Searcharxiv⌕ Search

arXiv subjects

Daniel R McGowan

Publications and source records attributed to Daniel R McGowan.

3 recordsLinked to original sources

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.

cs.LG↗

Autopet Challenge 2023: nnUNet-based whole-body 3D PET-CT Tumour Segmentation

Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) combined with Computed Tomography (CT) scans are critical in oncology to the identification of solid tumours and the monitoring of their progression. However, precise and consistent lesion segmentation remains challenging, as manual segmentation is time-consuming and subject to intra- and inter-observer variability. Despite their promise, automated segmentation methods often struggle with false positive segmentation of regions of healthy metabolic activity, particularly when presented with such a complex range of tumours across the whole body. In this paper, we explore the application of the nnUNet to tumour segmentation of whole-body PET-CT scans and conduct different experiments on optimal training and post-processing strategies. Our best model obtains a Dice score of 69\% and a false negative and false positive volume of 6.27 and 5.78 mL respectively, on our internal test set. This model is submitted as part of the autoPET 2023 challenge. Our code is available at: https://github.com/anissa218/autopet\_nnunet

eess.IV↗

On Biases in a UK Biobank-based Retinal Image Classification Model

Recent work has uncovered alarming disparities in the performance of machine learning models in healthcare. In this study, we explore whether such disparities are present in the UK Biobank fundus retinal images by training and evaluating a disease classification model on these images. We assess possible disparities across various population groups and find substantial differences despite strong overall performance of the model. In particular, we discover unfair performance for certain assessment centres, which is surprising given the rigorous data standardisation protocol. We compare how these differences emerge and apply a range of existing bias mitigation methods to each one. A key insight is that each disparity has unique properties and responds differently to the mitigation methods. We also find that these methods are largely unable to enhance fairness, highlighting the need for better bias mitigation methods tailored to the specific type of bias.

cs.LG↗