Development and validation of a measurement-driven inter crystal scatter recovery algorithm with in-system calibration

In PET a high percentage of gamma photons being detected undergo Compton scattering in the scintillator. Scintillator blocks are often built from optically isolated crystals. Depending on the angle of incidence and the scintillator geometry this might lead to inter crystal scatter (ICS) events, where energy is deposited in two or more crystals in the detector, which common positioning and reconstruction algorithms cannot resolve. Therefore, ICS events worsen the spatial resolution and the signal-to-noise ratio in the reconstructed image. We want to address this challenge by recovering individual crystals from ICS events with their corresponding energy deposits. This information could ultimately be fed into an image reconstruction framework. In this work, we established an algorithm based on a detector that couples a readout channel to each crystal (one-to-one coupling), which combines a measurement-driven calibration and a fitting routine to achieve the recovery of crystal interactions from measured light patterns. Using Geant4 simulations, we validated and optimized this approach by comparing the recovered events to the simulation ground truth. We showed that, with the best performing algorithm versions, all correct crystals could be identified for 95-97% of the simulated events and the crystal energies as well as the event energy sum could be recovered adequately. For the event energy sum a deviation of less than 5% could be achieved for 96% of all events. Overall, the developed ICS recovery algorithm was successfully validated for one-to-one coupled detector. Future application for other detector configurations should be possible and will be investigated. Additionally, using the new crystal interaction information to determine the most likely first interaction crystal is being examined to improve efficiency and signal-to-noise ratio in the PET reconstruction.

physics.med-ph

A Finely Segmented Semi-Monolithic Detector tailored for High Resolution PET

Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial systems often employ finely pixelated or monolithic scintillators, each with its limitations. We present a semi-monolithic detector, tailored for high-resolution PET applications, and merging concepts of monolithic and pixelated crystals. The detector features slabs measuring (24 x 10 x 1) sq. mm, coupled to a 12 x 12 readout channel photosensor with 4 mm pitch. The slabs are grouped in two arrays of 44 slabs each to achieve a higher optical photon density. We employ a fan beam collimator for fast calibration to train machine-learning-based positioning models for all three dimensions, including slab identification and depth-of-interaction (DOI), utilizing gradient tree boosting (GTB). Energy calculation was based on a position-dependent energy calibration. Using an analytical timing calibration, time skews were corrected for coincidence timing resolution (CTR) estimation. Leveraging machine-learning-based calibration in all three dimensions, we achieved high detector spatial resolution: down to 1.18 mm full width at half maximum (FWHM) detector spatial resolution and 0.75 mm mean absolute error (MAE) in the planar-monolithic direction along the slabs, and 2.14 mm FWHM and 1.03 mm MAE for depth-of-interaction (DOI) at an energy window of (435-585) keV. Correct slab interaction identification exceeded 80%, alongside an energy resolution of 13.8% and a CTR of 450 ps FWHM. Therewith, the introduced finely segmented, high-resolution slab detector demonstrates an appealing performance suitable for high-resolution PET applications. The current benchtop-based detector calibration routine allows these detectors to be used in PET systems.

physics.med-ph

Near-field coded-mask technique and its potential for proton therapy monitoring

Objective. Prompt-gamma imaging encompasses several approaches for online monitoring of beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via simulations. Approach. Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in a form of a MURA mask and a LYSO:Ce scintillation detector of fine granularity. The setups differed in the detector dimensions and the operation mode (1D or 2D imaging). A series of measurements with radioactive sources have been conducted, testing the setups' performance of near-field gamma imaging. Additionally, Monte Carlo simulations of a larger setup of the same type were conducted, investigating its performance with a realistic gamma source distribution occurring during proton therapy. Main results. The images of point-like sources reconstructed from two smallscale prototypes' data using the MLEM algorithm constitute the experimental proof of principle for the near-field coded-mask imaging modality, both in the 1D and the 2D mode. Their precision allowed us to calibrate out certain systematic offsets appearing due to the misalignment of setup elements. The simulation of the full-scale setup yielded a mean distal falloff retrieval precision of 0.72 mm in the studies for beam energy range 89.5-107.9 MeV and with 1x10^8 protons (typical number for single distal spots). The implemented algorithm of image reconstruction is relatively fast - a typical procedure needs several seconds. Significance. Coded-mask imaging appears a valid option for proton therapy monitoring. The results of simulations let us conclude that the proposed fullscale setup is competitive to the knife-edge-shaped and the multiparalell slit cameras investigated by other groups.

physics.med-ph

Improving the Timing Resolution of Positron Emission Tomography Detectors Using Boosted Learning -- A Residual Physics Approach

