SearcharxivSearch

arXiv subjects

Daniel Wenz

Publications and source records attributed to Daniel Wenz.

4 recordsLinked to original sources

GRANITE: Mechanical Characterization and Optical Inspection of Large-Area TPC Electrodes

Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for mechanical stability and high-voltage performance of such an experiment, we have developed a scanning setup for electrode quality assurance called GRANITE: Granular Robotic Assay for Novel Integrated TPC Electrodes. GRANITE is built around a gantry robot on top of a $2.5\,\text{m}\times1.8\,\text{m}$ granite table, equipped with a suite of non-contact metrology devices. We demonstrate the setup's capabilities in two key areas: first, using laser scanners, we characterize wire tension, and in an independent measurement wire deflection due to gravity and electrostatic forces is determined. The setup achieves a precision of $20\,\mu\text{m}$ for the relative measurement of only electrostatic displacement. Furthermore, GRANITE can measure gravitational sag down to $200\,\mu\text{m}$ in an absolute measurement; this precision improves to $50\,\mu\text{m}$ when applying model-based corrections for systematic effects. The performance achieved exceeds the needs for the characterisation of the electrode sagging in future experiments, which typically aims to ensure a maximal sag on the order of $500\,\mu\text{m}$. Second, we use GRANITE's high resolution camera to image all wires of XENON1T's cathode grid. Subsets of these images are then hand sorted and used to train an autoencoder, to reliably classify wire images as either pristine wires or images containing severe anomalous features. These anomalies appear e.g. as staining and may be potential defects. The interpretation of the classification results is complicated by the fact that most wire segments are not spotless, but show a varying amount of anomalous features. Follow-up studies are needed to identify the exact nature of such features on wires.

physics.ins-det

GRANITE: High-Resolution Imaging and Electrical Qualification of Large-Area TPC Electrodes

Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for high-voltage performance of such an experiment, we have developed a scanning setup for comprehensive electrode quality assurance. The system is built around the GRANITE (Granular Robotic Assay for Novel Integrated TPC Electrodes) facility: a gantry robot on top of a $2.5\,\text{m}\times1.8\,\text{m}$ granite table, equipped with a suite of non-contact metrology devices. We developed a coaxial wire scanning head to measure and correlate localized high-voltage discharge currents in air with high-resolution surface images. We find that the identified discharge 'hotspots' are transient and show no significant correlation with static visual features. Next, we established a quantitative relationship between artificially induced abrasive surface damage on the wires and a reduction in the discharge inception voltage. This work provides a novel non-invasive tool for qualifying wires dedicated for use in electrodes for future low-background experiments.

physics.ins-det

Fast 3D 31P B1+ mapping with a weighted stack of spiral trajectory at 7 Tesla

Purpose: Phosphorus Magnetic Resonance Spectroscopy (31P MRS) enables non-invasive assessment of energy metabolism, yet its application is hindered by sensitivity limitations. To overcome this, often high magnetic fields are used, leading to challenges such as spatial B_1^+ inhomogeneity and therefore the need for accurate flip angle determination in accelerated acquisitions with short repetition times (T_R). In response to these challenges, we propose a novel short T_R and look-up table-based Double-Angle Method for fast 3D 31P B_1^+ mapping (fDAM). Methods: Our method incorporates 3D weighted stack of spiral gradient echo acquisitions and a frequency-selective pulse to enable efficient B_1^+ mapping based on the phosphocreatine signal at 7T. Protocols were optimised using simulations and validated through phantom experiments. The method was validated in phantom experiments and skeletal muscle applications using a birdcage 1H/31P volume coil. Results: The results of fDAM were compared to the classical DAM (cDAM). A good correlation (r=0.94) was obtained between the two B_1^+ maps. A 3D 31P B_1^+ mapping in the human calf muscle was achieved in about 10 min using a birdcage volume coil, with a 20% extended coverage relative to that of the cDAM (24 min). fDAM also enabled the first full brain coverage 31P 3D B_1^+ mapping in approx. 10 min using a 1 Tx/ 32 Rx coil. Conclusion: fDAM is an efficient method for 31P 3D B_1^+ mapping, showing promise for future applications in rapid 31P MRSI.

physics.med-ph

Twisted Pair Transmission Line Coil -- A Flexible, Self-Decoupled and Extremely Robust Element for 7T MRI

This study evaluates the performance of a twisted pair transmission line coil as a transceive element for 7T MRI in terms of physical flexibility, robustness to shape deformations, and interelement decoupling. Each coil element was created by shaping a twisted pair of wires into a circle. One wire was interrupted at the top, while the other was interrupted at the bottom, and connected to the matching circuit. Electromagnetic simulations were conducted to determine the optimal number of twists per length (in terms of B$_1^+$ field efficiency, SAR efficiency, sensitivity to elongation and interelement decoupling properties) and for investigating the fundamental operational principle of the coil through fields streamline visualization. A comparison between the twisted pair coil and a conventional loop coil in terms of B$_1^+$ fields, maxSAR10g, and stability of $S_{11}$ when the coil was deformed, was performed. Experimentally measured interelement coupling between individual elements of multichannel arrays was also investigated. Increasing the number of twists per length resulted in a more physically robust coil. Poynting vector streamline visualization showed that the twisted pair coil concentrated most of the energy in the near field. The twisted pair coil exhibited comparable B$_1^+$ fields and improved maxSAR10g to the conventional coil but demonstrated exceptional stability with respect to coil deformation and a strong self-decoupling nature when placed in an array configuration. The findings highlight the robustness of the twisted pair coil, showcasing its stability under shape variations. This coil holds great potential as a flexible RF coil for various imaging applications using multiple-element arrays, benefiting from its inherent decoupling.

physics.med-ph