Fast Alternating Radial Beamforming for Speed-of-Sound Imaging Based on Apparent Speckle Shifts

Pulse-echo speed-of-sound (SoS) imaging based on minute misalignments between consecutively acquired ultrasound images traditionally relies on images beamformed on Cartesian grids. Existing SoS imaging developments do not allow for real-time imaging and typically do not prioritize feasibility in conventional ultrasound systems that have limited resources and rigid processing structures. In this work, we propose a resource-efficient approach based on radial beamforming with virtual source transmits for implementation within an on-the-fly beamformer. We also introduce alternating transmissions with fast pair-alternating beamforming for motion-robust displacement tracking with typical line-based beamformers. We tested these methods comparatively on numerical simulations, tissue-mimicking phantom experiments, and in vivo data from breast lesion examinations. We demonstrate that the proposed radial grid beamforming approach performs comparably to a Cartesian grid approach, while allowing implementation on standard hardware for beamforming. Our proposed sequences would allow for SoS data acquisition frame rates of more than 20 fps in parallel to conventional B-mode imaging. The proposed speckle-shift based radial approach with fast alternation between congruent beamforming lines is a major step towards real-time SoS imaging on standard ultrasound systems with moderate resources.

eess.IV

Uncertainty Estimation for Trust Attribution to Speed-of-Sound Reconstruction with Variational Networks

Speed-of-sound (SoS) is a biomechanical characteristic of tissue, and its imaging can provide a promising biomarker for diagnosis. Reconstructing SoS images from ultrasound acquisitions can be cast as a limited-angle computed-tomography problem, with Variational Networks being a promising model-based deep learning solution. Some acquired data frames may, however, get corrupted by noise due to, e.g., motion, lack of contact, and acoustic shadows, which in turn negatively affects the resulting SoS reconstructions. We propose to use the uncertainty in SoS reconstructions to attribute trust to each individual acquired frame. Given multiple acquisitions, we then use an uncertainty based automatic selection among these retrospectively, to improve diagnostic decisions. We investigate uncertainty estimation based on Monte Carlo Dropout and Bayesian Variational Inference. We assess our automatic frame selection method for differential diagnosis of breast cancer, distinguishing between benign fibroadenoma and malignant carcinoma. We evaluate 21 lesions classified as BI-RADS~4, which represents suspicious cases for probable malignancy. The most trustworthy frame among four acquisitions of each lesion was identified using uncertainty based criteria. Selecting a frame informed by uncertainty achieved an area under curve of 76% and 80% for Monte Carlo Dropout and Bayesian Variational Inference, respectively, superior to any uncertainty-uninformed baselines with the best one achieving 64%. A novel use of uncertainty estimation is proposed for selecting one of multiple data acquisitions for further processing and decision making.

cs.CV

Robust Imaging of Speed-of-Sound Using Virtual Source Transmission

Speed-of-sound (SoS) is a novel imaging biomarker for assessing biomechanical characteristics of soft tissues. SoS imaging in pulse-echo mode using conventional ultrasound systems with hand-held transducers has the potential to enable new clinical uses. Recent work demonstrated diverging waves from single-element (SE) transmits to outperform plane-wave sequences. However, single-element transmits have severely limited power and hence produce low signal-to-noise ratio (SNR) in echo data. We herein propose Walsh-Hadamard (WH) coded and virtual-source (VS) transmit sequences for improved SNR in SoS imaging. We additionally present an iterative method of estimating beamforming SoS in the medium, which otherwise confound SoS reconstructions due to beamforming inaccuracies in the images used for reconstruction. Through numerical simulations, phantom experiments, and in-vivo imaging data, we show that WH is not robust against motion, which is often unavoidable in clinical imaging scenarios. Our proposed virtual-source sequence is shown to provide the highest SoS reconstruction performance, especially robust to motion artifacts. In phantom experiments, despite having a comparable SoS root-mean-square-error (RMSE) of 17.5 to 18.0 m/s at rest, with a minor axial probe motion of ~0.67 mm/s the RMSE for SE, WH, and VS already deteriorate to 20.2, 105.4, 19.0 m/s, respectively; showing that WH produces unacceptable results, not robust to motion. In the clinical data, the high SNR and motion-resilience of VS sequence is seen to yield superior contrast compared to SE and WH sequences.

