SearcharxivSearch

arXiv subjects

Denis Mourard

Publications and source records attributed to Denis Mourard.

At least 19 recordsLinked to original sources

Interferometric Survey of Stellar Parameters: Towards homogeneous FGK stars parameters and surface-brightness color relation in the context of PLATO space mission

The estimation of stellar angular diameters can be performed from the surface brightness - color relation (SBCR) and photometry. The SBCR have been considered by the PLATO space mission as an independent empirical alternative for estimating stellar radii of FGK stars. In this context, we have implemented an homogeneous approach not only for calibrating the SBCR for FGK-IV/V stars but, also for determining their fundamental parameters in order to place the stars reliably on the HR diagram and to study their impact on the SBCR. We have performed interferometric observations of 18 quiescent FGK-IV/V stars in the Gaia color range of $3.088 \leq G \leq 5.498$. For the first time, we used 3 different interferometers operating in the $R$, $H$ , and $K$ bands to measure polychromatic limb-darkened angular diameters (LDAD). In parallel, by using public domain spectra we have estimated the stellar parameters ($T_{eff}$, $log g$ and Z) by using the open python tool iSpec. We achieved an average accuracy of 2.3% for the LDAD based on polychromatic observations. However, we have observed that our SBCR does not follow the calibration of the relation between surface brightness and color in Gaia found in the literature. Furthermore, we found that $log g$ and $Z$ have no impact on the SBC relation; given the characteristics of our sample of quiescent stars, it constitutes an ideal set of targets for conducting a new SBCR calibration within the framework of the PLATO space mission. In this context, we reported a SBCR calibration with $\sigma_{RMS} = $ 0.012, 0.009, 0.009 in the $G, G_{BP}$ and $G_{RP}$ Gaia bands, respectively. This article is part of a series of papers reporting the first results obtained using a polychromatic approach to measure LDAD, employing a fully homogeneous methodology for both determining the fundamental parameters of stars and measuring the LDAD, $\theta_{LD}$.

astro-ph.SR

On-sky demonstration of dual-field interferometry at the CHARA Array

Dual-field interferometry uses a bright reference star for real-time fringe tracking, allowing a second beam combiner to record long coherent integrations on a fainter off-axis science target. At the Center for High Angular Resolution Astronomy (CHARA) Array, we implement this mode using the six-telescope MIRC-X and MYSTIC beam combiners in the H and K bands, respectively. We first demonstrated this capability in summer 2025 on the hierarchical triple $\alpha$~Piscium. MIRC-X tracked component A in the $H$ band, while MYSTIC observed component B in the K band, resolving the 7~mas Ba--Bb subsystem and measuring the relative astrometry of the 1.85~arcsec A--B pair with an uncertainty of 234~$\mu$as. Here, we describe subsequent phase-tracking testing, preliminary sensitivity simulations, and planned instrumental upgrades aimed at extending this mode to faint off-axis science targets.

astro-ph.IM

Pre-nova Observations of T CrB: A view from the CHARA Array

T CrB is a symbiotic recurrent nova consisting of a red giant and white dwarf with recent eruptions in 1866 and 1946 and an anticipated eruption in the mid 2020s. We report CHARA Array observations obtained with MIRC-X (H -band) and MYSTIC (K-band) in 2022-2025. We fit limb darkened disk models constrained with literature limb darkening coefficients to the squared visibilities as only the first visibility lobe is sampled. The average limb darkened diameter of the star across these epochs is $0.70\pm0.04$ mas in H-band and $0.72\pm0.07$ mas in K-band. Adopting a distance of $914^{+24}_{-22}$ pc, the stellar radius is $69\pm5~R_{\odot}$ in H-band and $71\pm8~R_{\odot}$ in K-band. This is consistent with filling a Roche lobe volume radius of $71~R_{\odot}$ inferred from published orbital solutions. These measurements provide a pre-eruption angular diameter and support a Roche lobe filling donor.