Artificial intelligence (AI) is entering medical imaging, mainly enhancing image reconstruction. Nevertheless, improvements throughout the entire processing, from signal detection to computation, potentially offer significant benefits. This work presents a novel and versatile approach to detector optimization using machine learning (ML) and residual physics. We apply the concept to positron emission tomography (PET), intending to improve the coincidence time resolution (CTR). PET visualizes metabolic processes in the body by detecting photons with scintillation detectors. Improved CTR performance offers the advantage of reducing radioactive dose exposure for patients. Modern PET detectors with sophisticated concepts and read-out topologies represent complex physical and electronic systems requiring dedicated calibration techniques. Traditional methods primarily depend on analytical formulations successfully describing the main detector characteristics. However, when accounting for higher-order effects, additional complexities arise matching theoretical models to experimental reality. Our work addresses this challenge by combining traditional calibration with AI and residual physics, presenting a highly promising approach. We present a residual physics-based strategy using gradient tree boosting and physics-guided data generation. The explainable AI framework SHapley Additive exPlanations (SHAP) was used to identify known physical effects with learned patterns. In addition, the models were tested against basic physical laws. We were able to improve the CTR significantly (more than 20%) for clinically relevant detectors of 19 mm height, reaching CTRs of 185 ps (450-550 keV).

cs.LG

Evaluation of semi-monolithic scintillators with integrated RF shielding material for a higher integration of PET/MRI systems

The integration of PET into MRI to form a hybrid system requires often compromises for both subsystems. For example, the integration might come at the cost of a reduced PET detector height or a reduced MRI examination volume diameter. Here, we propose a so-called shared-volume concept to use the volume required for both subsystems more efficiently, in which the MR transparency of the scintillator is exploited by integrating the RF shielding into the scintillator of the PET detector. Semi-monolithic scintillator prototypes (PVC slabs) of 7 mm and 12 mm height with integrated copper foil between every and every other slab, respectively, were investigated to evaluate the shielding effectiveness (SE). The SE was measured with probes on a test bench system. In addition, the PET detector performance was evaluated by determining the positioning using gradient tree boosting, energy and timing resolution using digital SiPM arrays (DPC3200, PDPC) in three LYSO scintillator configurations: ESR separation (Slab$\mathrm{_{ESR}}$), ESR with copper foil in between (Slab$\mathrm{_{ESR+Cu}}$), and purely copper foil separation (Slab$\mathrm{_{Cu}}$). The prototype with shielding between each slab and 12 mm height showed the highest SE with 31 dB (mean) in combination with a supporting frame. While Slab$\mathrm{_{Cu}}$ was best for positioning, followed by Slab$\mathrm{_{ESR}}$ and Slab$\mathrm{_{ESR+Cu}}$, the Slab$\mathrm{_{ESR}}$ had the best energy resolution (10.6 %), followed by Slab$\mathrm{_{ESR+Cu}}$ (11.2 %) and Slab$\mathrm{_{Cu}}$ (12.6 %). For the timing resolution, Slab$\mathrm{_{ESR}}$ and Slab$\mathrm{_{Cu}}$ achieved 279 ps and 288 ps, respectively. Slab$\mathrm{_{ESR+Cu}}$ performed worst (293 ps). The scintillator-based RF shielding shows good RF shielding with similar PET performance, demonstrating the potential for more effective integration of PET detectors into MRI systems.

physics.ins-det

A Semi-Monolithic Detector providing intrinsic DOI-encoding and sub-200 ps CRT TOF-Capabilities for Clinical PET Applications

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes radial astigmatism as the DOI remains unknown. We propose an alternative, aiming to combine the advantages of current detectors with the DOI capabilities shown for monolithic concepts, based on semi-monolithic scintillators (slabs). An array of 8 monolithic LYSO slabs of dimensions 3.9 x 32 x 19 mm3 was read out by a 64-channel photosensor containing digital SiPMs. The position estimation in the detector's monolithic and DOI direction was based on a calibration with a fan beam collimator and the machine learning technique gradient tree boosting (GTB). We achieved a positioning performance in terms of mean absolute error (MAE) of 1.44 mm and 2.12 mm for DOI considering a wide energy window of 300 - 700 keV. The energy resolution was determined to be 11.3%. We established both an analytical and machine-learning-based timing calibration approach and applied them for a first-photon trigger. The analytical timing calibration corrects for electronic and optical time skews leading to 240 ps coincidence resolving time (CRT) for a pair of slab-detectors. The CRT was significantly improved by utilizing GTB to predict the time difference based on specific training data and applied on top of the analytical calibration. We achieved 209 ps for the wide energy window and 198 ps for a narrow selection around the photopeak (411 - 561 keV). To maintain the detector's sensitivity, no filters were applied to the data during processing. Overall, the semi-monolithic detector provides attractive performance characteristics. Especially, a good CRT can be achieved while introducing DOI capabilities to the detector, making the concept suitable for clinical PET scanners.

