA-based platform (STEMlab), offering greater flexibility, higher temporal stability and the possibility for highly dynamic variation of feedback parameters. The system's capabilities were demonstrated by applying feedback to the ion detection system primarily consisting of a resonant circuit. This allowed shifts in its resonance frequency of up to several kHz and free modification of its quality factor within two orders of magnitude, which reduces the temperature of a single ion by a factor of 6. Furthermore, a phase-sensitive detection technique for the axial ion oscillation was implemented, which reduces the current measurement time by two orders of magnitude while simultaneously eliminating model-related systematic uncertainties. The use of FPGA technology allowed the implementation of a fully-featured data acquisition system, making it possible to realize feedback techniques that require constant monitoring of the ion signal. This was successfully used to implement a single-ion self-excited oscillator.

physics.atom-ph