SearcharxivSearch

arXiv subjects

David E. McClelland

Publications and source records attributed to David E. McClelland.

At least 19 recordsLinked to original sources

Squeezing at the normal-mode splitting frequency of a nonlinear coupled cavity

Coupled optical cavities, which support normal modes, play a critical role in optical filtering, sensing, slow-light generation, and quantum state manipulation. Recent theoretical work has proposed incorporating nonlinear materials into these systems to enable novel quantum technologies. Here, we report the first experimental demonstration of squeezing generated in a quantum-enhanced coupled-cavity system, achieving a quantum noise reduction of 3.3 dB around the normal-mode splitting frequency of 7.47 MHz. We provide a comprehensive analysis of the system's loss mechanisms and performance limitations, validating theoretical predictions. Our results underscore the promise of coupled-cavity squeezers for advanced quantum applications, including gravitational wave detection and precision sensing.

quant-ph

Quantum Metrology for Gravitational Wave Astronomy

Einstein's General Theory of Relativity predicts that accelerating mass distributions produce gravitational radiation, analogous to electromagnetic radiation from accelerating charges. These gravitational waves have not been directly detected to date, but are expected to open a new window to the Universe in the near future. Suitable telescopes are kilometre-scale laser interferometers measuring the distance between quasi free-falling mirrors. Recent advances in quantum metrology may now provide the required sensitivity boost. So-called squeezed light is able to quantum entangle the high-power laser fields in the interferometer arms, and could play a key role in the realization of gravitational wave astronomy.

quant-ph

Quantum enhanced balanced heterodyne readout for differential interferometry

Conventional heterodyne readout schemes are now under reconsideration due to the realization of techniques to evade its inherent 3 dB signal-to-noise penalty. The application of high-frequency, spectrally entangled, two-mode squeezed states can further improve the readout sensitivity of audio-band signals. In this paper, we experimentally demonstrate quantum-enhanced heterodyne readout of two spatially distinct interferometers with direct optical signal combination, circumventing the 3 dB heterodyne signal-to-noise penalty. Applying a high-frequency, spectrally entangled, two-mode squeezed state, we show further signal-to-noise improvement of an injected audio band signal of 3.5 dB. This technique is applicable for quantum-limited high-precision experiments, with application to searches for quantum gravity, gravitational wave detection and wavelength-multiplexed quantum communication.

quant-ph

Multi-messenger astronomy with a Southern-Hemisphere gravitational-wave observatory

Joint observations of gravitational waves and electromagnetic counterparts will answer questions about cosmology, gamma-ray bursts, and the behaviour of matter at supranuclear densities. The addition of a Southern-Hemisphere gravitational-wave observatory to proposed global networks creates a longer baseline, which is beneficial for sky localisation. We analyse how an observatory in Australia can enhance the multi-messenger astronomy capabilities of future networks. We estimate the number of binary neutron star mergers with joint observations of gravitational waves and kilonova counterparts detectable by the Vera C. Rubin Observatory. First, we consider a network of upgrades to current observatories. Adding an Australian observatory to a three-observatory network (comprising two observatories in the USA and one in Europe) boosts the rate of joint observations from $2.5^{+4.5}_{-2.0}$ per year to $5.6^{+10}_{-4.5}$ per year (a factor of two improvement). Then, we consider a network of next-generation observatories. Adding a $20$ km Australian observatory to a global network of a Cosmic Explorer $40$ km in the USA and an Einstein Telescope in Europe only marginally increases the rate from $40^{+71}_{-32}$ per year to $44^{+79}_{-35}$ per year (a factor of 1.1 improvement). The addition of an Australian observatory, however, ensures that at least two observatories are online far more often. When the Cosmic Explorer $40$ km is offline for a major upgrade, the Australian observatory increases the joint observation rate from $0.5^{+0.8}_{-0.4}$ per year to $38^{+68}_{-30}$ per year (a factor of 82 improvement). When the Einstein Telescope is offline, the joint observation rate increases from $0.2^{+0.3}_{-0.1}$ per year to $19^{+34}_{-15}$ per year (a factor of 113 improvement). We sketch out the broader science case for a Southern-Hemisphere gravitational-wave observatory.

gr-qc

Nondegenerate internal squeezing: an all-optical, loss-resistant quantum technique for gravitational-wave detection

The detection of kilohertz-band gravitational waves promises discoveries in astrophysics, exotic matter, and cosmology. To improve the kilohertz quantum noise-limited sensitivity of interferometric gravitational-wave detectors, we investigate nondegenerate internal squeezing: optical parametric oscillation inside the signal-recycling cavity with distinct signal-mode and idler-mode frequencies. We use an analytic Hamiltonian model to show that this stable, all-optical technique is tolerant to decoherence from optical detection loss and that it, with its optimal readout scheme, is feasible for broadband sensitivity enhancement.

