ECG-R1: Protocol-Guided and Modality-Agnostic MLLM for Reliable ECG Interpretation

Electrocardiography (ECG) serves as an indispensable diagnostic tool in clinical practice, yet existing multimodal large language models (MLLMs) remain unreliable for ECG interpretation, often producing plausible but clinically incorrect analyses. To address this, we propose ECG-R1, the first reasoning ECG MLLM designed for reliable ECG interpretation via three innovations. First, we construct the interpretation corpus using \textit{Protocol-Guided Instruction Data Generation}, grounding interpretation in measurable ECG features and monograph-defined quantitative thresholds and diagnostic logic. Second, we present a modality-decoupled architecture with \textit{Interleaved Modality Dropout} to improve robustness and cross-modal consistency when either the ECG signal or ECG image is missing. Third, we present \textit{Reinforcement Learning with ECG Diagnostic Evidence Rewards} to strengthen evidence-grounded ECG interpretation. Additionally, we systematically evaluate the ECG interpretation capabilities of proprietary, open-source, and medical MLLMs, and provide the first quantitative evidence that severe hallucinations are widespread, suggesting that the public should not directly trust these outputs without independent verification. Code is available at \href{https://github.com/PKUDigitalHealth/ECG-R1}{here}.

cs.CL

A Scoping Review of Deep Learning Methods for Photoplethysmography Data

Background: Photoplethysmography (PPG) is a non-invasive optical sensing technique widely used to capture hemodynamic information, with broad deployment in both clinical monitoring systems and wearable devices. In recent years, the integration of deep learning has substantially advanced PPG signal analysis and expanded its applications across healthcare and non-healthcare domains. Methods: We conducted a comprehensive literature search for studies applying deep learning to PPG data published between January 1, 2017 and December 31, 2025, using Google Scholar, PubMed, and Dimensions. The included studies were analyzed from three key perspectives: tasks, models, and data. Results: A total of 460 papers applying deep learning techniques to PPG signal analysis were included. These studies span a wide range of application domains, from traditional physiological monitoring tasks such as cardiovascular assessment to emerging applications including sleep analysis, cross-modality signal reconstruction, and biometric identification. Conclusions: Deep learning has significantly advanced PPG signal analysis by enabling more effective extraction of physiological information. Compared with traditional machine learning approaches reliant on handcrafted features, deep learning methods generally achieve improved performance and offer greater flexibility in model development. Nevertheless, several challenges remain, including limited availability of large-scale high-quality datasets, insufficient validation in real-world environments, and concerns over model interpretability, scalability, and computational efficiency. Addressing these challenges and exploring emerging research directions will be essential for further progress in deep learning-based PPG analysis.

cs.AI

Masked Training for Robust Arrhythmia Detection from Digitalized Multiple Layout ECG Images

Background: Electrocardiograms are indispensable for diagnosing cardiovascular diseases, yet in many settings they exist only as paper printouts stored in multiple recording layouts. Converting these images into digital signals introduces two key challenges: temporal asynchrony among leads and partial blackout missing, where contiguous signal segments become entirely unavailable. Existing models cannot adequately handle these concurrent problems while maintaining interpretability. Methods: We propose PatchECG, combining an adaptive variable block count missing learning mechanism with a masked training strategy. The model segments each lead into fixed-length patches, discards entirely missing patches, and encodes the remainder via a pluggable patch encoder. A disordered patch attention mechanism with patch-level temporal and lead embeddings captures cross-lead and temporal dependencies without interpolation. PatchECG was trained on PTB-XL and evaluated under seven simulated layout conditions, with external validation on 400 real ECG images from Chaoyang Hospital across three clinical layouts. Results: PatchECG achieves an average AUROC of approximately 0.835 across all simulated layouts. On the Chaoyang cohort, the model attains an overall AUROC of 0.778 for atrial fibrillation detection, rising to 0.893 on the 12x1 subset -- surpassing the pre-trained baseline by 0.111 and 0.190, respectively. Model attention aligns with cardiologist annotations at a rate approaching inter-clinician agreement. Conclusions: PatchECG provides a robust, interpolation-free, and interpretable solution for arrhythmia detection from digitized ECG images across diverse layouts. Its direct modeling of asynchronous and partially missing signals, combined with clinically aligned attention, positions it as a practical tool for cardiac diagnostics from legacy ECG archives in real-world clinical environments.

