SearcharxivSearch

arXiv subjects

Debraj Bhattacharjee

Publications and source records attributed to Debraj Bhattacharjee.

4 recordsLinked to original sources

Spatial Characterization of Sub-Synchronous Oscillations Using Black-Box IBR Models

Power systems with high penetration of inverter-based resources (IBRs) are prone to sub-synchronous oscillations (SSO). The opaqueness of vendor-specific IBR models limits the ability to predict the severity and the spread of SSO. This paper demonstrates that black-box IBR models estimated through frequency-domain identification techniques, along with dynamic network model can replicate the actual oscillatory behavior. The estimated IBR models are validated against actual IBR models in a closed-loop multi-IBR test system through modal analysis by comparing closed-loop eigenvalues, and participation factors. Furthermore, using output-observable right eigenvectors, spatial heatmaps are developed to visualize the spread and severity of dominant SSO modes. The case studies on the 11-bus and 39-bus test systems confirm that even with the estimated IBR models, the regions susceptible to SSO can be identified in IBR-dominated power systems.

eess.SY

Data-Driven Post-Event Analysis with Real-World Oscillation Data from Denmark

This paper demonstrates how Extended Dynamic Mode Decomposition (EDMD), grounded in Koopman operator theory, can effectively identify the main contributor(s) to oscillations in power grids. We use PMU data recorded from a real 0.15 Hz oscillation event in Denmark for post-event analysis. To this end, the EDMD algorithm processed only voltage and current phasors from nineteen PMUs at different voltage levels across the Danish grid. In such a blind-test setting with no supplementary system information, EDMD accurately pinpointed the location of the main contributor to the 0.2 Hz oscillation, consistent with the location of the problematic IBR plant later confirmed by Energinet, where the underlying cause was a control system issue. Conventional approaches, such as the dissipating energy flow (DEF) method used in the ISO-NE OSL tool did not clearly identify this plant. This joint validation with Energinet, reinforcing earlier studies using simulated IBR-dominated systems and real PMU data from ISO-NE, highlights the potential of EDMD-based post-event analysis for identifying major oscillation contributors and enabling targeted SSO mitigation.

eess.SY

A Data-Driven Method to Identify Major Contributors to Low-Frequency Oscillations

We present a purely data-driven method to pinpoint generation plants that significantly contribute to poorly damped oscillations as part of post-event analysis. First, Extended Dynamic Mode Decomposition (EDMD) is applied on PMU data from the point of interconnection (POI) of the plants to obtain the finite-dimensional Koopman operator. Then, modal analysis is performed on a reduced-order Koopman operator to extract spatio-temporal patterns. The data-driven eigenvalues and eigenvectors quantify each plant's contribution to critical oscillatory modes without requiring any system model information. We demonstrate the effectiveness of this method through simulated case studies on modified IEEE 39-bus and WECC 179-bus test systems by benchmarking the data-driven results against ground-truth models. Its performance is further validated using PMU data from real oscillation events in the ISO-New England system. This data-driven method offers a practical tool for both planning-stage simulations and post-event analysis of real oscillation events, enabling effective mitigation.

eess.SY

Data-Driven Selection of Actuators for Optimal Control of Airfoil Separation

We present a systematic approach for determining the optimal actuator location for separation control from input-output response data, gathered from numerical simulations or physical experiments. The Eigensystem Realization Algorithm is used to extract state-space descriptions from the response data associated with a candidate set of actuator locations. These system realizations are then used to determine the actuator location among the set that can drive the system output to an arbitrary value with minimal control effort. The solution of the corresponding minimum energy optimal control problem is evaluated by computing the generalized output controllability Gramian. We use the method to analyze high-fidelity numerical simulation data of the lift and separation-angle responses to a pulse of localized body-force actuation from six distinct locations on the upper surface of a NACA 65(1)-412 airfoil. We find that the optimal location for controlling lift is different from the optimal location for controlling separation angle. In order to explain the physical mechanisms underlying these differences, we conduct controllability analyses of the flowfield by leveraging the dynamic mode decomposition with control algorithm. These modal analyses of flowfield response data reveal that excitation of coherent structures in the wake benefit lift control; whereas, excitation of coherent structures in the shear layer benefit separation-angle control.

physics.flu-dyn