Searcharxiv⌕ Search

arXiv subjects

Dennis M. J. van de Sande

Publications and source records attributed to Dennis M. J. van de Sande.

7 recordsLinked to original sources

Physics-Informed Sylvester Normalizing Flows for Bayesian Inference in Magnetic Resonance Spectroscopy

Magnetic resonance spectroscopy (MRS) is a non-invasive technique to measure the metabolic composition of tissues, offering valuable insights into neurological disorders, tumor detection, and other metabolic dysfunctions. However, accurate metabolite quantification is hindered by challenges such as spectral overlap, low signal-to-noise ratio, and various artifacts. Traditional methods like linear-combination modeling are susceptible to ambiguities and commonly only provide a theoretical lower bound on estimation accuracy in the form of the Cramér-Rao bound. This work introduces a Bayesian inference framework using Sylvester normalizing flows (SNFs) to approximate posterior distributions over metabolite concentrations, enhancing quantification reliability. A physics-based decoder incorporates prior knowledge of MRS signal formation, ensuring realistic distribution representations. We validate the method on simulated 7T proton MRS data, demonstrating accurate metabolite quantification, well-calibrated uncertainties, and insights into parameter correlations and multi-modal distributions.

stat.ML↗

The 2024 MRSI Data Processing and Quantification Challenge Synthetic Dataset

Synthetic data is central to magnetic resonance spectroscopy method development because they provide ground truths for software validation, reproducible benchmarking, and machine- and deep-learning training. In MRSI, synthetic data must capture spatially varying anatomy, field inhomogeneity, nuisance signals, and measurement effects. The 2024 MRSI Data Processing and Quantification Challenge Synthetic Dataset is a simulated 3T brain FID-MRSI resource with ground-truth metabolite maps developed as a controlled testbed for MRSI processing and quantification methods. Subject-specific simulations used anatomical images and field maps from Human Connectome Project subjects. Tissue masks, quantum-mechanically simulated metabolite basis functions, in vivo-derived macromolecular components, Bloch-simulated post-WET residual water, registered in vivo lipid signals, spectral baseline, $B_0$-dependent frequency shifts, Voigt lineshape variations, and complex Gaussian noise were combined in a forward model. Water and lipid signals were synthesized on a high-resolution grid and Fourier-truncated to the final echo-planar spectroscopic imaging grid to model the finite spatial point spread function. This resource has 24 training and 8 testing datasets containing contaminated FID-MRSI data, anatomical images, $B_0$ maps, metadata, and ground-truth metabolite and component signals. Forward-model parameters are documented, including tissue-specific metabolite concentrations and relaxation times, macromolecular amplitude ratios, the water model, noise, and field-inhomogeneity ranges. This synthetic benchmark supports development and comparison of MRSI processing, nuisance-signal removal, and metabolite-quantification methods, while enabling method evaluation. It illustrates how characterized synthetic data can support rigorous evaluation when ground truth is difficult or impossible to obtain.

physics.med-ph↗

Synthetic Data in MR Spectroscopy: Current Practices, Applications, and Considerations

The use of synthetic data has emerged as an essential tool in Magnetic Resonance Spectroscopy (MRS) research and applications, providing advantages for optimization of acquisition, software validation, deep learning applications, and enhanced reproducibility. Importantly, synthetic data addresses challenges of limited training data availability, particularly for clinical populations, and offers controlled solutions for investigating uncertainties and unexplained variance with in vivo data. This work provides a review and evaluation of current practices in the use and generation of synthetic data within the MRS field. Conducted by the MRS Synthetic Data Working Group under the Code & Data Sharing Committee of the MRS Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM), this manuscript encompasses existing literature, supplemented by collective experience and in-house methodologies.

physics.med-ph↗

Data-driven Synthesis of Magnetic Resonance Spectroscopy Data using a Variational Autoencoder

The development of deep learning methods for magnetic resonance spectroscopy (MRS) is often hindered by limited availability of large, high-quality training datasets. While physics-based simulations are commonly used to mitigate this limitation, accurately modeling all in-vivo signal components remains challenging. In this work, we propose a data-driven framework for synthesizing in-vivo MRS data using a variational autoencoder (VAE) trained exclusively on measured single-voxel spectroscopy data. The model learns a low-dimensional latent representation of complex-valued spectra and enables generation of new samples through latent-space sampling and interpolation. The generative performance of the proposed approach is evaluated using a comprehensive set of complementary analyses, including reconstruction quality, feature-level similarity using low-dimensional embeddings, application-based signal quality metrics, and metabolite quantification agreement. The results demonstrate that the VAE accurately reconstructs dominant spectral patterns and generates synthetic spectra that occupy the same feature space as in-vivo data. In an example application targeting GABA-edited spectroscopy, augmenting limited subsets of transients with synthetic spectra improves signal quality metrics such as signal-to-noise ratio, linewidth, and shape scores. However, the results also reveal limitations of the generative approach, including under-representation of stochastic noise and reduced accuracy in absolute metabolite quantification, particularly for applications sensitive to concentration estimates. These findings highlight both potential and limitations of data-driven MRS synthesis. Beyond the proposed model, this study introduces a structured evaluation framework for generative MRS methods, emphasizing the importance of application-aware validation when synthetic data are used for downstream analysis.

physics.med-ph↗

WAND: Wavelet Analysis-based Neural Decomposition of MRS Signals for Artifact Removal

Accurate quantification of metabolites in magnetic resonance spectroscopy (MRS) is challenged by low signal-to-noise ratio (SNR), overlapping metabolites, and various artifacts. Particularly, unknown and unparameterized baseline effects obscure the quantification of low-concentration metabolites, limiting MRS reliability. This paper introduces wavelet analysis-based neural decomposition (WAND), a novel data-driven method designed to decompose MRS signals into their constituent components: metabolite-specific signals, baseline, and artifacts. WAND takes advantage of the enhanced separability of these components within the wavelet domain. The method employs a neural network, specifically a U-Net architecture, trained to predict masks for wavelet coefficients obtained through the continuous wavelet transform. These masks effectively isolate desired signal components in the wavelet domain, which are then inverse-transformed to obtain separated signals. Notably, an artifact mask is created by inverting the sum of all known signal masks, enabling WAND to capture and remove even unpredictable artifacts. The effectiveness of WAND in achieving accurate decomposition is demonstrated through numerical evaluations using simulated spectra. Furthermore, WAND's artifact removal capabilities significantly enhance the quantification accuracy of linear combination model fitting. The method's robustness is further validated using data from the 2016 MRS Fitting Challenge and in-vivo experiments.

eess.SP↗

A Review of Machine Learning Applications for the Proton Magnetic Resonance Spectroscopy Workflow

This literature review presents a comprehensive overview of machine learning (ML) applications in proton magnetic resonance spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state-of-the-art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the magnetic resonance field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in-vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field.

physics.med-ph↗