physics.med-ph

Frequency-Dependent Attenuation Reconstruction with an Acoustic Reflector

Attenuation of ultrasound waves varies with tissue composition, hence its estimation offers great potential for tissue characterization and diagnosis and staging of pathology. We recently proposed a method that allows to spatially reconstruct the distribution of the overall ultrasound attenuation in tissue based on computed tomography, using reflections from a passive acoustic reflector. This requires a standard ultrasound transducer operating in pulse-echo mode and a calibration protocol using water measurements, thus it can be implemented on conventional ultrasound systems with minor adaptations. Herein, we extend this method by additionally estimating and imaging the frequency-dependent nature of local ultrasound attenuation for the first time. Spatial distributions of attenuation coefficient and exponent are reconstructed, enabling an elaborate and expressive tissue-specific characterization. With simulations, we demonstrate that our proposed method yields a low reconstruction error of 0.04dB/cm at 1MHz for attenuation coefficient and 0.08 for the frequency exponent. With tissue-mimicking phantoms and ex-vivo bovine muscle samples, a high reconstruction contrast as well as reproducibility are demonstrated. Attenuation exponents of a gelatin-cellulose mixture and an ex-vivo bovine muscle sample were found to be, respectively, 1.4 and 0.5 on average, consistently from different images of their heterogeneous compositions. Such frequency-dependent parametrization could enable novel imaging and diagnostic techniques, as well as facilitate attenuation compensation of other ultrasound-based imaging techniques.

physics.med-ph

Speed-of-Sound Imaging using Diverging Waves

Recent ultrasound imaging modalities based on ultrasound computed tomography indicate a huge potential to detect pathologies is tissue due to altered biomechanical properties. Especially the imaging of speed-of-sound (SoS) distribution in tissue has shown clinical promise and thus gained increasing attention in the field -- with several methods proposed based on transmission mode tomography. SoS imaging using conventional ultrasound (US) systems would be convenient and easy for clinical translation, but this requires using conventional US probes with single-sides tissue access and thus pulse-echo imaging sequences. Recent pulse-echo SoS imaging methods rely on plane wave (PW) insonifications, which is prone to strong aberration effects for non-homogeneous tissue composition. In this paper we propose to use diverging waves (DW) for SoS imaging and thus substantially improve the reconstruction of SoS distributions. We study this proposition by first plane wavefront aberrations compared to DW. We then present the sensitivity of both approaches to major parameterization choices on a set of simulated phantoms. Using the optimum parameter combination for each method for a given transducer model and imaging sequence, we analyze the SoS imaging performance comparatively between the two approaches. Results indicate that using DW instead of PW, the reconstruction accuracy improves substantially, by over 22% in reconstruction error (RMSE) and by 55% in contrast (CNR). We also demonstrate improvements in SoS reconstructions from an actual US acquisition of a breast phantom with tumor- and cyst-representative inclusions, with high and low SoS contrast, respectively.

physics.med-ph

Ultrasound Aberration Correction based on Local Speed-of-Sound Map Estimation

For beamforming ultrasound (US) signals, typically a spatially constant speed-of-sound (SoS) is assumed to calculate delays. As SoS in tissue may vary relatively largely, this approximation may cause wavefront aberrations, thus degrading effective imaging resolution. In the literature, corrections have been proposed based on unidirectional SoS estimation or computationally-expensive a posteriori phase rectification. In this paper we demonstrate a direct delay correction approach for US beamforming, by leveraging 2D spatial SoS distribution estimates from plane-wave imaging. We show both in simulations and with ex vivo measurements that resolutions close to the wavelength limit can be achieved using our proposed local SoS-adaptive beamforming, yielding a lateral resolution improvement of 22% to 29% on tissue samples with up to 3% SoS-contrast (45m/s). We verify that our method accurately images absolute positions of tissue structures down to sub-pixel resolution of a tenth of a wavelength, whereas a global SoS assumption leads to artifactual localizations.

eess.IV

Attenuation Imaging with Pulse-Echo Ultrasound based on an Acoustic Reflector

Ultrasound attenuation is caused by absorption and scattering in tissue and is thus a function of tissue composition, hence its imaging offers great potential for screening and differential diagnosis. In this paper we propose a novel method that allows to reconstruct spatial attenuation distribution in tissue based on computed tomography, using reflections from a passive acoustic reflector. This requires a standard ultrasound transducer operating in pulse-echo mode, thus it can be implemented on conventional ultrasound systems with minor modifications. We use calibration with water measurements in order to normalize measurements for quantitative imaging of attenuation. In contrast to earlier techniques, we herein show that attenuation reconstructions are possible without any geometric prior on the inclusion location or shape. We present a quantitative evaluation of reconstructions based on simulations, gelatin phantoms, and ex-vivo bovine skeletal muscle tissue, achieving contrast-to-noise ratio of up to 2.3 for an inclusion in ex-vivo tissue.

eess.SP