SearcharxivSearch

arXiv subjects

Declan O'Neill

Publications and source records attributed to Declan O'Neill.

6 recordsLinked to original sources

Fast, low noise, megapixel detector and readout systems for future X-ray astronomy missions

Next-generation strategic X-ray astronomy missions will require the simultaneous achievement of high angular resolution, large effective collecting area, and wide-field imaging with large-format focal plane detectors. Realizing the associated science objectives--ranging from precision measurements of bright point sources to the detection and characterization of faint diffuse emission-places stringent and, in some cases, competing requirements on detector performance. In particular, high frame rates are necessary to mitigate photon pile-up in observations of bright sources and to reduce contamination from particle-induced background in measurements of low surface brightness structures. At the same time, these instruments must preserve excellent soft X-ray response, which places tight constraints on read noise and on the fidelity of event characterization. State-of-the-art X-ray charge-coupled devices (CCDs) approach many of the key performance metrics required for these missions, but readout speed remains a primary limitation. Addressing this gap requires readout architectures that scale to high channel count, sustain high pixel throughput, and preserve the low-noise characteristics needed for soft X-ray sensitivity.

astro-ph.IM

High-speed, low-noise, multi-megapixel CCDs for next generation X-ray observatories

Next generation X-ray observatories require fast, low-noise, low-power, multi-megapixel imaging spectrometers. To meet these demands, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in partnership with the MIT Kavli Institute and MIT Lincoln Laboratory (MIT-LL), is developing multi-channel X-ray charge-coupled devices (CCDs) and fast readout architectures. We report the energy resolution and noise performance achieved with a full-scale (1440x1440-pixel), 16-channel, front-illuminated MIT-LL CCD detector developed for the Advanced X-ray Imaging Satellite (AXIS) concept, the CCID-100, read out using two Multi-Channel Readout Chip (MCRC) V1 application-specific integrated circuit (ASIC) chips in the new Stanford CCID-100 test setup. We describe an automated method for bias optimization on each CCD channel, and integrated debugging features of the front-end ASIC and readout system. The demonstrated performance confirms that these systems can meet the speed and noise requirements of future strategic X-ray missions.

astro-ph.IM

Advancing X-Ray Camera Front-End Electronics Architecture through the AXIS-TAP Technology Platform

Advancing time-domain soft X-ray astronomy demands focal plane readout electronics capable of high-speed digitization with low noise while maintaining spectral fidelity across multiple detector channels. The Advanced X-ray Imaging Satellite (AXIS), a NASA Probe-class mission concept, provided the driving requirements and heritage for developing a generalized high-speed (>=5 fps) camera Front-End Electronics (FEE) architecture applicable to future soft X-ray missions. The FEE architecture defines a modular, dual-box redundant configuration to operate a focal plane of four 16-channel CCDs, with functional partitioning for power distribution, thermal management, mechanism control, and image data acquisition and transmission to the spacecraft. To validate the core signal chain architecture, particularly the analog-to-digital conversion, FPGA-based processing, and Ethernet data transmission, a dedicated technology demonstrator, AXIS-TAP (ADC Testing and Acquisition Platform), has been designed and is currently in fabrication. AXIS-TAP employs commercial equivalents of radiation-tolerant components (FPGA, ADCs, Ethernet PHY) and interfaces directly with the STA Archon benchtop readout system, enabling simultaneous image acquisition from both systems to validate that the flight-like architecture achieves equivalent or superior noise performance. This paper presents the FEE architectural framework, the AXIS-TAP demonstrator design, and the design principles that enable scalability to future soft X-ray missions with similar detector requirements. Performance validation results will be reported upon completion of AXIS-TAP system integration and testing.

astro-ph.IM

The High-Speed FPGA Readout System for the Advanced X-ray Imaging Satellite (AXIS)

The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class mission concept designed to deliver arcsecond spatial resolution, high-sensitivity spectral imaging across the 0.3-10 keV band. The X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing the AXIS X-ray camera, including both the detector and the front-end readout electronics required to meet the mission's demanding performance goals. The telescope's focal plane detector consists of four 1440x1440 pixel charge-coupled devices (CCDs) developed by MIT-LL, each featuring 16 parallel output channels. These outputs are amplified by a high-speed, low-power, low-noise application-specific integrated circuit (ASIC) - the Multi-Channel Readout Chip (MCRC) - developed at Stanford. Following amplification, the analog signals are digitized and processed to construct a pixel array, prior to event detection. Here, we present the field-programmable gate array (FPGA) architecture developed to enable high-speed, parallelized readout of these CCD channels. The FPGA samples 16 analog-to-digital converter (ADC) channels at 50 MHz, performs preprocessing of pixel data, which is then streamed via User Datagram Protocol (UDP) over a 1 Gb Ethernet link to the back-end system for event reconstruction. Our design demonstrates the goal readout performance for AXIS (20 frames per second) and provides a framework for future high-throughput X-ray observatories.

astro-ph.IM

RNDR noise modeling in first-generation Single electron Sensitive Readout (SiSeRO) devices

Flagship observatories require single-photon detectors with ultra-fast readout, sub-electron noise performance, and scalable large-format architectures. The X-ray Astronomy and Observational Cosmology group at Stanford, in collaboration with the MIT Kavli Institute and MIT Lincoln Laboratory, is developing readout technologies for next-generation detectors. Prototypes employing Single-electron Sensitive Readout (SiSeRO) amplifiers demonstrate excellent read noise and spectral performance using repetitive non-destructive readout (RNDR), achieving 0.5 e$^-$ noise in under 57 cycles. We have modeled noise for longer RNDR cycles, exploring probabilistic mechanisms such as thermal leakage and impact ionization. Here we present our model results, including statistical limits on dark current-like signals. Maturation of SiSeRO technology will improve detector performance at soft X-ray energies, addressing technology gaps for future X-ray and UV/visible/near-IR observatories.

astro-ph.IM

First results for second generation SiSeRO CCD devices

The Astro2020 Decadal recommended the development of a suite of next generation astronomical observatories spanning the X-ray to near-IR spectrum. These programs require fast, extremely low noise detectors to fulfill their science goals. To address this technology gap, Stanford X-ray Astronomy and Observational Cosmology (XOC) group, MIT Lincoln Laboratory (MIT-LL), and MIT Kavli Institute (MKI) are advancing Single electron Sensitive Read Out (SiSeRO), a multiband detector technology capable of achieving substantially sub-electron noise via Repetitive Non-Destructive Readout (RNDR). We present initial results for our second generation SiSeRO CCDs. We also discuss our test bed, including a readout electronics system capable of accommodating all second-generation SiSeRO CCD variants utilizing the XOC-designed Multi-Channel Readout Chip (MCRC) ASIC.

astro-ph.IM