astro-ph.SR

CHARA Array Delay Lines: Upgrades, Performance and Future Directions

Long baseline optical and infrared interferometric arrays achieve high angular resolution and enable detailed astrophysical measurements. Interferometers have enabled observations of stars at various stages of evolution, as well as studies of binary stars, circumstellar disks, and active galactic nuclei. The CHARA Array is a long-baseline interferometric array at the Mount Wilson Observatory, USA. At the core of CHARA operations are the delay lines, which equalize the optical path length for all telescopes as the Earth rotates and compensate for optical path variations induced by atmospheric turbulence. We report recent upgrades and performance of the CHARA Array optical delay lines for high-precision interferometric observations. The legacy system had been operational for over two decades, and it was increasingly difficult to acquire replacement parts. Beginning in mid-2021, the control system underwent a major upgrade, replacing the aging VME-based architecture with a modern hybrid FPGA and Linux-based system; this modernization continued through the end of 2024. We describe hardware/software changes, the servo architecture, and lab/on-sky performance. The upgraded system achieves residual delay line cart tracking errors of $\sim12$~nm, the same level as the legacy system, and a control bandwidth of 100-130~Hz, allowing fringe tracking across the R, H, and K bands. Initial commissioning revealed key issues such as metrology time-tick jitter and vibration-induced visibility loss, which were diagnosed and resolved. We note ongoing and future efforts to extend baselines up to 1~km and support advanced observing modes such as dual-field interferometry and nulling. This paper is a reference for current and future use of the CHARA Array and for next-generation instrument design.

astro-ph.IM

Open loop calibration and closed loop non-perturbative estimation of the lateral errors of an adaptive optics system: examples with GRAVITY+ and CHARA experimental data

Performances of an adaptive optics (AO) system are directly linked with the quality of its alignment. During the instrument calibration, having open loop fast tools with a large capture range are necessary to quickly assess the system misalignment and to drive it towards a state allowing to close the AO loop. During operation, complex systems are prone to misalignments (mechanical flexions, rotation of optical elements, etc.) that potentially degrade the AO performances, creating a need for a monitoring tool to tackle their driftage. In this work, we first present an improved perturbative method to quickly assess large lateral errors in open loop. It uses the spatial correlation of the measured interaction matrix of a limited number of 2D spatial modes with a synthetic model. Then, we introduce a novel solution to finely measure and correct these lateral errors via the closed loop telemetry. Non-perturbative, this method consequently does not impact the science output of the instrument. It is based on the temporal correlation of 2D spatial frequencies in the deformable mirror commands. It is model-free (no need of an interaction matrix model) and sparse in the Fourier space, making it fast and easily scalable to complex systems such as future extremely large telescopes. Finally, we present some results obtained on the development bench of the GRAVITY+ extreme AO system (Cartesian grid, 1432 actuators). In addition, we show with on-sky results gathered with CHARA and GRAVITY/CIAO that the method is adaptable to non-conventional AO geometries (hexagonal grids, 60 actuators).

eess.SP

Recent and Upcoming Upgrades for MIRC-X and MYSTIC on the CHARA Array

MIRC-X and MYSTIC are six-telescope near-infrared beam (1.08-2.38 ${\mu}$m) combiners at the CHARA Array on Mt Wilson CA, USA. Ever since the commissioning of MIRC-X (J and H bands) in 2018 and MYSTIC (K bands) in 2021, they have been the most popular and over-subscribed instruments at the array. Observers have been able to image stellar objects with sensitivity down to 8.1 mag in H and 7.8 mag in K-band under the very best conditions. In 2022 MYSTIC was upgraded with a new ABCD mode using the VLTI/GRAVITY 4-beam integrated optics chip, with the goal of improving the sensitivity and calibration. The ABCD mode has been used to observe more than 20 T Tauri stars; however, the data pipeline is still being developed. Alongside software upgrades, we detail planned upgrades to both instruments in this paper. The main upgrades are: 1) Adding a motorized filter wheel to MIRC-X along with new high spectral resolution modes 2) Updating MIRC-X optics to allow for simultaneous 6T J+H observations 3) Removing the warm window between the spectrograph and the warm optics in MYSTIC 4) Adding a 6T ABCD mode to MIRC-X in collaboration with CHARA/SPICA 5) Updating the MIRC-X CRED-ONE camera funded by Prof. Kraus from U. Exeter 6) Carrying out science verification of the MIRC-X polarization mode 7) Developing new software for ABCD-mode data reduction and more efficient calibration routines. We expect these upgrades to not only improve the observing experience, but also increase the sensitivity by 0.4 mag in J+H-bands, and 1 mag in K-band.

