SearcharxivSearch

arXiv subjects

David J. Thoen

Publications and source records attributed to David J. Thoen.

At least 19 recordsLinked to original sources

Post-fabrication trimming of a 1024-pixel, single-photon counting, Microwave Kinetic Inductance Detector array with a pixel pitch of 150 micron

Microwave Kinetic Inductance Detectors are superconducting resonators capable of single-photon counting with energy resolving capability at visible and near-infrared wavelengths. Their zero read noise, extremely low dark counts, and compatibility with frequency-division multiplexing make them well suited for large imaging arrays. The detector yield of these arrays is often limited by the fabrication-induced frequency scatter leading to resonator collisions. We find that the tight packing of the pixels can add significant frequency scatter as well. We developed a post-fabrication correction method that is suitable for tightly packed arrays with a pixel pitch of $150\ \mathrm{μm}$. We demonstrate this method on a 1024-pixel array multiplexed on a single octave of readout bandwidth and show a reduction in frequency scatter from $1.1\times 10^{-2}$ to $3.5\times 10^{-4}$ and an increase in yield from $76\%$ to $94\%$.

physics.ins-det

Coupled-Mode Equations with Arbitrary Mode Combinations for Kinetic-Inductance Superconducting Traveling-Wave Parametric Devices: Theory and Experimental Validation

The coupled-mode equations (CMEs) have proven very successful in describing parametric processes in nonlinear optics. More recently, the same formulation has been used to model microwave superconducting parametric amplifiers and frequency multipliers. However, when applied to the microwave regime, not all assumptions remain valid and losses play a more dramatic role. Here, we revisit the CMEs applied to traveling-wave superconducting amplifiers to include losses and provide a formulation that enables their systematic derivation for any combination of traveling waves. As examples, we discuss the impact of unwanted harmonics and intermodulation products on parametric amplification, as well as harmonic generation. We verify that, if not properly accounted for, device performance can deviate considerably from the ideal case. Furthermore, using a superconducting CPW-based artificial transmission line and combining an independent experimental determination of its nonlinear parameter $I'_*$ with simulations of its linear properties, we obtain a parameter-free validation of this formulation. The nonlinear parameter was determined to be $I'_* \approx 27$ mA which, surprisingly, scales with the theoretical depairing current and not with the much smaller critical current of the device. For the validation, we measured multiple-harmonic generation and found excellent agreement between theory and experiment. The fact that $I'_* \gg I_C$ has direct implications for device design.

physics.app-ph

Development of TIFUUN: Terahertz Integral Field Units with Universal Nanotechnology

TIFUUN (THz Integral Field Units with Universal Nanotechnology) is an ultra-wideband mm-submm wave imaging spectrometer that capitalizes on the highly scalable integrated superconducting spectrometer technology. TIFUUN has two slots for integral field units (IFUs), which can jointly be optimized as open-hardware for each astronomical observation in terms of spatial and spectral coverage. These IFUs can have observation frequencies in the range of 90--360 GHz, with spectral resolution up to $R\equiv F/ΔF \le 1,000$, with up to $\sim$18,000 kinetic inductance detectors (shared by the two IFUs with a flexible ratio). The ultra-wide 4:1 (2 octave) bandwidth optics fits in a remarkably compact volume, by means of thin silicon lenses and a high chief ray angle design. The first pair of IFUs are being developed for the SUBLIME (Study of the Universe By Line Intensity Mapping Experiments) experiment that aims to map CII emission at redshift $\sim$6 to trace the cosmic large-scale structure and the buildup of galaxies during reionization, using TIFUUN on the ASTE 10-m telescope. The scalability, flexibility and compactness makes TIFUUN a highly compatible and portable system suited also for upcoming telescope facilities in the vicinity, such as FYST and AtLAST/LST.

astro-ph.IM

A High Efficiency Superconducting On-chip Filterbank with Directional Filters for Integral Field Units in the Sub-millimeter Regime

Integrated superconducting spectrometers are developing to the point that they are enabling integral field units, providing large area spectral mapping capabilities for astronomy in the sub-millimeter band. However, these integral field units are only worthwhile if they have a high efficiency, but to date the efficiency of on-chip filterbanks has been quite poor. Here we demonstrate a filterbank with high efficiency by using directional filters. Using a cryogenic thermal load and a noise measurement in combination with a continuous-wave terahertz source to obtain the spectral response of the filters, we are able to accurately measure the filterbank efficiency, accounting for all quasi-optical elements within our setup. We experimentally obtain an average peak coupling efficiency to the detectors of 75% in a filterbank that sparsely samples between 125 GHz to 220 GHz using filters with a mean loaded quality factor of 19.6. Our results demonstrate that a filterbank with a high efficiency is achievable using directional filters, giving a clear route towards efficient integral field units.

