SearcharxivSearch

arXiv subjects

Desong Bian

Publications and source records attributed to Desong Bian.

12 recordsLinked to original sources

Rethink AI-based Power Grid Control: Diving Into Algorithm Design

Recently, deep reinforcement learning (DRL)-based approach has shown promisein solving complex decision and control problems in power engineering domain.In this paper, we present an in-depth analysis of DRL-based voltage control fromaspects of algorithm selection, state space representation, and reward engineering.To resolve observed issues, we propose a novel imitation learning-based approachto directly map power grid operating points to effective actions without any interimreinforcement learning process. The performance results demonstrate that theproposed approach has strong generalization ability with much less training time.The agent trained by imitation learning is effective and robust to solve voltagecontrol problem and outperforms the former RL agents.

cs.AI

On Training Effective Reinforcement Learning Agents for Real-time Power Grid Operation and Control

Deriving fast and effectively coordinated control actions remains a grand challenge affecting the secure and economic operation of today's large-scale power grid. This paper presents a novel artificial intelligence (AI) based methodology to achieve multi-objective real-time power grid control for real-world implementation. State-of-the-art off-policy reinforcement learning (RL) algorithm, soft actor-critic (SAC) is adopted to train AI agents with multi-thread offline training and periodic online training for regulating voltages and transmission losses without violating thermal constraints of lines. A software prototype was developed and deployed in the control center of SGCC Jiangsu Electric Power Company that interacts with their Energy Management System (EMS) every 5 minutes. Massive numerical studies using actual power grid snapshots in the real-time environment verify the effectiveness of the proposed approach. Well-trained SAC agents can learn to provide effective and subsecond control actions in regulating voltage profiles and reducing transmission losses.

math.OC

Online Low Frequency Oscillation Detection and Analysis System with an Ensemble Filter

The widespread deployment of phasor measurement unit (PMU) overpower systems makes it possible to monitor and analyze grid dynamics in real-time. Low-frequency oscillation is harmful to power system equipment and operation, and in the worst-case scenario may lead to cascading failures. Therefore, it is critical to detect and identify them as soon as they appear. This paper presents an online low-frequency oscillation detection and analysis (LFODA) system, which has the merit of significantly reducing the chance of false alarm via a voting schema and a time-serial filter. A novel algorithm based on density-based spatial clustering of applications with noise (DBSCAN) is proposed to classify oscillation modes as well as to group their corresponding buses/monitoring sites. Performance of the LFODA system is evaluated through experiments using both simulated and real-world PMU data.

eess.SP

Community Microgrid Planning Considering Building Thermal Dynamics

In this paper, the building thermal dynamic characteristics are introduced in the community microgrid (MG) planning model. The proposed planning model is formulated as a mixed integer linear programming (MILP) which seeks to determine the optimal deployment strategy for various distributed energy resources (DER). The objective is to minimize the annualized cost of community MG, including investment cost in DER, operation cost for dispatchable fuel-generators (DFG), energy storage system (ESS) degradation cost, energy purchasing and peak demand charge at PCC, customer discomfort cost due to the room temperature deviation and load curtailment cost. Given the slow thermal dynamic characteristics of buildings, the heating, ventilation and air-conditioning (HVAC) system in the proposed model is treated as a demand side management (DSM) component, whose dispatch commands are provided by the central MG controller. Numerical results based on a community MG comprising of 20 residential buildings demonstrate the effectiveness of the proposed planning model and the benefits of introducing the building thermal dynamic model.

math.OC

Line Outage Detection and Localization via Synchrophasor Measurement

Since transmission lines are crucial links in the power system, one line outage event may bring about interruption or even cascading failure of the power system. If a quick and accurate line outage detection and localization can be achieved, the system operator can take necessary actions in time to mitigate the negative impact. Therefore, the objective of this paper is to study a method for line outage detection and localization via synchrophasor measurements. The density of deployed phasor measurement units (PMUs) is increasing recently, which greatly improves the visibility of the power grid. Taking advantage of the high-resolution synchrophasor data, the proposed method utilizes frequency measurement for line outage detection and power change for localization. The procedure of the proposed method is given. Compared with conventional methods, it does not require the pre-knowledge on the system. Simulation study validates the effectiveness of the proposed method.

eess.SP

Adaptive Robust Energy Management Strategy for Campus-Based Commercial Buildings Considering Comprehensive Comfort Levels

Neglecting consumers' comfort always leads to failure or slow-response to demand response request. In this paper, we propose several comprehensive comfort level models for various appliances in campus-based commercial buildings (CBs). The objective of the proposed system is to minimize O\&M costs of campus-based CBs and maximize various comfort levels simultaneously under the worst-case scenarios. Adaptive robust optimization (ARO) is leveraged to handle various uncertainties within the proposed system: (i) demand response signals sending from the distribution system operator (DSO); (ii) arrival state-of-charge (SoC) conditions of plug-in electric vehicles (PEVs); (iii) power outputs of renewable energy sources (RESs); and (iv) load demand of other appliances. Benders decomposition, such as column-and-constraint generation (C\&CG) algorithm, is used to solve the reformulated NP-hard min-max problem. Extensive simulation results demonstrate the effectiveness of the proposed optimal energy management strategy for campus-based CBs in both minimizing O\&M costs and maximizing comprehensive comfort levels.

math.OC

Performance Evaluation of Communication Technologies and Network Structure for Smart Grid Applications

