SearcharxivSearch

arXiv subjects

Dehua Yang

Publications and source records attributed to Dehua Yang.

4 recordsLinked to original sources

Research on fine co-focus adjustment method for segmented solar telescope

For segmented telescopes, achieving fine co-focus adjustment is essential for realizing co-phase adjustment and maintenance, which involves adjusting the millimeter-scale piston between segments to fall within the capture range of the co-phase detection system. CGST proposes using a SHWFS for piston detection during the co-focus adjustment stage. However, the residual piston after adjustment exceeds the capture range of the broadband PSF phasing algorithm$(\pm 30 μm) $, and the multi-wavelength PSF algorithm requires even higher precision in co-focus adjustment. To improve the co-focus adjustment accuracy of CGST, a fine co-focus adjustment based on cross-calibration is proposed. This method utilizes a high-precision detector to calibrate and fit the measurements from the SHWFS, thereby reducing the impact of atmospheric turbulence and systematic errors on piston measurement accuracy during co-focus adjustment. Simulation results using CGST demonstrate that the proposed method significantly enhances adjustment accuracy compared to the SHWFS detection method. Additionally, the residual piston after fine co-focus adjustment using this method falls within the capture range of the multi-wavelength PSF algorithm. To verify the feasibility of this method, experiments were conducted on an 800mm ring segmented mirror system, successfully achieving fine co-focus adjustment where the remaining piston of all segments fell within $\pm 15 μm$.

astro-ph.IM

The Jiao Tong University Spectroscopic Telescope Project

The Jiao Tong University Spectroscopic Telescope (JUST) is a 4.4-meter f/6.0 segmentedmirror telescope dedicated to spectroscopic observations. The JUST primary mirror is composed of 18 hexagonal segments, each with a diameter of 1.1 m. JUST provides two Nasmyth platforms for placing science instruments. One Nasmyth focus fits a field of view of 10 arcmin and the other has an extended field of view of 1.2 deg with correction optics. A tertiary mirror is used to switch between the two Nasmyth foci. JUST will be installed at a site at Lenghu in Qinghai Province, China, and will conduct spectroscopic observations with three types of instruments to explore the dark universe, trace the dynamic universe, and search for exoplanets: (1) a multi-fiber (2000 fibers) medium-resolution spectrometer (R=4000-5000) to spectroscopically map galaxies and large-scale structure; (2) an integral field unit (IFU) array of 500 optical fibers and/or a long-slit spectrograph dedicated to fast follow-ups of transient sources for multimessenger astronomy; (3) a high-resolution spectrometer (R~100000) designed to identify Jupiter analogs and Earth-like planets, with the capability to characterize the atmospheres of hot exoplanets.

astro-ph.IM

Advancing COVID-19 Diagnosis with Privacy-Preserving Collaboration in Artificial Intelligence

Artificial intelligence (AI) provides a promising substitution for streamlining COVID-19 diagnoses. However, concerns surrounding security and trustworthiness impede the collection of large-scale representative medical data, posing a considerable challenge for training a well-generalised model in clinical practices. To address this, we launch the Unified CT-COVID AI Diagnostic Initiative (UCADI), where the AI model can be distributedly trained and independently executed at each host institution under a federated learning framework (FL) without data sharing. Here we show that our FL model outperformed all the local models by a large yield (test sensitivity /specificity in China: 0.973/0.951, in the UK: 0.730/0.942), achieving comparable performance with a panel of professional radiologists. We further evaluated the model on the hold-out (collected from another two hospitals leaving out the FL) and heterogeneous (acquired with contrast materials) data, provided visual explanations for decisions made by the model, and analysed the trade-offs between the model performance and the communication costs in the federated training process. Our study is based on 9,573 chest computed tomography scans (CTs) from 3,336 patients collected from 23 hospitals located in China and the UK. Collectively, our work advanced the prospects of utilising federated learning for privacy-preserving AI in digital health.

cs.AI

Research of the active reflector antenna using laser angle metrology system

Active reflector is one of the key technologies for constructing large telescopes, especially for the millimeter/sub-millimeter radio telescopes. This article introduces a new efficient laser angle metrology system for the active reflector antenna of the large radio telescopes, with a plenty of active reflector experiments mainly about the detecting precisions and the maintaining of the surface shape in real time, on the 65-meter radio telescope prototype constructed by Nanjing Institute of Astronomical Optics and Technology (NIAOT). The test results indicate that the accuracy of the surface shape segmenting and maintaining is up to micron dimension, and the time-response can be of the order of minutes. Therefore, it is proved to be workable for the sub-millimeter radio telescopes.

astro-ph.IM