SearcharxivSearch

arXiv subjects

Denis Martynov

Publications and source records attributed to Denis Martynov.

At least 19 recordsLinked to original sources

Torsional-X Seismometer for Lunar Decihertz Gravitational-Wave Detection

The lunar gravitational-wave antenna concept uses the Moon as a resonant detector instrumented with precision seismometers, targeting the decihertz band between ground- and space-based observatories. We propose a compact monolithic fused-silica torsional-X seismometer that re-engineers garden-gate acceleration-to-rotation transduction for this regime through a high-tension dual-fiber suspension. Its designed millihertz-scale resonance and ultra-low mechanical dissipation enable a nearly order-of-magnitude improvement around $0.1\,\mathrm{Hz}$ compared with existing lunar seismometer concepts. Achieving this performance requires room-temperature operation, where fused-silica exhibits low mechanical loss, together with subdominant actuation noise. We demonstrate a room-temperature vacuum prototype validating the operating principle and core mechanical design, and derive requirements for a future lunar implementation capable of approaching the target sensitivity.

astro-ph.IM

Notes on Images and Communication

This is an active module taught to Bachelor's and Master's students at the University of Birmingham since 2021, covering selected topics in applied optics with an emphasis on imaging, lasers, and classical and quantum communication. The module covers both the theoretical foundations and experimental aspects of these topics, and explores a range of instrumentation examples, including optical and radio telescopes, adaptive optics, laser cutting systems, optical tweezers, laser interferometers, optical atomic clocks, optical coatings, coaxial cables and optical fibres, frequency combs, and quantum key distribution technologies.

physics.optics

Extending Ground-Based Gravitational-Wave Sensitivity to 5 Hz

Extending the sensitivity of terrestrial gravitational-wave detectors below 20 Hz is a long-standing challenge, limited by ground motion and inertial sensing noise. In this letter, we demonstrate ultra-high-vacuum compatible inertial isolation and position sensing technologies that achieve active platform stabilization down to 10 mHz. Our laser position sensors reach a sub-pm/$\sqrt{\rm Hz}$ sensitivity above 10 mHz, independent of the input light polarization, representing a 100-fold improvement over the current LIGO position sensors. In addition, our inertial sensors provide at least a factor of 5 improvement in low-frequency sensitivity compared to state-of-the-art commercial seismometers. We integrate these technologies into a LIGO-like interferometer model and predict a low-frequency sensitivity improvement of up to an order of magnitude at 10 Hz, with enhanced linearity and calibration stability. This extension increases the detection horizon for intermediate-mass black hole binaries of mass $10^3 M_\odot$ by a factor of 3. Our results provide the first experimental demonstration of a practical pathway to sub-10 Hz operation of terrestrial gravitational-wave detectors and establish key technologies for next-generation observatories such as Cosmic Explorer and Einstein Telescope.

astro-ph.IM

First result for testing semiclassical gravity effect with a torsion balance

The Schrödinger-Newton equation, a theoretical framework connecting quantum mechanics with classical gravity, predicts that gravity may induce measurable deviations in low-frequency mechanical systems-an intriguing hypothesis at the frontier of fundamental physics. In this study, we developed and operated an advanced optomechanical platform to investigate these effects. The system integrates an optical cavity with finesse over 350000 and a torsion pendulum with an ultra-low eigenfrequency of 0.6mHz, achieving a high mechanical Q-factor exceeding 50000. We collected data for 3 months and reached a sensitivity of 0.3urad/rtHz at the Schrödinger-Newton frequency of 2.5mHz where deviations from the standard quantum mechanics may occur. While no evidence supporting semiclassical gravity was found, we identify key challenges in such tests and propose new experimental approaches to advance this line of inquiry. This work demonstrates the potential of precision optomechanics to probe the interplay between quantum mechanics and gravity.