physics.ins-det

Demonstrating Single Photon Counting with Kinetic Inductance Detectors from 3.8 to 25 $μ$m

One of the primary objectives of modern astronomy is the atmospheric characterization of Earth-like exoplanets at visible and infrared wavelengths. Achieving this goal requires extremely sensitive detectors capable of measuring faint signal of the exoplanet at the single-photon level while maintaining near-zero dark count rates. In the infrared, however, conventional semiconducting detector technologies struggle to meet these stringent requirements. In this work we demonstrate single-photon counting with superconducting Microwave Kinetic Inductance Detectors at the wavelengths 3.8, 8.5, 18.5, and 25 $μ$m and measure resolving powers ($E/δE$) of 9.9, 5.9, 3.2, and 3.3, respectively, with corresponding dark count rates of 4, 8, 34, and 48 mHz. Our membrane-based devices reach phonon-loss limited performance at 3.8 $μ$m, more than doubling the performance attainable with comparable solid-substrate devices. These results showcase the detector technology in the mid-infrared and the intricate measurement setup required for these sensitive detectors. We discuss how the detector design and measurement setup can be further optimized to increase the detector performance in the mid-infrared.

astro-ph.IM

Recombination of localized quasiparticles in disordered superconductors

Disordered superconductors offer new impedance regimes for quantum circuits, enable a pathway to protected qubits, and can improve superconducting detectors due to their high kinetic inductance and sheet resistance. The performance of these devices can be limited, however, by quasiparticles - the fundamental excitations of a superconductor. While experiments have shown that disorder affects the relaxation of quasiparticles drastically, the microscopic mechanisms are still not understood. We address this issue by measuring quasiparticle relaxation in a disordered $β$-Ta film, which we pattern as the inductor of a microwave resonator. We observe that quasiparticle recombination is governed by the phonon scattering time, which is faster than conventional recombination in ordered superconductors. We interpret the results as recombination of localized quasiparticles, induced by disorder, which first delocalize via phonon absorption. We analyze quasiparticle relaxation measurements on superconductors with different degrees of disorder and conclude that this phenomenon is inherent to disordered superconductors.

cond-mat.supr-con

Volume dependence of microwave induced excess quasiparticles in superconducting resonators

The presence of quasiparticles typically degrades the performance of superconducting microwave circuits. The readout signal can generate non-equilibrium quasiparticles, which lead to excess microwave loss and decoherence. To understand this effect quantitatively, we measure quasiparticle fluctuations and extract the quasiparticle density across different temperatures, readout powers, and resonator volumes. We find that microwave power generates a higher quasiparticle density as the active resonator volume is reduced and show that this effect sets a sensitivity limit on kinetic inductance detectors. We compare our results with theoretical models of direct microwave photon absorption by quasiparticles and conclude that an unknown, indirect mechanism plays a dominant role in quasiparticle generation. These results provide a route to mitigate quasiparticle generation due to readout power in superconducting devices.

cond-mat.supr-con

Lens based Kinetic Inductance Detectors with Distributed Dual Polarised Absorbers for Far Infra-red Space-based Astronomy

Future space-based far infra-red astronomical observations require background limited detector sensitivities and scalable focal plane array solutions to realise their vast potential in observation speed. In this work, a focal plane array of lens absorber coupled Kinetic Inductance Detectors (KIDs) is proposed to fill this role. The figures of merit and design guidelines for the proposed detector concept are derived by employing a previously developed electromagnetic spectral modelling technique. Two designs operating at central frequencies of $6.98$ and $12$ THz are studied. A prototype array of the former is fabricated, and its performance is experimentally determined and validated. Specifically, the optical coupling of the detectors to incoherent distributed sources (i.e. normalised throughput) is quantified experimentally with good agreement with the estimations provided by the model. The coupling of the lens absorber prototypes to an incident plane wave, i.e. aperture efficiency, is also indirectly validated experimentally matching the expected value of $54\%$ averaged over two polarisation. The noise equivalent power of the KIDs are also measured with limiting value of $8\times10^{-20}$ $\mathrm{W/\sqrt{Hz}}$.

astro-ph.IM

Commissioning the CMB polarization telescope GroundBIRD with the full set of detectors

