Tabular foundation models for robust calibration of near-infrared chemical sensing data

Near-infrared spectroscopy is increasingly used as a rapid, non-destructive chemical sensing technology for the analysis of food, pharmaceutical, biological, and environmental samples. However, the practical deployment of NIR sensors still depends on calibration models able to handle high-dimensional, collinear spectra, limited sample sizes, preprocessing dependence, spectral outliers, and extrapolation beyond the calibration domain. Here, we evaluate whether tabular foundation models can provide a new calibration strategy for NIR chemical sensing. We benchmark TabPFN on 66 NIR datasets covering 54 regression and 12 classification tasks, and compare direct inference on raw spectra with preprocessing-optimized inference against PLS/PLS-DA, Ridge, Catboost, and one-dimensional convolutional neural networks. The study uses a unified validation framework in which preprocessing and model selection are performed exclusively on calibration data before external test evaluation. In regression, preprocessing-optimized TabPFN achieves the best overall average rank and significantly outperforms PLS, CatBoost, TabPFN on raw spectra, and CNN-1D, while remaining statistically comparable to Ridge. In classification, TabPFN applied directly to raw spectra provides the best average rank, with performance close to the optimized variant. Robustness analyses show that TabPFN provides strong average predictive performance but that its advantage decreases on spectral outliers and extrapolated samples, where classical chemometric models remain competitive. These results suggest that tabular foundation models can complement established chemometric workflows for NIR chemical sensing, especially in small- to medium-sized calibration settings, while highlighting the need for spectroscopy-specific priors and uncertainty-aware deployment strategies.

cs.LG

Reframing preprocessing selection as model-internal calibration in near-infrared spectroscopy: A large-scale benchmark of operator-adaptive PLS and Ridge models

Preprocessing screening is often the most expensive part of a near-infrared spectroscopy calibration workflow. It works because smoothing, derivatives, detrending and related filters change the spectral directions seen by partial least squares (PLS) or Ridge regression, but a full external search repeatedly refits nearly the same linear model. This paper studies the case where that search can be collapsed into one calibration step. For a strict linear preprocessing operator A acting on row spectra as XA^T, the transformed PLS cross-covariance satisfies (XA^T)^T Y = A X^T Y, and Ridge regression depends on the operator-induced kernel X A^T A X^T. These identities let a finite operator bank be screened inside the model while retaining original-wavelength coefficients, and the same identity extends to cheaply evaluated linear operator chains. Sample-adaptive or fitted corrections such as SNV, MSC, EMSC and ASLS are not strict linear; we prove the boundary and keep them as fold-local branches. The cohort has 61 regression and 17 classification rows, with a strict paired regression denominator of N=32 for the eight paper variants. There, AOM-PLS reaches median RMSEP ratios of 0.991/0.990 (simple) and 0.985/1.002 (best) against PLS-default/PLS-HPO, and AOM-Ridge reaches 0.974/0.984 (simple) and 0.918/0.966 (best) against Ridge-default/Ridge-HPO. The operator-adaptive classifier AOM-PLS-DA improves balanced accuracy by a median 0.159 on N=13 datasets (12/13 wins). The practical result is the runtime gap: PLS-HPO takes a median 710.81 s per run, whereas AOM-PLS takes 1.18-1.63 s -- 436 to 602 times less PLS fitting time. Linear operator-adaptive calibration thus gives prediction quality comparable to exhaustive preprocessing screening, with orders-of-magnitude less fitting time for PLS.

stat.ML