SearcharxivSearch

arXiv subjects

Dean Forshaw

Publications and source records attributed to Dean Forshaw.

4 recordsLinked to original sources

DsTau: Study of tau neutrino production with 400 GeV protons from the CERN-SPS

In the DsTau experiment at the CERN SPS, an independent and direct way to measure tau neutrino production following high energy proton interactions was proposed. As the main source of tau neutrinos is a decay of Ds mesons, produced in proton-nucleus interactions, the project aims at measuring a differential cross section of this reaction. The experimental method is based on a use of high resolution emulsion detectors for effective registration of events with short lived particle decays. Here we present the motivation of the study, details of the experimental technique, and the first results of the analysis of the data collected during test runs, which prove feasibility of the full scale study of the process in future.

hep-ex

Module concept and thermo-mechanical studies of the silicon-based TT-PET small-animal scanner

The TT-PET collaboration is developing an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of alternating layers of high-Z photon converter and 100 $\mathrm{μm}$ silicon sensors, to produce a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2 $\mathrm{mm^{3}}$ granularity for precise depth-of-interaction measurement. In this paper we present the results of simulation studies for the expected data rate, time-of-flight and spatial resolution, as well as the performance of image reconstruction with and without the use of timing information.

physics.ins-det

Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project

The TT-PET collaboration is developing a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage of 180 V. The tests on a beam line of minimum ionizing particles show a detection efficiency greater than 99.9 % and a time resolution down to 110 ps.

physics.ins-det

Charge collection characterisation with the Transient Current Technique of the ams H35DEMO CMOS detector after proton irradiation

This paper reports on the characterisation with Transient Current Technique measurements of the charge collection and depletion depth of a radiation-hard high-voltage CMOS pixel sensor produced at ams AG. Several substrate resistivities were tested before and after proton irradiation with two different sources: the 24 GeV Proton Synchrotron at CERN and the 16.7 MeV Cyclotron at Bern Inselspital.

physics.ins-det