Searcharxiv⌕ Search

arXiv subjects

Daniel N. McKinsey

Publications and source records attributed to Daniel N. McKinsey.

9 recordsLinked to original sources

Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter

We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal phonon events, and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These ``singles'' are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

physics.ins-det↗

A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning

The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.

physics.ins-det↗

Thermodynamic Stability of Xenon-Doped Liquid Argon Detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we discuss the causes for such instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

physics.ins-det↗

Visualization of the normal-fluid turbulence in counterflowing superfluid 4He

We describe a new technique, using thin lines of triplet-state He2 molecular tracers created by femtosecond-laser field-ionization of helium atoms, for visualizing the flow of the normal fluid in superfluid 4He, together with its application to thermal counterflow in a channel. We show that, at relatively small velocities, where the superfluid is already turbulent, the flow of the normal fluid remains laminar, but with a distorted velocity profile, while at a higher velocity there is a transition to turbulence. The form of the structure function in this turbulent state differs significantly from that found in types of conventional turbulence. This visualization technique also promises to be applicable to other fluid dynamical problems involving cryogenic helium.

cond-mat.other↗

Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping

Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from 9 +/- 5 ppm to 1100 +/- 500 ppm xenon (by weight) in 6 steps. The 3.14-liter detector uses tetraphenyl butadiene (TPB) wavelength shifter with dual photomultiplier tubes and is operated in single-phase mode. Gamma-ray-interaction signal yield of 4.0 +/- 0.1 photoelectrons/keV improved to 5.0 +/- 0.1 photoelectrons/keV with dopant. Energy resolution at 662 keV improved from (4.4 +/- 0.2)% (σ) to (3.5 +/- 0.2)% (σ) with dopant. Pulse-shape discrimination performance degraded greatly at the first addition of dopant, slightly improved with additional additions, then rapidly improved near the end of our dopant range, with performance becoming slightly better than pure argon at the highest tested dopant concentration. Some evidence of reduced neutron scintillation efficiency with increasing dopant concentration was observed. Finally, the waveform shape outside the TPB region is discussed, suggesting that the contribution to the waveform from xenon-produced light is primarily in the last portion of the slow component.

physics.ins-det↗

A Concept for A Dark Matter Detector Using Liquid Helium-4

Direct searches for light dark matter particles (mass $<10$ GeV) are especially challenging because of the low energies transferred in elastic scattering to typical heavy nuclear targets. We investigate the possibility of using liquid Helium-4 as a target material, taking advantage of the favorable kinematic matching of the Helium nucleus to light dark matter particles. Monte Carlo simulations are performed to calculate the charge, scintillation, and triplet helium molecule signals produced by recoil He ions, for a variety of energies and electric fields. We show that excellent background rejection can be achieved based on the ratios between different signal channels. We also present some concepts for a liquid-helium-based dark matter detector. Key to the proposed approach is the use of a large electric field to extract electrons from the event site, and the amplification of this charge signal, through proportional scintillation, liquid electroluminescence, or roton emission. The sensitivity of the proposed detector to light dark matter particles is estimated for various electric fields and light collection efficiencies.

astro-ph.IM↗

Visualization study of counterflow in superfluid helium-4 using metastable helium molecules

Heat is carried in superfluid He-4 by the motion of the normal fluid$^{1}$, a counterflowing superfluid component serving to eliminate any net mass flow. It has been known for many years that above a critical heat current the superfluid component in this counterflow becomes turbulent. This turbulence takes the form of a disorganized tangle of quantized vortex lines and is maintained by the relative motion of the two fluids$^{2-3}$. It has been suspected that the normal fluid may also become turbulent$^{4}$, but experimental verification is difficult without a technique for visualizing the flow. Here we report a series of visualization studies on the normal-fluid component in a thermal counterflow performed by imaging the motion of seeded metastable helium molecules using a laser-induced-fluorescence technique$^{5-8}$. We present evidence that the flow of the normal fluid is indeed turbulent, at least at relatively large velocities. Thermal counterflow in which both components are turbulent presents us with a new and theoretically challenging type of turbulent behaviour.

physics.flu-dyn↗

Demonstration of photomultiplier tube operation at 29 K

We describe measurements of gain, dark current, and quantum efficiency obtained while cooling a Hamamatsu R5912-02-MOD photomultiplier tube from room temperature to 29 K. We found that the PMT operated normally down to 29 K, with a reduced gain and quantum efficiency at the lowest temperatures. Furthermore, we found that the dark count rate increased as the temperature decreased. We conclude that these PMTs appear to be adequate for the requirements of the CLEAN experiment.

astro-ph↗

Spatial methods for event reconstruction in CLEAN

In CLEAN (Cryogenic Low Energy Astrophysics with Noble gases), a proposed neutrino and dark matter detector, background discrimination is possible if one can determine the location of an ionizing radiation event with high accuracy. We simulate ionizing radiation events that produce multiple scintillation photons within a spherical detection volume filled with liquid neon. We estimate the radial location of a particular ionizing radiation event based on the observed count data corresponding to that event. The count data are collected by detectors mounted at the spherical boundary of the detection volume. We neglect absorption, but account for Rayleigh scattering. To account for wavelength-shifting of the scintillation light, we assume that photons are absorbed and re-emitted at the detectors. Here, we develop spatial Maximum Likelihood methods for event reconstruction, and study their performance in computer simulation experiments. We also study a method based on the centroid of the observed count data. We calibrate our estimates based on training data.

physics.data-an↗