Dennis Klomp

Publications and source records attributed to Dennis Klomp.

2 recordsLinked to original sources

Diffusion MRI preprocessing affects ADC estimation and automatic PI-RADS v2.1 classification in bi-parametric prostate MRI

Diffusion-weighted imaging (DWI) is acquired as part of bi-parametric prostate MRI, but suffers from artifacts that degrade downstream quantitative and diagnostic performance. While DWI preprocessing is standard in brain imaging, its adoption in prostate imaging remains limited and lacks standardized pipelines. This study investigated the effect of different DWI preprocessing strategies on apparent diffusion coefficient (ADC) estimation and automatic Prostate Imaging Reporting and Data System (PI-RADS) classification. 268 cases were derived from the fastMRI prostate cohort by sequentially applying denoising, Gibbs-ringing correction, and diffeomorphic registration for susceptibility distortion correction. ADC maps were compared using linear least squares (LLS) and iteratively-weighted LLS (IWLLS). A 3-class DenseNet classifier was trained to predict PI-RADS scores from multi-channel MRI inputs. ADC analysis revealed statistically significant differences across preprocessing pipelines, with LLS and IWLLS producing numerically equivalent maps. Linear relationships between ADC values were preserved across most datasets (PCC ~0.99), while distortion correction realigned DWI to T2w anatomy and altered ADC values accordingly (PCC ~0.90). Classification showed the best AUROC and sensitivity for high-risk PI-RADS classes in the fully processed dataset. False-negative analysis revealed this dataset produced the least overconfident incorrect predictions on high-risk classes, which is a desirable property for clinical triage. DWI preprocessing, particularly distortion correction, enhances both ADC map quality and the predictive power of deep learning models for PI-RADS classification, supporting the need for optimized preprocessing pipelines in prostate MRI.

eess.IV

Bilateral breast gradient insert prototype for strong diffusion encoding at 3T

Purpose: Diffusion MRI has shown promise for breast cancer screening, lesion characterization,and treatment response monitoring without contrast agents, but further translation is constraint by the gradient performance of conventional systems. The aim of this work is to develop a single-axis high performance bilateral plug-and-play breast gradient insert to enable strong-gradient diffusion MRI. Methods: An in-house breast gradient insert and bed-tabletop was constructed entirely from commercially available materials, providing a cost-effective solution compatible with existing MRI systems. Its wiring pattern was optimized for torque and force balancing, power dissipation, and target field performance. Evaluation included gradient field characterization, peripheral nerve stimulation simulation verification, and temperature and eddy current assessment. The setup was used for imaging of a diffusion phantom based on soy lecithin across a range of b-values. Results: Gradient efficiency reached 2.8 mT/m/A, enabling local strengths up to 1850 mT/m (660 A). No peripheral nerve stimulation was observed during tests on five healthy volunteers. Eddy currents were successfully characterized employed in standard correction methods. Imaging showed the feasibility of $b = 10 000 s/mm^2$ acquisitions at TE = 78 ms versus 161 ms with scanner gradients. Conclusion: This work demonstrates a dedicated bilateral breast gradient insert for safe and feasible strong-gradient breast diffusion MRI, and represents a first step toward dedicated hardware for breast cancer detection and characterization without contrast agents.

physics.med-ph