SearcharxivSearch

arXiv subjects

Denis Dolzhenko

Publications and source records attributed to Denis Dolzhenko.

3 recordsLinked to original sources

Towards Quantum Telescopes: Demonstration of a Two-Photon Interferometer for Quantum-Assisted Astronomy

Classical optical interferometery requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations, and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.

astro-ph.IM

Intensified Tpx3Cam, a fast data-driven optical camera with nanosecond timing resolution for single photon detection in quantum applications

We describe a fast data-driven optical camera, Tpx3Cam, with nanosecond scale timing resolution and 80 Mpixel/sec throughput. After the addition of intensifier, the camera is single photon sensitive with quantum efficiency determined primarily by the intensifier photocathode. The single photon performance of the camera was characterized with results on the gain, timing resolution and afterpulsing reported here. The intensified camera was successfully used for measurements in a variety of applications including quantum applications. As an example of such application, which requires simultaneous detection of multiple photons, we describe registration of photon pairs from the spontaneous parametric down-conversion source in a spectrometer. We measured the photon wavelength and timing with respective precisions of 0.15~nm and 3~ns, and also demonstrated that the two photons are anti-correlated in energy.

physics.ins-det

Quantum-Assisted Optical Interferometers: Instrument Requirements

It has been recently suggested that optical interferometers may not require a phase-stable optical link between the stations if instead sources of quantum-mechanically entangled pairs could be provided to them, enabling extra-long baselines and benefiting numerous topics in astrophysics and cosmology. We developed a new variation of this idea, proposing that photons from two different sources could be interfered at two decoupled stations, requiring only a slow classical connection between them. We show that this approach could allow high-precision measurements of the relative astrometry of the two sources, with a simple estimate giving angular resolution of $10 \ \mu$as in a few hours' observation of two bright stars. We also give requirements on the instrument for these observations, in particular on its temporal and spectral resolution. Finally, we discuss possible technologies for the instrument implementation and first proof-of-principle experiments.

astro-ph.IM