cs.LG

Artificial intelligence-enabled single-lead ECG for non-invasive hyperkalemia detection: development, multicenter validation, and proof-of-concept deployment

Hyperkalemia is a life-threatening electrolyte disorder that is common in patients with chronic kidney disease and heart failure, yet frequent monitoring remains difficult outside hospital settings. We developed and validated Pocket-K, a single-lead AI-ECG system initialized from the ECGFounder foundation model for non-invasive hyperkalemia screening and handheld deployment. In this multicentre observational study using routinely collected clinical ECG and laboratory data, 34,439 patients contributed 62,290 ECG--potassium pairs. Lead I data were used to fine-tune the model. Data from Peking University People's Hospital were divided into development and temporal validation sets, and data from The Second Hospital of Tianjin Medical University served as an independent external validation set. Hyperkalemia was defined as venous serum potassium > 5.5 mmol/L. Pocket-K achieved AUROCs of 0.936 in internal testing, 0.858 in temporal validation, and 0.808 in external validation. For KDIGO-defined moderate-to-severe hyperkalemia (serum potassium >= 6.0 mmol/L), AUROCs increased to 0.940 and 0.861 in the temporal and external sets, respectively. External negative predictive value exceeded 99.3%. Model-predicted high risk below the hyperkalemia threshold was more common in patients with chronic kidney disease and heart failure. A handheld prototype enabled near-real-time inference, supporting future prospective evaluation in native handheld and wearable settings.

cs.LG

Opportunistic Screening of Wolff-Parkinson-White Syndrome using Single-Lead AI-ECG Mobile System: A Real-World Study of over 3.5 million ECG Recordings in China

Wolff-Parkinson-White (WPW) syndrome, a congenital cardiac conduction abnormality with low prevalence, carries a significant risk of sudden cardiac death. Early identification remains challenging due to screening costs and professional resource scarcity. This retrospective real-world study systematically evaluates an integrated Artificial Intelligence-enabled mobile screening system comprising portable single-lead devices, AI primary screening, and cardiologist review. Analyzing 3,566,626 ECG records from 87,836 individuals between 2019 and 2025, the AI model achieved an AUC of 0.6676 and a specificity of 95.92% in complex real-world signal environments. Despite predictive probability bias inherent in ultra-low prevalence contexts, the model demonstrated stable risk stratification, with high-confidence scores concentrated among true positive individuals. The risk of detecting WPW in AI-positive records was 86.2-fold higher than in AI-negative records. By implementing a human-AI collaborative workflow, the volume of ECGs requiring manual review was reduced by approximately 99.5% compared to universal screening. In an ideal collaborative scenario, an average of only 18 ECGs required review to confirm one WPW case, representing a more than 60-fold increase in screening efficiency. Compared to traditional 12-lead ECGs and electrophysiological studies, this system significantly reduced time and medical costs. Our findings suggest that a risk-stratification-based human-AI collaborative system provides a promising paradigm for the early public health detection of low-prevalence, high-risk arrhythmias.