astro-ph.IM

2023 Astrophotonics Roadmap: pathways to realizing multi-functional integrated astrophotonic instruments

Photonics offer numerous functionalities that can be used to realize astrophotonic instruments. The most spectacular example to date is the ESO Gravity instrument at the Very Large Telescope in Chile. Integrated astrophotonic devices stand to offer critical advantages for instrument development, including extreme miniaturization, as well as integration, superior thermal and mechanical stabilization owing to the small footprint, and high replicability offering cost savings. Numerous astrophotonic technologies have been developed to address shortcomings of conventional instruments to date, including for example the development of photonic lanterns, complex aperiodic fiber Bragg gratings, complex beam combiners to enable long baseline interferometry, and laser frequency combs for high precision spectral calibration of spectrometers. Despite these successes, the facility implementation of photonic solutions in astronomical instrumentation is currently limited because of (1) low throughputs from coupling to fibers, coupling fibers to chips, propagation and bend losses, device losses, etc, (2) difficulties with scaling to large channel count devices needed for large bandwidths and high resolutions, and (3) efficient integration of photonics with detectors, to name a few. In this roadmap, we identify 24 areas that need further development. We outline the challenges and advances needed across those areas covering design tools, simulation capabilities, fabrication processes, the need for entirely new components, integration and hybridization and the characterization of devices. To realize these advances the astrophotonics community will have to work cooperatively with industrial partners who have more advanced manufacturing capabilities. With the advances described herein, multi-functional instruments will be realized leading to novel observing capabilities for both ground and space platforms.

astro-ph.IM

CHARA/SPICA: a 6-telescope visible instrument for the CHARA Array

With a possible angular resolution down to 0.1-0.2 millisecond of arc using the 330 m baselines and the access to the 600-900 nm spectral domain, the CHARA Array is ideally configured for focusing on precise and accurate fundamental parameters of stars. CHARA/SPICA (Stellar Parameters and Images with a Cophased Array) aims at performing a large survey of stars all over the Hertzsprung-Russell diagram. This survey will also study the effects of the different kinds of variability and surface structure on the reliability of the extracted fundamental parameters. New surface-brightness-colour relations will be extracted from this survey, for general purposes on distance determination and the characterization of faint stars. SPICA is made of a visible 6T fibered instrument and of a near-infrared fringe sensor. In this paper, we detail the science program and the main characteristics of SPICA-VIS. We present finally the initial performance obtained during the commissioning.

astro-ph.IM

SPICA-FT: The new fringe tracker of the CHARA array

SPICA-FT is part of the CHARA/SPICA instrument which combines a visible 6T fibered instrument (SPICAVIS) with a H-band 6T fringe sensor. SPICA-FT is a pairwise ABCD integrated optics combiner. The chip is installed in the MIRC-X instrument. The MIRC-X spectrograph could be fed either by the classical 6T fibered combiner or by the SPICA-FT integrated optics combiner. SPICA-FT also integrates a dedicated fringe tracking software, called the opd-controller communicating with the main delay line through a dedicated channel. We present the design of the integrated optics chip, its implementation in MIRC-X and the software architecture of the group-delay and phase-delay control loops. The final integrated optics chip and the software have been fully characterized in the laboratory. First on-sky tests of the integrated optics combiner began in 2020. We continue the on-sky tests of the whole system (combiner + software) in Spring and Summer 2022. We present the main results, and we deduce the preliminary performance of SPICA-FT.

