Searcharxiv⌕ Search

arXiv subjects

Dawn Boynton

Publications and source records attributed to Dawn Boynton.

2 recordsLinked to original sources

Three-Dimensional Ultrasound Localization Microscopy Using Hadamard-Encoded Multipulse and 4D Denoising on a 256-Channel System with a 1024-element Matrix Array: A Feasibility Study in Human Kidney Transplants

Three-dimensional ultrasound localization microscopy (3D ULM) enables volumetric visualization of microvasculature beyond the acoustic diffraction limit, but its clinical translation remains limited by long acquisition times, low microbubble (MB) signal-to-noise ratio (SNR), and insufficient MB contrast, particularly on ultrasound systems with a limited number of acquisition channels. In this study, we developed an in-human 3D ULM framework for a 256-channel research ultrasound system equipped with a 1024-element matrix array. The framework combines diverging-wave Hadamard-encoded multipulse (HEM) transmission to enhance MB SNR with denoising strategy combining MB enhancement and four-dimensional non-local means filtering to improve MB contrast. The framework was implemented on a research ultrasound platform and evaluated in phantom experiments and four in vivo human kidney transplants. In phantom experiments, HEM improved the MB contrast ratio around 2 dB, while the proposed denoising strategy enhanced in vivo MB contrast by up to around 9 dB. 3D ULM reconstruction achieved a spatial resolution of approximately 84 um, as estimated by Fourier shell correlation. The number of reconstructed microvascular voxels increased exponentially with acquisition duration, reaching approximately 74% of the estimated saturated vessel density using 3000 volumes (~12 s). The subject with the highest histopathological injury exhibited quantitatively reduced microvascular vessel density, flow velocities, and mean perfusion index. These results demonstrate that the proposed framework enables high-quality volumetric super-resolution imaging and quantitative characterization of renal microvasculature using a 256-channel ultrasound system, providing a practical step toward the clinical translation of in vivo 3D ULM.

physics.med-ph↗

Reducing Spectral Oscillations for Robust Reference Frequency-Based Ultrasound Attenuation Estimation in Harmonic Imaging

Ultrasound attenuation coefficient estimation (ACE) has emerged as a quantitative imaging biomarker for noninvasive assessment of hepatic steatosis. A system-independent technique based on spectral normalization, known as the reference frequency method (RFM), was previously proposed to estimate ACE without requiring a well-calibrated reference phantom. Furthermore, incorporating harmonic imaging can significantly suppress reverberation signals. In previous clinical study, RFM has achieved high correlation with MRI-PDFF, demonstrating its potential for clinical application. However, a major challenge of RFM is the presence of oscillations in the frequency power-ratio decay curves (FPDCs), which can distort the linear fitting used to estimate the attenuation coefficient and consequently degrade ACE accuracy. These oscillations arise from constructive and destructive interference among backscattered echoes, resulting in oscillatory fluctuations in the measured power spectrum that propagate into the FPDCs. We propose a transmission scheme combining multiple frequencies and steering angles to mitigate oscillations in the FPDCs. Averaging these FPDCs suppresses the interference-induced oscillations while preserving the attenuation-dependent decay trend, thereby improving linearity and the accuracy of ACE results. In in-vitro experiments using calibrated phantoms (0.5 and 0.76 dB/cm/MHz) demonstrated that the proposed method improved FPDC linearity and ACE accuracy, achieving an R2 of 0.99 and attenuation coefficient estimates of 0.51 and 0.77 dB/cm/MHz, versus an R2 of 0.89 and estimates of 0.56 and 0.70 dB/cm/MHz for conventional RFM. The proposed method also demonstrated superior performance in a pilot patient study (n=15), achieving a stronger correlation with MRI-PDFF (R = 0.89 vs. 0.83) while reducing inter-measurement variability, indicating improved robustness and clinical potential.

physics.med-ph↗