physics.ins-det

Evaluation Of The PETsys TOFPET2 ASIC In Multi-Channel Coincidence Experiments

Aiming to measure the difference in arrival times of two coincident gamma-photons with an accuracy in the order of 200 ps, time-of-flight positron emission tomography systems commonly employ silicon photomultipliers (SiPMs) and high-resolution digitization electronics, application specific integrated circuits (ASICs). This work evaluates the performance of the TOFPET2 ASIC, released by PETsys Electronics S.A. in 2017, dependent on its configuration parameters in multi-channel coincidence measurements. SiPM arrays fabricated by different vendors (KETEK, SensL, Hamamatsu, Broadcom) were tested in combination with the ASIC. Scintillator arrays featuring different reflector designs and different configurations of the TOFPET2 ASIC software parameters were evaluated. The benchtop setup used is provided with the TOFPET2 ASIC evaluation kit by PETsys Electronics S.A.. Compared to existing studies featuring the TOFPET2 ASIC, multi-channel performance results dependent on a larger set of ASIC configuration parameters were obtained that have not been reported to this extend so far. The ASIC shows promising CRTs down to 219.9 ps in combination with two Hamamatsu S14161-3050-HS-08 SiPM arrays (128 channels read out, energy resolution 13.08 %) and 216.1 ps in combination with two Broadcom AFBR-S4N44P643S SiPM arrays (32 channels read out, energy resolution 9.46 %). The length of the trigger delay of the dark count suppression scheme has an impact on the ASIC performance. The integrator gain configuration has been investigated and allows an improvement of the energy resolution. Measuring up to the time-of-flight performance of state-of-the-art positron emission tomography (ToF-PET) systems while providing a uniform and stable readout for multiple channels at the same time, the TOFPET2 ASIC is treated as promising candidate for the integration in future ToF-PET systems.

physics.med-ph

Investigation of the Power Consumption of the PETsys TOFPET2 ASIC

In state-of-the-art positron emission (PET) tomography systems, application-specific integrated circuits (ASICs)are commonly used to precisely digitize the signals of analog silicon photo-multipliers (SiPMs). However, when operating PET electronics in a magnetic resonance (MR) system, one faces the challenge of mutual interference of these imaging techniques. To prevent signal deterioration along long analog signal lines, PET electronics with a low power consumption digitizing the signals close to the SiPMs are preferred. In this study, we evaluate the power consumption of the TOFPET2 ASIC. Its power consumption ranges from 3.6 to 7.2 mW/channel as a function of the input stage impedance and discriminator noise settings. We present an analytical model allowing to compute the power consumption of a given ASIC configuration. The configured input stage impedance and discriminator noise have an impact on the coincidence resolution time, energy resolution, and photon trigger level. Since the TOFPET2 ASIC delivers state-of-the-art performance with a power consumption similar or even lower than other ASICs typically used for PET applications, it is a favorable candidate to digitize the signals of SiPMs in future simultaneous PET/MR systems.

physics.ins-det

Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs

The National Electrical Manufacturers Association's (NEMA) NU 4-2008 standard specifies methodology for evaluating the performance of small-animal PET scanners. The standard's goal is to enable comparison of different PET scanners over a wide range of technologies and geometries used. In this work, we discuss if the NEMA standard meets these goals and we point out potential flaws and improvements to the standard. For the evaluation of spatial resolution, the NEMA standard mandates the use of filtered backprojection reconstruction. This reconstruction method can introduce star-like artifacts for detectors with an anisotropic spatial resolution, usually caused by parallax error. These artifacts can then cause a strong dependence of the resulting spatial resolution on the size of the projection window in image space, whose size is not fully specified in the NEMA standard. We show that the standard's equations for the estimation of the random rate for PET systems with intrinsic radioactivity are circular and not satisfiable. We compare random rates determined by a method based on the standard to to random rates obtained using a delayed coincidence window and two methods based on the singles rates. We discuss to what extend the NEMA standard's protocol for the evaluation of the sensitivity is unclear and ambiguous, which can lead to unclear interpretations of publicizeded results. The standard's definition of the recovery coefficients in the image quality phantom includes the maximum activity in a region of interest, which causes a positive correlation of noise and recovery coefficients. This leads to an unintended trade-off between desired uniformity, which is negatively correlated with variance (i.e. noise), and recovery. With this work, we want to start a discussion on possible improvements in a next version of the NEMA NU-4 standard.