astro-ph.IM

The SAPP pipeline for the determination of stellar abundances and atmospheric parameters of stars in the core program of the PLATO mission

We introduce the SAPP (Stellar Abundances and atmospheric Parameters Pipeline), the prototype of the code that will be used to determine parameters of stars observed within the core program of the PLATO space mission. The pipeline is based on the Bayesian inference and provides effective temperature, surface gravity, metallicity, chemical abundances, and luminosity. The code in its more general version can have a much wider range of applications. It can also provide masses, ages, and radii of stars and can be used for stars of stellar types not targeted by the PLATO core program, such as red giants. We validate the code on a set of 27 benchmark stars that includes 19 FGK-type dwarfs, 6 GK-type sub-giants, and 2 red giants. Our results suggest that combining various observables is the optimal approach, as it allows to break degeneracies between different parameters and yields more accurate values of stellar parameters and more realistic uncertainties. For the PLATO core sample, we obtain a typical uncertainty of 27 ($\rm{syst.}$) $\pm$ 37 ($\rm{stat.}$) K for T$_{\rm{eff}}$, 0.00 $\pm$ 0.01 dex for log$g$, 0.02 $\pm$ 0.02 dex for metallicity [Fe/H], -0.01 $\pm$ 0.03 R$_\odot$ for radii, -0.01 $\pm$ 0.05 M$_\odot$ for stellar masses, and -0.14 $\pm$ 0.63 Gyrs for ages. We also show that the best results are obtained by combining the $\nu_{max}$ scaling relation and stellar spectra. This resolves the notorious problem of degeneracies, which is particularly important for F-type stars.

astro-ph.SR

Compensation of differential dispersion: application to multiband stellar interferometry

With the aim of pushing the limiting magnitude of interferometric instruments, the need for wide-band detection channels and for a coordinated operation of different instruments has considerably grown in the field of long-baseline interferometry. For this reason, the Center for High Angular Resolution Astronomy (CHARA), an array of six telescopes, requires a new configuration of longitudinal dispersion compensators to keep the fringe contrast above 95 per cent simultaneously in all spectral bands, while preserving the transmission above 85 per cent. In this paper, we propose a new method for defining the longitudinal dispersion compensators (LDC) suited for multiband observations. A literal approximation of the contrast loss resulting from the dispersion residues enables us to define a general criterion for fringe contrast maximization on several bands simultaneously. The optimization of this criterion leads to a simple solution with only two LDC stages per arm and existing differential delay lines, to the glass choice and a simple linear formula for thickness control of all these media. A refined criterion can also take into account glass transmission. After presenting this criterion, we give the optimal solution (medium, configuration) and its expected performance for the planned observing modes on CHARA.

astro-ph.IM

Directly Determined Properties of HD 97658 from Interferometric Observations

We conducted interferometric observations with the CHARA Array of transiting super-Earth host HD 97658 and measured its limb-darkened angular diameter to be $θ_{\text{LD}}=0.314\pm0.004$ mas. The combination of the angular diameter with the Gaia EDR3 parallax value with zero-point correction ($π=46.412\pm0.022$ mas, $d=21.546\pm0.011$ pc) yields a physical radius of $R_\star=0.728\pm0.008$ $R_\odot$. We also measured the bolometric flux of the star to be $F_\text{bol}=2.42\pm 0.05\times 10^{-8}$erg s$^{-1}$ cm$^{-2}$, which, together with angular size, allows a measurement of the effective temperature $T_{\text{eff}}=5212\pm43$ K. Our directly determined physical stellar properties are in good agreement with previous estimates derived from spectroscopy. We used our measurements in combination with stellar evolutionary models and properties of the transit of HD 97658 b to determine the mass and age of HD 97658 as well as constrain the properties of the planet. Our results and our analysis of the TESS lightcurve on the planet (TOI-1821) corroborate previous studies of this system with tighter uncertainties.