quant-ph

Generation and control of frequency dependent squeezing via EPR entanglement

The Standard Quantum Limit (SQL) in interferometric displacement measurement imposes a restriction on the precision of the measurement due to its quantum back-action noise. This limit can be surpassed over a broad frequency band by injecting squeezed vacuum states with a frequency dependent (FD) quadrature angle into the measurement system. Here, we demonstrate the generation of FD squeezed vacuum states by utilizing Einstein-Podolsky-Rosen (EPR) entangled states. The frequency dependence of the squeezed state can be tuned by conditionally filtering the measurement once the two entangled fields are detected. A stable control scheme for the method is demonstrated which can be implemented in future gravitational-wave detectors to improve their astronomical reach.

quant-ph

Broadband reduction of quantum radiation pressure noise via squeezed light injection

We present the reduction and manipulation of quantum radiation pressure noise (QRPN) in an optomechanical cavity with the injection of squeezed light. The optomechanical system consists of a high-reflectivity single-crystal microresonator which serves as one mirror of a Fabry-Perot cavity. The experiment is performed at room temperature and is QRPN dominated between 10 kHz and 50 kHz, frequencies relevant to gravitational wave observatories. We observed a reduction of 1.2 dB in the measurement noise floor with the injection of amplitude squeezed light generated from a below-threshold degenerate optical parametric oscillator. This experiment is a crucial step in realizing the reduction of QRPN for future interferometric gravitational wave detectors and improving their sensitivity.

quant-ph

Observation of squeezed light in the 2 $\mathrm{μm}$ region

We present the generation and detection of squeezed light in the 2 $\mathrm{μm}$ wavelength region. This experiment is a crucial step in realising the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically-poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilised 1984 nm thulium fibre laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured $4.0 \pm 0.1$ dB of squeezing and $10.5 \pm 0.5$ dB of anti-squeezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.

physics.ins-det

Radiation-Pressure-Mediated Control of an Optomechanical Cavity

We describe and demonstrate a method to control a detuned movable-mirror Fabry-Perot cavity using radiation pressure in the presence of a strong optical spring. At frequencies below the optical spring resonance, self-locking of the cavity is achieved intrinsically by the optomechanical (OM) interaction between the cavity field and the movable end mirror. The OM interaction results in a high rigidity and reduced susceptibility of the mirror to external forces. However, due to a finite delay time in the cavity, this enhanced rigidity is accompanied by an anti-damping force, which destabilizes the cavity. The cavity is stabilized by applying external feedback in a frequency band around the optical spring resonance. The error signal is sensed in the amplitude quadrature of the transmitted beam with a photodetector. An amplitude modulator in the input path to the cavity modulates the light intensity to provide the stabilizing radiation pressure force.

quant-ph

Control and tuning of a suspended Fabry-Perot cavity using digitally-enhanced heterodyne interferometry

We present the first demonstration of real-time closed-loop control and deterministic tuning of an independently suspended Fabry-Perot optical cavity using digitally-enhanced heterodyne interferometry, realising a peak sensitivity of $\sim$10 pm$/\sqrt{\mathrm{Hz}}$ over the 10-1000 Hz frequency band. The methods presented are readily extensible to multiple coupled cavities. As such, we anticipate that refinements of this technique may find application in future interferometric gravitational-wave detectors.

physics.optics

LISA pathfinder appreciably constrains collapse models

LISA Pathfinder's measurement of a relative acceleration noise between two free-falling test masses with a square root of the power spectral density of $5.2 \pm 0.1 \mbox{ fm s}^{-2}/\sqrt{\rm{Hz}}$ appreciably constrains collapse models. In particular, we bound the localization rate parameter, $λ_{\rm CSL}$, in the continuous spontaneous localization model (CSL) to be at most $\left( 2.96 \pm 0.12 \right) \times 10^{-8} \mbox{ s}^{-1}$. Moreover, we bound the regularization scale, $σ_{\rm DP}$, used in the Diosi-Penrose (DP) model to be at least $40.1 \pm 0.5 \mbox{ fm}$. These bounds significantly constrain the validity of these models. In particular: (i) a lower bound of $2.2 \times 10^{-8\pm2} \mbox{s}^{-1}$ for $λ_{\rm CSL}$ has been proposed in (although a lower bound of about $10^{-17} \mbox{s}^{-1}$ is sometimes used), in order for the collapse noise to be substantial enough to explain the phenomenology of quantum measurement, and (ii) 40 fm is larger than the size of any nucleus, while the regularization scale has been proposed to be the size of the nucleus.