physics.med-ph

A novel DOI Positioning Algorithm for Monolithic Scintillator Crystals in PET based on Gradient Tree Boosting

Monolithic crystals are examined as an alternative to segmented scintillator arrays in positron emission tomography (PET). Monoliths provide good energy, timing and spatial resolution including intrinsic depth of interaction (DOI) encoding. DOI allows reducing parallax errors (radial astigmatism) at off-center positions within a PET ring. We present a novel DOI-estimation approach based on the supervised machine learning algorithm gradient tree boosting (GTB). GTB builds predictive regression models based on sequential binary comparisons (decision trees). GTB models have been shown to be implementable in FPGA if the memory requirement fits the available resources. We propose two optimization scenarios for the best possible positioning performance: One restricting the available memory to enable a future FPGA implementation and one without any restrictions. The positioning performance of the GTB models is compared with a DOI estimation method based on a single DOI observable (SO) comparable to other methods presented in literature. For a 12 mm high monolith, we achieve an averaged spatial resolution of 2.15 mm and 2.12 mm FWHM for SO and GTB models, respectively. In contrast to SO models, GTB models show a nearly uniform positioning performance over the whole crystal depth.

physics.med-ph

Initial Measurements with the PETsys TOFPET2 ASIC Evaluation Kit and a Characterization of the ASIC TDC

For a first characterization, we used the two KETEK-PM3325-WB SiPMs each equipped with a 3x3x5 mm${}^3$ LYSO scintillation crystal provided with the PETsys TOFPET2 ASIC Evaluation Kit. We changed the lower of two discriminator thresholds (D_T1) in the timing branch from vth_t1 = 5 - 30. The overvoltage was varied in a range of 1.25 V - 7.25 V. The ambient temperature was kept at 16°C. For all measurements, we performed an energy calibration including a correction for saturation. We evaluated the energy resolution, the coincidence resolving time (CRT) and the coincidence rate. At an overvoltage of 6 V, we obtained an energy resolution of about 10% FWHM, a CRT of approximately 210 ps FWHM and 400 ps FWTM, the coincidence rate showed only small variations of about 5%. To investigate the influence of the ambient temperature, it was varied between 12°C - 20°C. At 12°C and an overvoltage of 6.5 V, a CRT of approx. 195 ps FWHM and an energy resolution of about 9.5% FWHM could be measured. Observed satellite peaks in the time difference spectra were investigated in more detail. We could show that the location of the satellite peaks is correlated with a programmable delay element in the trigger circuit.

physics.ins-det

Initial PET Performance Evaluation of a Preclinical Insert for PET/MRI with Digital SiPM Technology

Hyperion-IID is a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. To read out the scintillation light of the employed LYSO crystal arrays with a pitch of 1 mm pitch and 12 mm in height, digital silicon photomultipliers (DPC 3200-22, Philips Digital Photon Counting) (DPC) are used. The basic PET performance in terms of energy resolution, coincidence resolution time (CRT) and sensitivity as a function of operating parameters, such as the operating temperature, the applied overvoltage, activity and configuration parameters of the DPCs, were evaluated on system level. The measured energy resolution did not show a large dependency on the selected parameters and is in the range of 12.4-12.9% for low activities and degrades to ~13.6% at activities of ~100 MBq. The CRT strongly depends on the selected trigger scheme (trig) of the DPCs. We measured approximately 260 ps, 440 ps, 540 ps and 1300 ps for trig 1-4, respectively. The trues sensitivity for a NEMA NU 4 mouse-sized scatter phantom with a 70-mm-long tube of activity was dependent on the operating parameters and was determined to be 0.4-1.4% at low activities. The random fraction stayed below 5% at activities up to 100 MBq and the scatter fraction was evaluated as ~6% for an energy window of 411-561 keV and ~16% for 250-625 keV. Furthermore, we performed imaging experiments using a mouse-sized hot-rod phantom and a large rabbit-sized phantom. In 2D slices of the reconstructed mouse-sized hot-rod phantom (Ø = 28 mm), the rods were distinguishable from each other down to a rod size of 0.8 mm. There was no benefit of the better CRT of trig 1 over trig 3, where in the larger rabbit-sized phantom (Ø = 114 mm), we could show a clear improvement of image quality using the time-of-flight information.

physics.ins-det