astro-ph.SR

Progress on the calibration of surface brightness-color relations for early- and late-type stars

Surface brightness-color relations (SBCRs) are used for estimating angular diameters and deriving stellar properties. They are critical to derive extragalactic distances of early-type and late-type eclipsing binaries or, potentially, for extracting planetary parameters of late-type stars hosting planets. Various SBCRs have been implemented so far, but strong discrepancies in terms of precision and accuracy still exist in the literature. We aim to develop a precise SBCR for early-type B and A stars using selection criteria, based on stellar characteristics, and combined with homogeneous interferometric angular diameter measurements. We also improve SBCRs for late-type stars, in particular in the Gaia photometric band. We observed 18 early-type stars with the VEGA interferometric instrument, installed on the CHARA array. We then applied additional criteria on the photometric measurements, together with stellar characteristics diagnostics in order to build the SBCRs. We calibrated a SBCR for subgiant and dwarf early-type stars. The RMS of the relation is $σ_{F_{V_{0}}} = 0.0051\,$mag, leading to an average precision of 2.3% on the estimation of angular diameters, with 3.1% for $V-K < -0.2\,$mag and 1.8% for $V-K > -0.2\,$mag. We found that the conversion between Johnson-$K$ and 2MASS-$K_s$ photometries is a key issue for early-type stars. Following this result, we have revisited our previous SBCRs for late-type stars by calibrating them with either converted Johnson-$K$ or 2MASS-$K_s$ photometries. We also improve the calibration of these SBCRs based on the Gaia photometry. The expected precision on the angular diameter using our SBCRs for late-type stars ranges from 1.0% to 2.7%. By reaching a precision of 2.3% on the estimation of angular diameters for early-type stars, significant progress has been made to determine extragalactic distances using early-type eclipsing binaries.

astro-ph.SR

CHARA Array adaptive optics: complex operational software and performance

The CHARA Array is the longest baseline optical interferometer in the world. Operated with natural seeing, it has delivered landmark sub-milliarcsecond results in the areas of stellar imaging, binaries, and stellar diameters. However, to achieve ambitious observations of faint targets such as young stellar objects and active galactic nuclei, higher sensitivity is required. For that purpose, adaptive optics are developed to correct atmospheric turbulence and non-common path aberrations between each telescope and the beam combiner lab. This paper describes the AO software and its integration into the CHARA system. We also report initial on-sky tests that demonstrate an increase of scientific throughput by sensitivity gain and by extending useful observing time in worse seeing conditions. Our 6 telescopes and 12 AO systems with tens of critical alignments and control loops pose challenges in operation. We describe our methods enabling a single scientist to operate the entire system.

astro-ph.IM

From the stellar properties of HD219134 to the internal compositions of its transiting exoplanets

The harvest of exoplanet discoveries has opened the area of exoplanet characterisation. But this cannot be achieved without a careful analysis of the host star parameters. The system of HD219134 hosts two transiting exoplanets and at least two additional non-transiting exoplanets. We used the VEGA/CHARA interferometer to measure the angular diameter of HD219134, leading to a stellar radius of $R_{\star}=0.726\pm0.014 R_{\odot}$. We also derived the stellar density from the transits light curves ($ρ_{\star}=1.82\pm0.19 ρ_{\odot}$), which finally gives a direct estimate of the mass ($M_{\star}=0.696\pm0.078 M_{\odot}$) with a correlation of 0.46 between $R_{\star}$ and $M_{\star}$. This new mass is smaller than that derived from the C2kSMO stellar evolutionary model, which provides a mass range of 0.755$-$0.810 ($\pm 0.040$) $M_{\odot}$. This allows us to infer the mass, radius and density of the two transiting exoplanets of the system. We then use an inference model to obtain the internal parameters of these two transiting exoplanets. Moreover, we find that planet $b$ and $c$ have smaller radii than previously estimated ($1.500\pm0.057$ and $1.415\pm0.049 R_{\oplus}$, respectively); this clearly puts these planets out of the gap in the exoplanetary radii distribution and validates their super-Earth nature. Planet $b$ is more massive than planet $c$, but possibly less dense. We investigate whether this could be caused by partial melting of the mantle and find that tidal heating due to non-zero eccentricity of planet $b$ may be powerful enough. The system of HD219134 constitutes a very valuable benchmark for both stellar physics and exoplanetary science. The direct determination of the stellar density, radius and mass should be more extensively applied to provide accurate exoplanets properties and calibrate stellar models.