eess.SP

Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning

Aortic valve disease (AVD) represents a major public health burden, while its diagnosis relies on echocardiography, which is limited by cost and specialist expertise, restricting scalable screening and risk stratification. Existing portable sensing modalities are constrained by indirect representations or acquisition dependencies. In this context, photoplethysmography (PPG), a widely available optical signal capturing peripheral hemodynamic dynamics, provides a scalable physiological measurement. However, the scarcity of clinically labeled PPG data severely constrains the development of effective data-driven models. To address this limitation, we propose Physiology-Guided Self-Supervised Learning (PG-SSL), leveraging approximately 170,000 unlabeled UK Biobank PPG recordings. PG-SSL constructs physiologically derived pseudo-labels based on clinically motivated waveform phenotypes associated with aortic stenosis (AS) and aortic regurgitation (AR), enabling large-scale pretraining without AVD-specific labels. Following fine-tuning on a small labeled cohort, the model achieved AUROCs of 0.8025 for AS and 0.7669 for AR. Further analyses demonstrated robustness under clinical confounding and covariate-balanced evaluation, as well as significant longitudinal associations with incident AVD events. This study demonstrates the feasibility of PG-SSL for leveraging large-scale unlabeled physiological signals under clinically labeled data-scarce conditions. The proposed approach provides a useful strategy for improving low-cost PPG-based screening and risk enrichment for clinically recognized AVD.

eess.SP

ECGomics: An Open Platform for AI-ECG Digital Biomarker Discovery

Background: Conventional electrocardiogram (ECG) analysis faces a persistent dichotomy: expert-driven features ensure interpretability but lack sensitivity to latent patterns, while deep learning offers high accuracy but functions as a black box with high data dependency. We introduce ECGomics, a systematic paradigm and open-source platform for the multidimensional deconstruction of cardiac signals into digital biomarker. Methods: Inspired by the taxonomic rigor of genomics, ECGomics deconstructs cardiac activity across four dimensions: Structural, Intensity, Functional, and Comparative. This taxonomy synergizes expert-defined morphological rules with data-driven latent representations, effectively bridging the gap between handcrafted features and deep learning embeddings. Results: We operationalized this framework into a scalable ecosystem consisting of a web-based research platform and a mobile-integrated solution (https://github.com/PKUDigitalHealth/ECGomics). The web platform facilitates high-throughput analysis via precision parameter configuration, high-fidelity data ingestion, and 12-lead visualization, allowing for the systematic extraction of biomarkers across the four ECGomics dimensions. Complementarily, the mobile interface, integrated with portable sensors and a cloud-based engine, enables real-time signal acquisition and near-instantaneous delivery of structured diagnostic reports. This dual-interface architecture successfully transitions ECGomics from theoretical discovery to decentralized, real-world health management, ensuring professional-grade monitoring in diverse clinical and home-based settings. Conclusion: ECGomics harmonizes diagnostic precision, interpretability, and data efficiency. By providing a deployable software ecosystem, this paradigm establishes a robust foundation for digital biomarker discovery and personalized cardiovascular medicine.

q-bio.QM

AnyECG: Evolved ECG Foundation Model for Holistic Health Profiling

Background: Artificial intelligence enabled electrocardiography (AI-ECG) has demonstrated the ability to detect diverse pathologies, but most existing models focus on single disease identification, neglecting comorbidities and future risk prediction. Although ECGFounder expanded cardiac disease coverage, a holistic health profiling model remains needed. Methods: We constructed a large multicenter dataset comprising 13.3 million ECGs from 2.98 million patients. Using transfer learning, ECGFounder was fine-tuned to develop AnyECG, a foundation model for holistic health profiling. Performance was evaluated using external validation cohorts and a 10-year longitudinal cohort for current diagnosis, future risk prediction, and comorbidity identification. Results: AnyECG demonstrated systemic predictive capability across 1172 conditions, achieving an AUROC greater than 0.7 for 306 diseases. The model revealed novel disease associations, robust comorbidity patterns, and future disease risks. Representative examples included high diagnostic performance for hyperparathyroidism (AUROC 0.941), type 2 diabetes (0.803), Crohn disease (0.817), lymphoid leukemia (0.856), and chronic obstructive pulmonary disease (0.773). Conclusion: The AnyECG foundation model provides substantial evidence that AI-ECG can serve as a systemic tool for concurrent disease detection and long-term risk prediction.

