SearcharxivSearch

arXiv subjects

Daniel Unger

Publications and source records attributed to Daniel Unger.

3 recordsLinked to original sources

Nuclear Charge Radius of $^9$Be from Muonic Atom Spectroscopy Using a Microcalorimeter

The $2p\to1s$ transition energy in muonic $^9$Be was measured using a metallic magnetic calorimeter, resulting in $E_{2p\to 1s}=33\,391.48(34)\,$eV. The result is 30 times more precise than the previous best measurement and enables the extraction of the corresponding nuclear charge radius $r_c($$^9$Be$)=2.5506(51)\,$fm. It is $2.4$ times more precise than the commonly used value based on electron scattering and differs from it by $2.3$ times the combined uncertainties. This measurement represents the first determination of a nuclear charge radius using muonic x-ray spectroscopy with microcalorimeters.

nucl-ex

MMC Array to Study X-ray Transitions in Muonic Atoms

The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We discuss the performance achieved with the maXs-30 detector module to be used. To place the detector close to the target chamber where the muon beam will impact the material under study, we have developed a new dilution refrigerator sidearm. We further discuss the expected efficiency given the transparency of the X-ray windows and the quantum efficiency of the detector. The expected muonic X-ray rate combined with the high resolving power and detection efficiency of the detector suggest that QUARTET will be able to study the de-excitation of light muonic atoms at an unprecedented level, increasing the relative energy resolution by up to a factor of 20 compared to conventional detector techniques.

physics.ins-det

Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei

We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.

physics.atom-ph