Searcharxiv⌕ Search

arXiv subjects

David Huang

Publications and source records attributed to David Huang.

22 records · Page 2Linked to original sources

Interpretable Diabetic Retinopathy Diagnosis based on Biomarker Activation Map

Deep learning classifiers provide the most accurate means of automatically diagnosing diabetic retinopathy (DR) based on optical coherence tomography (OCT) and its angiography (OCTA). The power of these models is attributable in part to the inclusion of hidden layers that provide the complexity required to achieve a desired task. However, hidden layers also render algorithm outputs difficult to interpret. Here we introduce a novel biomarker activation map (BAM) framework based on generative adversarial learning that allows clinicians to verify and understand classifiers decision-making. A data set including 456 macular scans were graded as non-referable or referable DR based on current clinical standards. A DR classifier that was used to evaluate our BAM was first trained based on this data set. The BAM generation framework was designed by combing two U-shaped generators to provide meaningful interpretability to this classifier. The main generator was trained to take referable scans as input and produce an output that would be classified by the classifier as non-referable. The BAM is then constructed as the difference image between the output and input of the main generator. To ensure that the BAM only highlights classifier-utilized biomarkers an assistant generator was trained to do the opposite, producing scans that would be classified as referable by the classifier from non-referable scans. The generated BAMs highlighted known pathologic features including nonperfusion area and retinal fluid. A fully interpretable classifier based on these highlights could help clinicians better utilize and verify automated DR diagnosis.

eess.IV↗

Focal Loss Analysis of Nerve Fiber Layer Reflectance for Glaucoma Diagnosis

Purpose: To evaluate nerve fiber layer (NFL) reflectance for glaucoma diagnosis. Methods: Participants were imaged with 4.5X4.5-mm volumetric disc scans using spectral-domain optical coherence tomography (OCT). The normalized NFL reflectance map was processed by an azimuthal filter to reduce directional reflectance bias due to variation of beam incidence angle. The peripapillary area of the map was divided into 160 superpixels. Average reflectance was the mean of superpixel reflectance. Low-reflectance superpixels were identified as those with NFL reflectance below the 5 percentile normative cutoff. Focal reflectance loss was measure by summing loss in low-reflectance superpixels. Results: Thirty-five normal, 30 pre-perimetric and 35 perimetric glaucoma participants were enrolled. Azimuthal filtering improved the repeatability of the normalized NFL reflectance, as measured by the pooled superpixel standard deviation (SD), from 0.73 to 0.57 dB (p<0.001, paired t-test) and reduced the population SD from 2.14 to 1.78 dB (p<0.001, t-test). Most glaucomatous reflectance maps showed characteristic patterns of contiguous wedge or diffuse defects. Focal NFL reflectance loss had significantly higher diagnostic sensitivity than the best NFL thickness parameter (overall, inferior, or focal loss volume): 53% v. 23% (p=0.027) in PPG eyes and 100% v. 80% (p=0.023) in PG eyes, with the specificity fixed at 99%. Conclusions: Azimuthal filtering reduces the variability of NFL reflectance measurements. Focal NFL reflectance loss has excellent glaucoma diagnostic accuracy compared to the standard NFL thickness parameters. The reflectance map may be useful for localizing NFL defects.

eess.IV↗

Near-infrared laser thermal conjunctivoplasty

Conjunctivochalasis is a common cause of tear dysfunction due to the conjunctiva becoming loose and wrinkly with age. The current solutions to this disease include either surgical excision in the operating room, or thermoreduction of the loose tissue with hot wire in the clinic. We developed a near-infrared (NIR) laser thermal conjunctivoplasty (LTC) system, which gently shrinks the redundant tissue. The NIR light is mainly absorbed by water, so the heating is even and there is no bleeding. The system utilizes a 1460-nm programmable laser diode system as a light source. A miniaturized handheld probe delivers the laser light and focuses the laser into a 10x1 mm2 line. A foot pedal is used to deliver a preset number of calibrated laser pulses. A fold of loose conjunctiva is grasped by a pair of forceps. The infrared laser light is delivered through an optical fiber and a laser line is focused exactly on the conjunctival fold by a cylindrical lens. Ex vivo experiments using porcine eye were performed with the optimal laser parameters. It was found that up to 50% of conjunctiva shrinkage could be achieved.

physics.med-ph↗

Polarization-multiplexed, dual-beam swept source optical coherence tomography angiography

A polarization-multiplexed, dual-beam setup is proposed to expand the field of view for a swept source optical coherence tomography angiography (OCTA) system. This method used a Wollaston prism to split sample path light into two orthogonal-polarized beams. This allowed two beams to shine on the cornea at an angle separation of ~ 14 degrees, which led to a separation of ~ 4.2 mm on the retina. A 3-mm glass plate was inserted into one of the beam paths to set a constant path length difference between the two polarized beams so the interferogram from the two beams are coded at different frequency bands. The resulting OCTA images from the two beams were coded with a depth separation of ~ 2 mm. 5x5 mm2 angiograms from the two beams were obtained simultaneously in 4 seconds. The two angiograms then were montaged to get a wider field of view (FOV) of ~ 5x9.2 mm2.

physics.med-ph↗