astro-ph.EP

Perspectives of a visible instrument on the VLTI

In this paper we present the most promising science cases for a new generation visible instrument on the VLTI and the conceptual idea for the instrumental configuration. We also present a statistical study of the potential targets that may be accessible for the different classes of objects and for the required spectral resolutions.

astro-ph.IM

The peculiar fast-rotating star 51 Oph probed by VEGA/CHARA

Stellar rotation is a key in our understanding of both mass-loss and evolution of intermediate and massive stars. It can lead to anisotropic mass-loss in the form of radiative wind or an excretion disk. We wished to spatially resolve the photosphere and gaseous environment of 51 Oph, a peculiar star with a very high vsin(i) of 267km s$^{-1}$ and an evolutionary status that remains unsettled. It has been classified by different authors as a Herbig, a $β$ Pic, or a classical Be star. We used the VEGA visible beam combiner installed on the CHARA array that reaches a submilliarcsecond resolution. Observation were centered on the H$α$ emission line. We derived, for the first time, the extension and flattening of 51 Oph photosphere. We found a major axis of $θ_{\mathrm{eq}}$=8.08$\pm$0.70$R_\odot$ and a minor axis of $θ_{\mathrm{pol}}$=5.66$\pm$0.23$R_\odot$ . This high photosphere distortion shows that the star is rotating close to its critical velocity. Finally, using spectro-interferometric measurements in the H$ α$ line, we constrained the circumstellar environment geometry and kinematics and showed that the emission is produced in a 5.2$\pm$2R$_{*}$ disk in Keplerian rotation. From the visible point of view, 51 Oph presents all the features of a classical Be star: near critical-rotation and double-peaked H$α$ line in emission produced in a gaseous disk in Keplerian rotation. However, this does not explain the presence of dust as seen in the mid-infrared and millimeter spectra, and the evolutionary status of 51 Oph remains unsettled.

astro-ph.EP

Science cases for a visible interferometer

High spatial resolution is the key for the understanding various astrophysical phenomena. But even with the future E-ELT, single dish instruments are limited to a spatial resolution of about 4 mas in the visible. For the closest objects within our Galaxy most of the stellar photosphere remains smaller than 1 mas. With the success of long baseline interferometry these limitations were soom overcome. Today low and high resolution interferometric instruments on the VLTI and CHARA offer an immense range of astrophysical studies. Combining more telescopes and moving to visible wavelengths broadens the science cases even more. With the idea of developing strong science cases for a future visible interferometer, we organized a science group around the following topics: pre-main sequence and main sequence stars, fundamental parameters, asteroseismology and classical pulsating stars, evolved stars, massive stars, active galactic nuclei (AGNs) and imaging techniques. A meeting was organized on the 15th and 16th of January, 2015 in Nice with the support of the Action Specific in Haute Resolution Angulaire (ASHRA), the Programme National en Physique Stellaire (PNPS), the Lagrange Laboratory and the Observatoire de la Cote d'Azur, in order to present these cases and to discuss them further for future visible interferometers. This White Paper presents the outcome of the exchanges. This book is dedicated to the memory of our colleague Olivier Chesneau who passed away at the age of 41.

astro-ph.SR