Design of an effective and reliable communication network supporting smart grid applications requires a selection of appropriate communication technologies and protocols. The objective of this paper is to study and quantify the capabilities of an Advanced Metering Infrastructure (AMI) to support the simultaneous operation of major smart grid functions. These include smart metering, price-induced controls, distribution automation, demand response and electric vehicle charging/discharging applications in terms of throughput and latency. OPNET is used to simulate the performance of selected communication technologies and protocols. Research findings indicate that smart grid applications can operate simultaneously by piggybacking on an existing AMI infrastructure and still achieve their latency requirements.

cs.NI

Optimal Energy Management for Commercial Buildings Considering Comprehensive Comfort Levels in a Retail Electricity Market

Demand response has been implemented by distribution system operators to reduce peak demand and mitigate contingency issues on distribution lines and substations. Specifically, the campus based commercial buildings make the major contributions to peak demand in a distribution system. Note that prior works neglect the consumers comfort level in performing demand response, which limits their applications as the incentives are not worth as compared to the loss in comfort levels for most time. Thus, a framework to comprehensively consider both operating costs and comfort levels is necessary. Moreover, distributed energy resources are widely deployed in commercial buildings such as roof top solar panels, plug in electric vehicles, and energy storage units, which bring various uncertainties to the distribution systems, i.e., output of renewable; electricity prices; arrival and departure of plug-in electric vehicles; business hour demand response signals and flexible energy demand. In this paper, we propose an optimal demand response framework to enable local control of demand-side appliances that are usually too small to participate in a retail electricity market. Several typical small demand side appliances, i.e., heating, ventilation, and air conditioning systems, electric water heaters and plug-in electric vehicles, are considered in our proposed model. Their operations are coordinated by a central controller, whose objective is to minimize the total cost and maximize the customers comfort levels for multiple commercial buildings. A scenario-based stochastic programming is leveraged to handle the aforementioned uncertainties. Numerical results based on the practical data demonstrate the effectiveness of the proposed framework. In addition, the trade off between the operation costs of commercial buildings and customers comfort levels is illustrated.

math.OC

Small-signal Stability Analysis and Performance Evaluation of Microgrids under Distributed Control

Distributed control, as a potential solution to decreasing communication demands in microgrids, has drawn much attention in recent years. Advantages of distributed control have been extensively discussed, while its impacts on microgrid performance and stability, especially in the case of communication latency, have not been explicitly studied or fully understood yet. This paper addresses this gap by proposing a generalized theoretical framework for small-signal stability analysis and performance evaluation for microgrids using distributed control. The proposed framework synthesizes generator and load frequency-domain characteristics, primary and secondary control loops, as well as the communication latency into a frequency-domain representation which is further evaluated by the generalized Nyquist theorem. In addition, various parameters and their impacts on microgrid dynamic performance are investigated and summarized into guidelines to help better design the system. Case studies demonstrate the effectiveness of the proposed approach.

eess.SY

Forced Oscillation Source Location via Multivariate Time Series Classification

Precisely locating low-frequency oscillation sources is the prerequisite of suppressing sustained oscillation, which is an essential guarantee for the secure and stable operation of power grids. Using synchrophasor measurements, a machine learning method is proposed to locate the source of forced oscillation in power systems. Rotor angle and active power of each power plant are utilized to construct multivariate time series (MTS). Applying Mahalanobis distance metric and dynamic time warping, the distance between MTS with different phases or lengths can be appropriately measured. The obtained distance metric, representing characteristics during the transient phase of forced oscillation under different disturbance sources, is used for offline classifier training and online matching to locate the disturbance source. Simulation results using the four-machine two-area system and IEEE 39-bus system indicate that the proposed location method can identify the power system forced oscillation source online with high accuracy.

eess.SP

Bilevel Optimization Based Transmission Expansion Planning Considering Phase Shifting Transformer

In this paper, the phase shifting transformer (PST) is introduced in the Transmission Expansion Planning (TEP) problem considering significant wind power integration. The proposed planning model is formulated as a bilevel program which seeks to determine the optimal strategy for the network reinforcements and the PST locations. The objective of the upper level problem is to minimize the total consumer payment, the investment cost on transmission line and PST. The lower level problems designate the electricity market clearing conditions under different load-wind scenarios. The bilevel model is transformed into a single level mixed integer linear program (MILP) by replacing each lower level problem with its primal-dual formulation. The numerical case studies based on IEEE 24-bus system demonstrate the characteristics of the proposed model. Moreover, the simulation results show that the installation of PST adds flexibility to the TEP and facilitates the integration of wind power.

math.OC

A Distributed Cooperative Control Framework for Synchronized Reconnection of a Multi-Bus Microgrid

One critical value microgrids bring to power systems is resilience, the capability of being able to island from the main grid under certain conditions and connect back when necessary. Once islanded, a microgrid must be synchronized to the main grid before reconnection to prevent severe consequences. In general, synchronization of a single machine with the grid can be easily achieved using a synchronizer. The problem becomes more challenging when it comes to a multi-bus microgrid with multiple distributed generators (DGs) and dispersed loads. All distributed generators need to be properly controlled in a coordinated way to achieve synchronization. This paper presents a novel bi-level distributed cooperative control framework for a multi-bus microgrid. In this framework, DGs work collaboratively in a distributed manner using the minimum and sparse communication. The topology of the communication network can be flexible which supports the plug-and-play feature of microgrids. Fast and deterministic synchronization can be achieved with tolerance to communication latency. Experimental results obtained from Hardware-in-the-Loop (HIL) simulation demonstrate the effectiveness of the proposed approach.

eess.SY