Searcharxiv⌕ Search

arXiv subjects

David A. Nordsletten

Publications and source records attributed to David A. Nordsletten.

2 recordsLinked to original sources

In Silico Evaluation of Cardiac Tissue-Engineered Patch Interventions

Myocardial infarction significantly degrades heart function, and current treatments can bring forth serious cost and complications including blood clots and infections. To improve the current state of treatment, researchers are developing tissue patches from induced-pluripotent stem cells that can be incorporated into the heart, improving organ function after a myocardial infarction. These tissue patches include surface patches, attached to the epicardium of the heart, and thick transmural patches that replace the infarcted region. However, little is known about the impact of cardiac tissue patches on pump function in a patient's heart. In addition, it is not clear what patch structural properties - such as active stress generation, muscle fiber alignment, or material stiffness - may best augment existing heart tissue. Computational modeling can be used to examine different implementations and patch properties, illuminating the mechanical impact of cardiac tissue patches in the beating heart. In this work, we computationally implement different cardiac tissue patches to understand benefits of particular patch types and properties. We find that in transmural cardiac tissue patches, both activation and fiber alignment improve function. A transmural patch generating 10% of healthy active stress can increase stroke volume by 18%, and higher generated active stress in a circumferential muscle fiber orientation can recover stroke volume by over 50%. Furthermore, we find that surface cardiac tissue patches can enhance heart function slightly despite limiting diastolic filling, especially when fibrotic thinning has occurred. These conclusions identify broad design goals for the engineering of cardiac tissue patches to improve heart function after a myocardial infarction.

physics.med-ph↗

Comprehensive Analysis of Relative Pressure Estimation Methods Utilizing 4D Flow MRI

Magnetic resonance imaging (MRI) can estimate three-dimensional (3D) time-resolved relative pressure fields using 4D-flow MRI, thereby providing rich pressure field information. Clinical alternatives include catheterization and Doppler echocardiography, which only provide one-dimensional pressure drops. The accuracy of one-dimensional pressure drops derived from 4D-flow has been explored previously, but additional work is needed to evaluate the accuracy of 3D relative pressure field estimates. This work presents an analysis of three state-of-the-art relative pressure estimators: virtual Work-Energy Relative Pressure (vWERP), the Pressure Poisson Estimator (PPE), and the Stokes Estimator (STE). The spatiotemporal characteristics and sensitivity to noise were determined in silico. Estimators were then validated using a type B aortic dissection (TBAD) flow phantom with varying tear geometry and twelve catheter pressure measurements. Finally, the performance of each estimator was evaluated across eight patient cases. In silico pressure field errors were lower in STE compared to PPE, although PPE pressures were less noise sensitive. High velocity gradients and low spatial resolution contributed most significantly to local variations in 3D pressure field errors. Low temporal resolution lead to systematic underestimation of highly transient peak pressure events. In the flow phantom analysis, vWERP was the most accurate method, followed by STE and PPE. Each pressure estimator was strongly correlated with ground truth pressure values, despite the tendency to underestimate peak pressures. Patient case results demonstrated that each pressure estimator could be feasibly integrated into a clinical workflow.

physics.flu-dyn↗