eess.SP

Fine-tuning an ECG Foundation Model to Predict Coronary CT Angiography Outcomes

Coronary artery disease (CAD) remains a major global public health burden, yet scalable pre-imaging risk stratification tools are limited. In this multicenter study, we developed and validated an artificial intelligence-enabled electrocardiography (AI-ECG) model using coronary computed tomographic angiography (CCTA) as the anatomical reference to predict vessel-specific hemodynamically significant stenosis ($\geq 70\%$ for RCA, LAD, LCX; $\geq 50\%$ for LM). The model was evaluated in internal and external cohorts, clinically normal ECGs, and prespecified demographic and clinical subgroups. It showed discrimination across vessels in internal validation and consistent external and normal ECG performance. Predicted probabilities increased with CCTA-defined stenosis severity and were converted into vessel-specific low-, intermediate-, and high-risk strata. Calibration and decision curve analyses supported its clinical utility. Integration with guideline-based pre-test probability improved risk reclassification, enhanced rule-out performance, and reduced the gray-zone proportion. In longitudinal follow-up, model-defined risk groups showed clear separation in major adverse cardiovascular events. Waveform- and attribution-based analyses identified structured ECG differences and physiologically meaningful signal regions linked to high-risk predictions. These results support AI-ECG as a feasible tool for pre-imaging risk stratification and clinical triage, warranting prospective validation in broader clinical settings.

cs.CV

Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure

Right heart failure (RHF) is a disease characterized by abnormalities in the structure or function of the right ventricle (RV), which is associated with high morbidity and mortality. Lung disease often causes increased right ventricular load, leading to RHF. Therefore, it is very important to screen out patients with cor pulmonale who develop RHF from people with underlying lung diseases. In this work, we propose a self-supervised representation learning method to early detecting RHF from patients with cor pulmonale, which uses spirogram time series to predict patients with RHF at an early stage. The proposed model is divided into two stages. The first stage is the self-supervised representation learning-based spirogram embedding (SLSE) network training process, where the encoder of the Variational autoencoder (VAE-encoder) learns a robust low-dimensional representation of the spirogram time series from the data-augmented unlabeled data. Second, this low-dimensional representation is fused with demographic information and fed into a CatBoost classifier for the downstream RHF prediction task. Trained and tested on a carefully selected subset of 26,617 individuals from the UK Biobank, our model achieved an AUROC of 0.7501 in detecting RHF, demonstrating strong population-level distinction ability. We further evaluated the model on high-risk clinical subgroups, achieving AUROC values of 0.8194 on a test set of 74 patients with chronic kidney disease (CKD) and 0.8413 on a set of 64 patients with valvular heart disease (VHD). These results highlight the model's potential utility in predicting RHF among clinically elevated-risk populations. In conclusion, this study presents a self-supervised representation learning approach combining spirogram time series and demographic data, demonstrating promising potential for early RHF detection in clinical practice.

cs.LG

On-device Computation of Single-lead ECG Parameters for Real-time Remote Cardiac Health Assessment: A Real-world Validation Study

Accurate, continuous out-of-hospital electrocardiogram (ECG) parameter measurement is vital for real-time cardiac health monitoring and telemedicine. On-device computation of single-lead ECG parameters enables timely assessment without reliance on centralized data processing, advancing personalized, ubiquitous cardiac care-yet comprehensive validation across heterogeneous real-world populations remains limited. This study validated the on-device algorithm FeatureDB (https://github.com/PKUDigitalHealth/FeatureDB) using two datasets: HeartVoice-ECG-lite (369 participants with single-lead ECGs annotated by two physicians) and PTB-XL/PTB-XL+ (21,354 patients with 12-lead ECGs and physicians' diagnostic annotations). FeatureDB computed PR, QT, and QTc intervals, with accuracy evaluated against physician annotations via mean absolute error (MAE), correlation analysis, and Bland-Altman analysis. Diagnostic performance for first-degree atrioventricular block (AVBI, PR-based) and long QT syndrome (LQT, QTc-based) was benchmarked against commercial 12-lead systems (12SL, Uni-G) and open-source algorithm Deli, using AUC, accuracy, sensitivity, and specificity. Results showed high concordance with expert annotations (Pearson correlations: 0.836-0.960), MAEs matching inter-observer variability, and minimal bias. AVBI AUC reached 0.787 (12SL: 0.859; Uni-G: 0.812; Deli: 0.501); LQT AUC was 0.684 (12SL: 0.716; Uni-G: 0.605; Deli: 0.569)-comparable to commercial tools and superior to open-source alternatives. FeatureDB delivers physician-level parameter accuracy and commercial-grade abnormality detection via single-lead devices, supporting scalable telemedicine, decentralized cardiac screening, and continuous monitoring in community and outpatient settings.