GroundBIRD is a ground-based cosmic microwave background (CMB) experiment for observing the polarization pattern imprinted on large angular scales ($\ell > 6$ ) from the Teide Observatory in Tenerife, Spain. Our primary scientific objective is a precise measurement of the optical depth $τ$ ($σ(τ) \sim 0.01$) to the reionization epoch of the Universe to cross-check systematic effects in the measurements made by previous experiments. GroundBIRD observes a wide sky area in the Northern Hemisphere ($\sim 40\%$ of the full sky) while continuously rotating the telescope at a high speed of up to 20 rotations per minute (rpm) to overcome the fluctuations of atmospheric radiation. We have adopted the NbTiN/Al hybrid microwave kinetic inductance detectors (MKIDs) as focal plane detectors. We observe two frequency bands centered at 145 GHz and 220 GHz. The 145 GHz band picks up the peak frequency of the CMB spectrum. The 220 GHz band helps accurate removal of the contamination of thermal emission from the Galactic interstellar dust. The MKID arrays (138 MKIDs for 145GHz and 23 MKIDs for 220GHz) were designed and optimized so as to minimize the contamination of the two-level-system noise and maximize the sensitivity. The MKID arrays were successfully installed in May 2023 after the performance verification tests were performed at a laboratory. GroundBIRD has been upgraded to use the full MKID arrays, and scientific observations are now underway. The telescope is automated, so that all observations are performed remotely. Initial validations, including polarization response tests and observations of Jupiter and the moon, have been completed successfully. We are now running scientific observations.

astro-ph.IM

Resolving Power of Visible to Near-Infrared Hybrid $β$-Ta/NbTiN Kinetic Inductance Detectors

Kinetic Inductance Detectors (KIDs) are superconducting energy-resolving detectors, sensitive to single photons from the near-infrared to ultraviolet. We study a hybrid KID design consisting of a beta phase tantalum ($β$-Ta) inductor and a NbTiN interdigitated capacitor (IDC). The devices show an average intrinsic quality factor $Q_i$ of 4.3$\times10^5$ $\pm$ 1.3 $\times10^5$. To increase the power captured by the light sensitive inductor, we 3D-print an array of 150$\times$150 $μ$m resin micro lenses on the backside of the sapphire substrate. The shape deviation between design and printed lenses is smaller than 1$μ$m, and the alignment accuracy of this process is $δ_x = +5.8 \pm 0.5$ $μ$m and $δ_y = +8.3 \pm 3.3$ $μ$m. We measure a resolving power for 1545-402 nm that is limited to 4.9 by saturation in the KID's phase response. We can model the saturation in the phase response with the evolution of the number of quasiparticles generated by a photon event. An alternative coordinate system that has a linear response raises the resolving power to 5.9 at 402 nm. We verify the measured resolving power with a two-line measurement using a laser source and a monochromator. We discuss several improvements that can be made to the devices on a route towards KID arrays with high resolving powers.

physics.ins-det

DESHIMA 2.0: development of an integrated superconducting spectrometer for science-grade astronomical observations

Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed to observe the 220-440 GHz band in a single shot, corresponding to a redshift range of $z$=3.3-7.6 for the ionized carbon emission ([C II] 158 $μ$m). The first-light experiment of DESHIMA 1.0, using the 332-377 GHz band, has shown an excellent agreement among the on-sky measurements, the lab measurements, and the design. As a successor to DESHIMA 1.0, we plan the commissioning and the scientific observation campaign of DESHIMA 2.0 on the ASTE 10-m telescope in 2023. Ongoing upgrades for the full octave-bandwidth system include the wideband 347-channel chip design and the wideband quasi-optical system. For efficient measurements, we also develop the observation strategy using the mechanical fast sky-position chopper and the sky-noise removal technique based on a novel data-scientific approach. In the paper, we show the recent status of the upgrades and the plans for the scientific observation campaign.

astro-ph.IM

Strong Reduction of Quasiparticle Fluctuations in a Superconductor due to Decoupling of the Quasiparticle Number and Lifetime

We measure temperature dependent quasiparticle fluctuations in a small Al volume, embedded in a NbTiN superconducting microwave resonator. The resonator design allows for read-out close to equilibrium. By placing the Al film on a membrane, we enhance the fluctuation level and separate quasiparticle from phonon effects. When lowering the temperature, the recombination time saturates and the fluctuation level reduces a factor $\sim$100. From this we deduce that the number of free quasiparticles is still thermal. Therefore, the theoretical, inverse relation between quasiparticle number and recombination time is invalid in this experiment. This is consistent with quasiparticle trapping, where on-trap recombination limits the observed quasiparticle lifetime.

cond-mat.supr-con

Terahertz Band-Pass Filters for Wideband Superconducting On-chip Filter-bank Spectrometers

A superconducting microstrip half-wavelength resonator is proposed as a suitable band-pass filter for broadband moderate spectral resolution spectroscopy for terahertz (THz) astronomy. The proposed filter geometry has a free spectral range of an octave of bandwidth without introducing spurious resonances, reaches a high coupling efficiency in the pass-band and shows very high rejection in the stop-band to minimize reflections and cross-talk with other filters. A spectrally sparse prototype filter-bank in the band 300-400 GHz has been developed employing these filters as well as an equivalent circuit model to anticipate systematic errors. The fabricated chip has been characterized in terms of frequency response, reporting an average peak coupling efficiency of 27% with an average spectral resolution of 940.