quant-ph

Sensitivity and control of a 6-axis fused-silica seismometer

We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band towards mHz frequencies. This has notable applications across a range of fields requiring access to low-frequency signals, such as seismology and climate research. We particularly highlight their potential application in gravitational-wave observatories (LIGO) in improving their observation capability of intermediate-mass black holes ($\sim 1000\,M_\odot$). The sensors are based on a near-monolithic fused-silica design consisting of a fused-silica mass and fibre, showing improved stability and robustness to tilt drifts, alignment, and control compared to all-metal or mixed metal-silica designs. We demonstrate tilt sensitivity that surpasses the best commercial alternatives in a significantly reduced footprint compared to our previous iterations of these sensors.

physics.ins-det

Merging L-shaped resonator with Michelson configuration for kilohertz gravitational-wave detection

Detection of gravitational waves in kilohertz frequency range is crucial for understanding the physical processes of binary neutron star mergers. In Ref. [Phys. Rev. X {\bf 13}, 021019 (2023)], a new interferometric configuration has been proposed, employing an L-shaped optical resonant cavity as arm cavity. This alteration enhances the detector's response to kHz signals. However, the departure from conventional Michelson configuration necessitates a redesign of its sensing and control scheme, which is currently under study. In this article, we propose replacing linear arm cavities in the conventional Michelson by the L-shaped resonator. This hybrid configuration features an enhanced response at kHz while retaining the same sensing and control scheme as the Michelson setup. At the conceptual level, it exhibits higher sensitivity in the 2-4 kHz range compared to existing configurations.

gr-qc

First results of the Laser-Interferometric Detector for Axions (LIDA)

We present the operating principle and the first observing run of a novel kind of direct detector for axions and axion-like particles in the galactic halo. Sensitive to the polarisation rotation of linearly polarised laser light induced by an axion field, our experiment is the first detector of its kind collecting scientific data. We discuss our current peak sensitivity of $1.51\times 10^{-10}$ $\text{GeV}^{-1}$ (95 % confidence level) to the axion-photon coupling strength in the axion mass range of $1.97$-$2.01$ $\text{neV}$ which is, for instance, motivated by supersymmetric grand-unified theories. We also report on effects that arise in our high-finesse in-vacuum cavity at an unprecedented optical continuous-wave intensity of $4.7$ $\text{MW/cm}^2$. Our detector already belongs to the most sensitive direct searches within its measurement band, and our results pave the way towards surpassing the current sensitivity limits in the mass range from $10^{-8}$ $\text{eV}$ down to $10^{-16}$ $\text{eV}$ via quantum-enhanced laser interferometry.

astro-ph.CO

Approaches of frequency-dependent squeezing for the low frequency detector of Einstein Telescope

The quantum noise in gravitational-wave detectors can be suppressed in a broadband by frequency-dependent squeezing. It usually requires one large scale filter cavity and even two, for example in the low frequency detector of Einstein Telescope, which is a detuned dual recycling Fabry-Perot Michelson interferometer. In this paper, we study the feasibility of replacing two filter cavities with a coupled-cavity, aiming to reduce the optical losses with less number of optics. It turns out this approach is only theoretically valid, however, the required parameters of the optics don't support practical implementation, which is consistent with the results in [Phys. Rev. D {\bf 101}, 082002 (2020)]. Furthermore, we investigate the viability of utilizing EPR squeezing to eliminate either one or two filter cavities in Einstein Telescope. It turns out EPR squeezing would allow to eliminate one filter cavity, and can potentially improve the detector sensitivity with the allowance of higher input squeezing level, benefiting from the longer length of the arm cavity which serves as one of the filter cavities for frequency-dependent squeezing.

quant-ph

A High-Finesse Suspended Interferometric Sensor for Macroscopic Quantum Mechanics with Femtometre Sensitivity