eess.SP

AnyECG-Lab: An Exploration Study of Fine-tuning an ECG Foundation Model to Estimate Laboratory Values from Single-Lead ECG Signals

Timely access to laboratory values is critical for clinical decision-making, yet current approaches rely on invasive venous sampling and are intrinsically delayed. Electrocardiography (ECG), as a non-invasive and widely available signal, offers a promising modality for rapid laboratory estimation. Recent progress in deep learning has enabled the extraction of latent hematological signatures from ECGs. However, existing models are constrained by low signal-to-noise ratios, substantial inter-individual variability, limited data diversity, and suboptimal generalization, especially when adapted to low-lead wearable devices. In this work, we conduct an exploratory study leveraging transfer learning to fine-tune ECGFounder, a large-scale pre-trained ECG foundation model, on the Multimodal Clinical Monitoring in the Emergency Department (MC-MED) dataset from Stanford. We generated a corpus of more than 20 million standardized ten-second ECG segments to enhance sensitivity to subtle biochemical correlates. On internal validation, the model demonstrated strong predictive performance (area under the curve above 0.65) for thirty-three laboratory indicators, moderate performance (between 0.55 and 0.65) for fifty-nine indicators, and limited performance (below 0.55) for sixteen indicators. This study provides an efficient artificial-intelligence driven solution and establishes the feasibility scope for real-time, non-invasive estimation of laboratory values.

cs.LG

Reconstructing 12-Lead ECG from 3-Lead ECG using Variational Autoencoder to Improve Cardiac Disease Detection of Wearable ECG Devices

Twelve-lead electrocardiograms (ECGs) are the clinical gold standard for cardiac diagnosis, providing comprehensive spatial coverage of the heart necessary to detect conditions such as myocardial infarction (MI). However, their lack of portability limits continuous and large-scale use. Three-lead ECG systems are widely used in wearable devices due to their simplicity and mobility, but they often fail to capture pathologies in unmeasured regions. To address this, we propose WearECG, a Variational Autoencoder (VAE) method that reconstructs twelve-lead ECGs from three leads: II, V1, and V5. Our model includes architectural improvements to better capture temporal and spatial dependencies in ECG signals. We evaluate generation quality using MSE, MAE, and Frechet Inception Distance (FID), and assess clinical validity via a Turing test with expert cardiologists. To further validate diagnostic utility, we fine-tune ECGFounder, a large-scale pretrained ECG model, on a multi-label classification task involving over 40 cardiac conditions, including six different myocardial infarction locations, using both real and generated signals. Experiments on the MIMIC dataset show that our method produces physiologically realistic and diagnostically informative signals, with robust performance in downstream tasks. This work demonstrates the potential of generative modeling for ECG reconstruction and its implications for scalable, low-cost cardiac screening.

cs.LG

MEETI: A Multimodal ECG Dataset from MIMIC-IV-ECG with Signals, Images, Features and Interpretations

