SearcharxivSearch

arXiv subjects

David Balslev-Harder

Publications and source records attributed to David Balslev-Harder.

5 recordsLinked to original sources

Ctrl-A: Control-Driven Online Data Augmentation

We introduce ControlAugment (Ctrl-A), an automated data augmentation algorithm for image-vision tasks, which incorporates principles from control theory for online adjustment of augmentation strength distributions during model training. Ctrl-A eliminates the need for initialization of individual augmentation strengths. Instead, augmentation strength distributions are dynamically, and individually, adapted during training based on a control-loop architecture and what we define as relative operation response curves. Using an operation-dependent update procedure provides Ctrl-A with the potential to suppress augmentation styles that negatively impact model performance, alleviating the need for manually engineering augmentation policies for new image-vision tasks. Experiments on the CIFAR-10, CIFAR-100, and SVHN-core benchmark datasets using the common WideResNet-28-10 architecture demonstrate that Ctrl-A is highly competitive with existing state-of-the-art data augmentation strategies.

cs.CV

Versatile photoacoustic spectrometer based on a mid-infrared pulsed optical parametric oscillator

We demonstrate the usefulness of a nanosecond pulsed single-mode mid-infrared (MIR) optical parametric oscillator (OPO) for Photoacoustic (PA) spectroscopic measurements. The maximum wavelength ranges for the signal and idler are 1.4 um to 1.7 um and 2.8 um to 4.6 um, respectively, and with a MIR output power of up to 500 mW. Making the OPO useful for different spectroscopic PA trace-gas measurements targeting the major market opportunity of environmental monitoring and breath gas analysis. We perform spectroscopic measurements of methane (CH4) nitrogen dioxide (NO2) and ammonia (NH3) in the 2.8 um to 3.7 um wavelength region. The measurements were conducted with a constant flow rate of 300 ml/min, thus demonstrating the suitability of the gas sensor for real time trace gas measurements. The acquired spectra are compared with data from the Hitran database and good agreement is found. Demonstrating a resolution bandwidth of 1.5 1/cm. An Allan deviation analysis shows that the detection limit for methane at optimum integration time for the PA sensor is 8 ppbV (nmol/mol) at 105 seconds of integration time.

physics.app-ph

Designing and experimental verification of a photoacoustic flow sensor using computational fluid dynamics

A photoacoustic (PA) sensor for fast and real-time gas sensing is demonstrated. The PA sensor is a standalone system controlled by a Field-Programmable Gate Array (FPGA). The PA cell has been designed for flow noise immunity using computational fluid dynamics (CFD) analysis. The aim of the CFD analysis was to investigate and minimize the influence of the gas distribution and the flow noise on the PA signal. PA measurements were conducted at different flow rates by exciting molecular C-H stretch vibrational bands of hexane (C$_6$H$_{14}$) and decane (C$_{10}$H$_{22}$) molecules in clean air at 2950 cm$^{-1}$ (3.38 $μ$m) with a custom made mid-infrared interband cascade laser (ICL). We observe a (1$σ$, standard deviation) sensitivity of 0.4 $\pm0.1$ ppb (nmol/mol) for hexane in clean air at flow rates up to 1.7 L/min, corresponding to a normalized noise equivalent absorption (NNEA) coefficient of 2.5$\times 10^{-9}$ W cm$^{-1}$ Hz$^{-1/2}$, demonstrating high sensitivity and fast real-time gas analysis. An Allan deviation analysis for decane shows that the detection limit at optimum integration time is 0.25 ppbV (nmol/mol).

physics.ins-det

Photoacoustic spectroscopy of NO$_2$ using a mid-infrared pulsed optical parametric oscillator as light source

A photoacoustic (PA) sensor for spectroscopic measurements of NO$_2$-N$_2$ at ambient pressure and temperature is demonstrated. The PA sensor is pumped resonantly by a nanosecond pulsed single-mode mid-infrared (MIR) optical parametric oscillator (OPO). Spectroscopic measurements of NO$_2$-N$_2$ in the 3.25 $μ$m to 3.55 $μ$m wavelength region with a resolution bandwidth of 5 cm$^{-1}$ and with a single shot detection limit of 1.6 ppmV ($μ$mol/mol) is demonstrated. The measurements were conducted with a constant flow rate of 300 ml/min, thus demonstrating the suitability of the gas sensor for real time trace gas measurements. The acquired spectra is compared with data from the Hitran database and good agreement is found. An Allan deviation analysis shows that the detection limit at optimum integration time for the PAS sensor is 14 ppbV (nmol/mol) at 170 seconds of integration time, corresponding to a normalized noise equivalent absorption (NNEA) coefficient of 3.3$\times 10^{-7}$ W cm$^{-1}$ Hz$^{-1/2}$.

physics.app-ph

Phase-Sensitive Noise Suppression in a Photoacoustic Sensor based on Acoustic Circular Membrane Modes

A photoacoustic (PA) sensor based on higher order acoustic modes is demonstrated. The PA sensor is designed to enhance the gas-detection performance and simultaneously suppress ambient noise sources (e.g. flow noise, electrical noise and external acoustic noise). Two microphones are used and positioned such that the PA signals are ($π$) out of phase. Ambient acoustic noise are approximately in the same phase and will be subtracted and thus improve the SNR. In addition, by placing the gas in- and outlets so that the gas flows through the node of the first higher order membrane mode the coupling of flow noise is approximately 20 dB lower compared with flow through the fundamental mode at 5 L/min. The noise reduction and thus the increase in sensitivity is demonstrated by measuring vibrational lines of methanol and methane using a broadband interband cascade laser emitting radiation at 3.38 $μ$m. A signal-to-noise improvement of 20 (26 dB) using higher order modes are demonstrated compared with the fundamental mode. The maximum normalized noise equivalent absorption coefficient is 1.1 $\times 10^{-6}$ W cm$^{-1}$ Hz$^{1/2}$ for a flow of 5 L/min. It is anticipated that the noise cancelation strategy may find use in many practical industrial and environmental PA sensors, where ambient noise sources plays a crucial role for the absolute sensitive.

physics.optics