We present an interferometric sensor for investigating macroscopic quantum mechanics on a table-top scale. The sensor consists of pair of suspended optical cavities with a finesse in excess of 100,000 comprising 10 g fused-silica mirrors. In the current room-temperature operation, we achieve a peak sensitivity of \SI{0.5}{\fmasd} in the acoustic frequency band, limited by the readout noise. With additional suppression of the readout noise, we will be able to reach the quantum radiation pressure noise, which would represent a novel measurement of the quantum back-action effect. Such a sensor can eventually be utilised for demonstrating macroscopic entanglement and testing semi-classical and quantum gravity models.

quant-ph

DarkGEO: A Large-Scale Laser-Interferometric Axion Detector

Axions and axion-like particles (ALPs) are leading candidates for dark matter. They are well motivated in many extensions of the Standard Model and supported by astronomical observations. We propose an iterative transformation of the existing facilities of the gravitational-wave detector and technology testbed GEO600, located near Ruthe in Germany, into a kilometre-scale upgrade of the laser-interferometric axion detector LIDA. The final DarkGEO detector could search for coincident signatures of axions and ALPs and significantly surpass the current constraints of both direct searches and astrophysical observations in the measurement band from $10^{-16}$ to $10^{-8}$ $\text{eV}$. We discuss realistic parameters and design sensitivities for the configurations of the different iteration steps as well as technical challenges known from the first LIDA results. The proposed DarkGEO detector will be well suited to probe the parameter space associated with predictions from theoretical models, like grand-unified theories, as well as from astrophysical evidence, like the cosmic infrared background.

astro-ph.CO

Sensing and control scheme for the inteferometer configuration with an L-shaped resonator

The detection of high-frequency gravitational waves around kHz is critical to understanding the physics of binary neutron star mergers. A new interferometer design has been proposed in [Phys. Rev. X {\bf 13}, 021019 (2023)], featuring an L-shaped optical resonator as the arm cavity, which resonantly enhances kHz gravitational-wave signals. This new configuration has the potential to achieve better high-frequency sensitivity than the dual-recycled Fabry-Perot Michelson. In this article, we propose a sensing and control scheme for this configuration. Despite having the same number of length degrees of freedom as the dual-recycled Fabry-Perot Michelson, the new configuration requires one less degree of freedom to be controlled due to the degeneracy of two length degrees of freedom at low frequencies. We has also shown that introducing the Schnupp asymmetry is ineffective for controlling the signal-recycling cavity length. Therefore, we propose adding control fields from the dark port to control this auxiliary degree of freedom.

astro-ph.IM

Photon counting for axion interferometry

Axions and axion-like particles are well-motivated dark matter candidates. We propose an experiment that uses single photon detection interferometry to search for axions and axion-like particles in the galactic halo. We show that photon counting with a dark rate of 6E-6 Hz can improve the quantum sensitivity of axion interferometry by a factor of 50 compared to the quantum-enhanced heterodyne readout for 5-m long optical resonators. The proposed experimental method has the potential to be scaled up to kilometer-long facilities, enabling the detection or setting of constraints on the axion-photon coupling coefficient of 1E-17 - 1E-16 GeV-1 for axion masses ranging from 0.1 to 1 neV.

physics.ins-det

Design and sensitivity of a 6-axis seismometer for gravitational wave observatories

We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localisation of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force.

physics.ins-det

Nonlinearities in Long-Range Compact Michelson Interferometers

Compact Michelson interferometers are well positioned to replace existing displacement sensors in the readout of seismometers and suspension systems, such as those used in contemporary gravitational-wave detectors. Here, we continue our previous investigation of a customised compact displacement sensor built by SmarAct, which operated on the principle of deep frequency modulation. The focus of this paper is on the linearity of this device. We show the three primary sources of nonlinearity that arise in the sensor -- residual ellipticity, intrinsic distortion of the Lissajous figure, and distortion caused by exceeding the velocity limit imposed by the demodulation algorithm. We verify the theoretical models through an experimental demonstration designed to maximise the nonlinear noise to dominate regions of the readout's power spectrum. We finally simulate the effect that these nonlinearities are likely to have if implemented in the readout of the Advanced LIGO suspensions and show that the noise nonlinearities should not dominate across the key sub-\SI{10}{\Hz} frequency band.