Electrocardiogram (ECG) plays a foundational role in modern cardiovascular care, enabling non-invasive diagnosis of arrhythmias, myocardial ischemia, and conduction disorders. While machine learning has achieved expert-level performance in ECG interpretation, the development of clinically deployable multimodal AI systems remains constrained, primarily due to the lack of publicly available datasets that simultaneously incorporate raw signals, diagnostic images, and interpretation text. Most existing ECG datasets provide only single-modality data or, at most, dual modalities, making it difficult to build models that can understand and integrate diverse ECG information in real-world settings. To address this gap, we introduce MEETI (MIMIC-IV-Ext ECG-Text-Image), the first large-scale ECG dataset that synchronizes raw waveform data, high-resolution plotted images, and detailed textual interpretations generated by large language models. In addition, MEETI includes beat-level quantitative ECG parameters extracted from each lead, offering structured parameters that support fine-grained analysis and model interpretability. Each MEETI record is aligned across four components: (1) the raw ECG waveform, (2) the corresponding plotted image, (3) extracted feature parameters, and (4) detailed interpretation text. This alignment is achieved using consistent, unique identifiers. This unified structure supports transformer-based multimodal learning and supports fine-grained, interpretable reasoning about cardiac health. By bridging the gap between traditional signal analysis, image-based interpretation, and language-driven understanding, MEETI established a robust foundation for the next generation of explainable, multimodal cardiovascular AI. It offers the research community a comprehensive benchmark for developing and evaluating ECG-based AI systems.

eess.SP

DiffuSETS: 12-lead ECG Generation Conditioned on Clinical Text Reports and Patient-Specific Information

Heart disease remains a significant threat to human health. As a non-invasive diagnostic tool, the electrocardiogram (ECG) is one of the most widely used methods for cardiac screening. However, the scarcity of high-quality ECG data, driven by privacy concerns and limited medical resources, creates a pressing need for effective ECG signal generation. Existing approaches for generating ECG signals typically rely on small training datasets, lack comprehensive evaluation frameworks, and overlook potential applications beyond data augmentation. To address these challenges, we propose DiffuSETS, a novel framework capable of generating ECG signals with high semantic alignment and fidelity. DiffuSETS accepts various modalities of clinical text reports and patient-specific information as inputs, enabling the creation of clinically meaningful ECG signals. Additionally, to address the lack of standardized evaluation in ECG generation, we introduce a comprehensive benchmarking methodology to assess the effectiveness of generative models in this domain. Our model achieve excellent results in tests, proving its superiority in the task of ECG generation. Furthermore, we showcase its potential to mitigate data scarcity while exploring novel applications in cardiology education and medical knowledge discovery, highlighting the broader impact of our work.

cs.LG

Artificial Intelligence System for Detection and Screening of Cardiac Abnormalities using Electrocardiogram Images

The artificial intelligence (AI) system has achieved expert-level performance in electrocardiogram (ECG) signal analysis. However, in underdeveloped countries or regions where the healthcare information system is imperfect, only paper ECGs can be provided. Analysis of real-world ECG images (photos or scans of paper ECGs) remains challenging due to complex environments or interference. In this study, we present an AI system developed to detect and screen cardiac abnormalities (CAs) from real-world ECG images. The system was evaluated on a large dataset of 52,357 patients from multiple regions and populations across the world. On the detection task, the AI system obtained area under the receiver operating curve (AUC) of 0.996 (hold-out test), 0.994 (external test 1), 0.984 (external test 2), and 0.979 (external test 3), respectively. Meanwhile, the detection results of AI system showed a strong correlation with the diagnosis of cardiologists (cardiologist 1 (R=0.794, p<1e-3), cardiologist 2 (R=0.812, p<1e-3)). On the screening task, the AI system achieved AUCs of 0.894 (hold-out test) and 0.850 (external test). The screening performance of the AI system was better than that of the cardiologists (AI system (0.846) vs. cardiologist 1 (0.520) vs. cardiologist 2 (0.480)). Our study demonstrates the feasibility of an accurate, objective, easy-to-use, fast, and low-cost AI system for CA detection and screening. The system has the potential to be used by healthcare professionals, caregivers, and general users to assess CAs based on real-world ECG images.

cs.CV