astro-ph.IM

Phonon-trapping enhanced energy resolution in superconducting single photon detectors

A noiseless, photon counting detector, which resolves the energy of each photon, could radically change astronomy, biophysics and quantum optics. Superconducting detectors promise an intrinsic resolving power at visible wavelengths of $R=E/δE\approx100$ due to their low excitation energy. We study superconducting energy-resolving Microwave Kinetic Inductance Detectors (MKIDs), which hold particular promise for larger cameras. A visible/near-infrared photon absorbed in the superconductor creates a few thousand quasiparticles through several stages of electron-phonon interaction. Here we demonstrate experimentally that the resolving power of MKIDs at visible to near-infrared wavelengths is limited by the loss of hot phonons during this process. We measure the resolving power of our aluminum-based detector as a function of photon energy using four lasers with wavelengths between $1545-402$ nm. For detectors on thick SiN/Si and sapphire substrates the resolving power is limited to $10-21$ for the respective wavelengths, consistent with the loss of hot phonons. When we suspend the sensitive part of the detector on a 110 nm thick SiN membrane, the measured resolving power improves to $19-52$ respectively. The improvement is equivalent to a factor $8\pm2$ stronger phonon trapping on the membrane, which is consistent with a geometrical phonon propagation model for these hot phonons. We discuss a route towards the Fano limit by phonon engineering.

astro-ph.IM

Direct evidence for Cooper pairing without a spectral gap in a disordered superconductor above $T_{C}$

The idea that preformed Cooper pairs could exist in a superconductor above its zero-resistance state has been explored for unconventional, interface, and disordered superconductors, yet direct experimental evidence is lacking. Here, we use scanning tunneling noise spectroscopy to unambiguously show that preformed Cooper pairs exist up to temperatures much higher than the zero-resistance critical temperature $T_{C}$ in the disordered superconductor titanium nitride, by observing a clear enhancement in the shot noise that is equivalent to a change of the effective charge from 1 to 2 electron charges. We further show that spectroscopic gap fills up rather than closes when increasing temperature. Our results thus demonstrate the existence of a novel state above $T_{C}$ that, much like an ordinary metal, has no (pseudo)gap, but carries charge via paired electrons.

cond-mat.supr-con

Characterization of low-loss hydrogenated amorphous silicon films for superconducting resonators

Superconducting resonators used in millimeter-submillimeter astronomy would greatly benefit from deposited dielectrics with a small dielectric loss. We deposited hydrogenated amorphous silicon films using plasma-enhanced chemical vapor deposition, at substrate temperatures of 100°C, 250°C and 350°C. The measured void volume fraction, hydrogen content, microstructure parameter, and bond-angle disorder are negatively correlated with the substrate temperature. All three films have a loss tangent below $10^{-5}$ for a resonator energy of $10^5$ photons, at 120 mK and 4-7 GHz. This makes these films promising for microwave kinetic inductance detectors and on-chip millimeter-submilimeter filters.

astro-ph.IM

Simulating the radiation loss of superconducting submillimeter wave filters and transmission lines using Sonnet EM

Superconducting resonators and transmission lines are fundamental building blocks of integrated circuits for millimeter-submillimeter astronomy. Accurate simulation of radiation loss from the circuit is crucial for the design of these circuits because radiation loss increases with frequency, and can thereby deteriorate the system performance. Here we show a stratification for a 2.5-dimensional method-of-moment simulator Sonnet EM that enables accurate simulations of the radiative resonant behavior of submillimeter-wave coplanar resonators and straight coplanar waveguides (CPWs). The Sonnet simulation agrees well with the measurement of the transmission through a coplanar resonant filter at 374.6 GHz. Our Sonnet stratification utilizes artificial lossy layers below the lossless substrate to absorb the radiation, and we use co-calibrated internal ports for de-embedding. With this type of stratification, Sonnet can be used to model superconducting millimeter-submillimeter wave circuits even when radiation loss is a potential concern.

astro-ph.IM

DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated Superconducting Spectrometer

We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope. We established a responsivity model that converts frequency responses of the MKIDs to line-of-sight brightness temperature. We estimated two parameters of the responsivity model using a set of skydip data taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for each MKID. The line-of-sight brightness temperature of sky is estimated using an atmospheric transmission model and the PWVs. As a result, we obtain an average temperature calibration uncertainty of $1σ=4$%, which is smaller than other photometric biases. In addition, the average forward efficiency of 0.88 in our responsivity model is consistent with the value expected from the geometrical support structure of the telescope. We also estimate line-of-sight PWVs of each skydip observation using the frequency response of MKIDs, and confirm the consistency with PWVs reported by the Atacama Large Millimeter/submillimeter Array.

astro-ph.IM