physics.ins-det

A Gravitational Wave Detector for Post Merger Neutron Stars: Beyond the Quantum Loss Limit of Michelson Fabry Perot Interferometer

Advanced gravitational-wave detectors that have made groundbreaking discoveries are Michelson interferometers with resonating optical cavities as their arms. As light travels at finite speed, these cavities are optimal for enhancing signals at frequencies below their bandwidth frequency. A small amount of optical loss will, however, significantly impact the high-frequency signals which are not optimally amplified. We find an elegant interferometer configuration with an "L-resonator" as the core, significantly surpassing the loss limited sensitivity of dual recycled Fabry Perot Michelson interferometers at high frequencies. Following this concept, we provide a broadband design of a 25 km detector with outstanding sensitivity between 2-4 kHz. We have performed Monte-Carlo population studies of binary neutron star mergers, given the most recent merger rate from the GWTC-3 catalog and several representative neutron star equations of state. We find that the new interferometer configuration significantly outperforms other third-generation detectors by a factor of 3 to 7 in the signal-to-noise ratio of the post-merger signal. Assuming a detection threshold with signal-to-noise ratio >5 and for the cases we have explored, the new design is the only detector that confidently achieves a detection rate larger than one per year, with the rate being 1 to 30 events per year.

gr-qc

Design of a tabletop interferometer with quantum amplification

The sensitivity of laser interferometers is fundamentally limited by the quantum nature of light. Recent theoretical studies have opened a new avenue to enhance their quantum-limited sensitivity by using active parity-time-symmetric and phase-insensitive quantum amplification. These systems can enhance the signal response without introducing excess noise in the ideal case. However, such active systems must be causal, stable, and carefully tuned to be practical and applicable to precision measurements. In this paper, we show that phase-insensitive amplification in laser interferometers can be implemented in a tabletop experiment. The layout consists of two coupled cavities and an active medium comprised of a silicon nitride membrane and an auxiliary pump field. Our design relies on existing membrane and cryogenic technology and can demonstrate three distinct features: (i) the self-stabilized dynamics of the optical system, (ii) quantum enhancement of its sensitivity in the presence of the amplifier, and (iii) optical control of the amplifier gain. These features are needed to enhance the sensitivity of future interferometric gravitational-wave and axion detectors.

quant-ph

Compact Michelson interferometers with subpicometer sensitivity

The network of interferometric gravitational-wave observatories has successfully detected tens of astrophysical signals since 2015. In this paper, we experimentally investigate compact sensors that have the potential to improve the sensitivity of gravitational-wave detectors to intermediate-mass black holes. We use only commercial components, such as sensing heads and lasers, to assemble the setup and demonstrate its subpicometer precision. The setup consists of a pair of Michelson interferferometers that use deep frequency modulation techniques to obtain a linear, relative displacement readout over multiple interference fringes. We implement a laser-frequency stabilisation scheme to achieve a sensitivity of 0.3\,$\text{pm} / \sqrt{\text{Hz}}$ above 0.1\,Hz. The device has also the potential to improve other experiments, such as torsion balances and commercial seismometers.

physics.ins-det

Active platform stabilisation with a 6D seismometer

We demonstrate the control scheme of an active platform with a six degree of freedom (6D) seismometer. The inertial sensor simultaneously measures translational and tilt degrees of freedom of the platform and does not require any additional sensors for the stabilisation. We show that a feedforward cancellation scheme can efficiently decouple tilt-to-horizontal coupling of the seismometer in the digital control scheme. We stabilise the platform in the frequency band from 250 mHz up to 10 Hz in the horizontal degrees of freedom and achieve a suppression factor of 100 around 1 Hz. Further suppression of ground vibrations was limited by the non-linear response of the piezo actuators of the platform and by its limited range (5 μm). In this paper we discuss the 6D seismometer, its control scheme, and the limitations of the test bed.

astro-ph.IM