quant-ph

Measurable signatures of quantum mechanics in a classical spacetime

We propose an optomechanics experiment that can search for signatures of a fundamentally classical theory of gravity and in particular of the many-body Schroedinger-Newton (SN) equation, which governs the evolution of a crystal under a self-gravitational field. The SN equation predicts that the dynamics of a macroscopic mechanical oscillator's center of mass wavefunction differ from the predictions of standard quantum mechanics. This difference is largest for low-frequency oscillators, and for materials, such as Tungsten or Osmium, with small quantum fluctuations of the constituent atoms around their lattice equilibrium sites. Light probes the motion of these oscillators and is eventually measured in order to extract valuable information on the pendulum's dynamics. Due to the non-linearity contained in the SN equation, we analyze the fluctuations of measurement results differently than standard quantum mechanics. We revisit how to model a thermal bath, and the wavefunction collapse postulate, resulting in two prescriptions for analyzing the quantum measurement of the light. We demonstrate that both predict features, in the outgoing light's phase fluctuations' spectrum, which are separate from classical thermal fluctuations and quantum shot noise, and which can be clearly resolved with state of the art technology.

quant-ph

Thermal noise of gram-scale cantilever flexures

We present measurements of thermal noise in niobium and aluminium flexures. Our measurements cover the audio frequency band from 10Hz to 10kHz, which is of particular relevance to ground-based interferometric gravitational wave detectors, and span up to an order of magnitude above and below the fundamental flexure resonances at 50Hz - 300Hz. Our results are well-explained by a simple model in which both structural and thermoelastic loss play a role. The ability of such a model to explain this interplay is important for investigations of quantum-radiation-pressure noise and the standard quantum limit.

physics.ins-det

Arm-length stabilisation for interferometric gravitational-wave detectors using frequency-doubled auxiliary lasers

Residual motion of the arm cavity mirrors is expected to prove one of the principal impediments to systematic lock acquisition in advanced gravitational-wave interferometers. We present a technique which overcomes this problem by employing auxiliary lasers at twice the fundamental measurement frequency to pre-stabilise the arm cavities' lengths. Applying this approach, we reduce the apparent length noise of a 1.3 m long, independently suspended Fabry-Perot cavity to 30 pm rms and successfully transfer longitudinal control of the system from the auxiliary laser to the measurement laser.

physics.ins-det

Numerical wave optics and the lensing of gravitational waves by globular clusters

We consider the possible effects of gravitational lensing by globular clusters on gravitational waves from asymmetric neutron stars in our galaxy. In the lensing of gravitational waves, the long wavelength, compared with the usual case of optical lensing, can lead to the geometrical optics approximation being invalid, in which case a wave optical solution is necessary. In general, wave optical solutions can only be obtained numerically. We describe a computational method that is particularly well suited to numerical wave optics. This method enables us to compare the properties of several lens models for globular clusters without ever calling upon the geometrical optics approximation, though that approximation would sometimes have been valid. Finally, we estimate the probability that lensing by a globular cluster will significantly affect the detection, by ground-based laser interferometer detectors such as LIGO, of gravitational waves from an asymmetric neutron star in our galaxy, finding that the probability is insignificantly small.

gr-qc

Quantum Noise Locking

Quantum optical states which have no coherent amplitude, such as squeezed vacuum states, can not rely on standard readout techniques to generate error signals for control of the quadrature phase. Here we investigate the use of asymmetry in the quadrature variances to obtain a phase-sensitive readout and to lock the phase of a squeezed vacuum state, a technique which we call noise locking (NL). We carry out a theoretical derivation of the NL error signal and the associated stability of the squeezed and anti-squeezed lock points. Experimental data for the NL technique both in the presence and absence of coherent fields are shown, including a comparison with coherent locking techniques. Finally, we use NL to enable a stable readout of the squeezed vacuum state on a homodyne detector.

quant-ph

Demonstration of a passive sub-picostrain fiber strain sensor

We demonstrate a fiber Fabry-Perot (FFP) sensor capable of detecting sub-picostrain signals, from 100 Hz and extending beyond 100 kHz, using the Pound-Drever-Hall frequency locking technique. A low power diode laser at 1550 nm is locked to a free-space reference cavity to suppress its free-running frequency noise, thereby stabilizing the laser. The stabilized laser is then used to interrogate a FFP where the PDH error signal yields the instantaneous fiber strain.

physics.optics

Pump-probe differencing technique for cavity-enhanced, noise-canceling saturation laser spectroscopy

We present an experimental technique enabling mechanical-noise free, cavity-enhanced frequency measurements of an atomic transition and its hyperfine structure. We employ the 532nm frequency doubled output from a Nd:YAG laser and an iodine vapour cell. The cell is placed in a traveling-wave Fabry-Perot interferometer (FPI) with counter-propagating pump and probe beams. The FPI is locked using the Pound-Drever-Hall (PDH) technique. Mechanical noise is rejected by differencing pump and probe signals. In addition, this differenced error signal gives a sensitive measure of differential non-linearity within the FPI.

physics.optics