SearcharxivSearch

arXiv subjects

Dixiao Lu

Publications and source records attributed to Dixiao Lu.

2 recordsLinked to original sources

Performance and pulse shape discrimination of glass scintillator SG101 for neutron detection

We present a detailed characterization of the thermal neutron sensitive transparent glass scintillator SG101, benchmarked against the conventional LiF ZnS(Ag)based scintillator EJ426. The detection efficiency, energy resolution, and pulse shape discrimination (PSD) performance ofSG101 were evaluated under AmBe neutron irradiation. When coupled with organic scintillators(EJ200 or EJ276),the SG101 EJ200 system achieves a figure of merit (FOM) of 3.81 for thermal neutron/gamma separation, while the SG101 EJ276 configuration resolves three distinct particle populations gamma rays, fast neutrons, and thermal neutrons with FOM values of 3.46 and2.21, respectively. Correlation analysis reveals that the number of fast thermal neutron coincidence events significantly exceeds the accidental background, and the count of gamma fast thermal neutron triple-coincidence events is also far higher than the expected accidental rate, confirming significant physical correlations for both event types within a 100 us time window. These results demonstrate that SG101 is a promising candidate for applications requiring high-efficiency thermal neutron detection and precise event tagging coupling with a scintillator with PSD approach

physics.ins-det

Performance Characterization of a Plastic-Scintillator Sensor for Fast-Neutron, Thermal-Neutron, and Gamma-Ray Discrimination

Discrimination of fast neutrons, thermal neutrons, and $\gamma$ rays in mixed radiation fields is important for radiation monitoring, reactor-related measurements, and background suppression in nuclear experiments. In this work, we investigate a compact plastic-scintillator sensor composed of EJ276 or EJ200 optically coupled to an EJ426 thermal neutron screen and read out by a single photomultiplier tube (PMT). The $\gamma$ equivalent energy response of the detector assemblies was calibrated using $^{137}$Cs, $^{22}$Na, and $^{60}$Co sources through Compton edge analysis, and pulse shape discrimination was evaluated with an AmBe neutron source under different moderator thicknesses. The EJ200+EJ426 assembly provides a well separated discrimination between thermal-neutron capture events and $\gamma$ dominated events over the measured range, with a figure of merit greater than 5. In contrast, the EJ276+EJ426 assembly produced three identifiable signal populations associated with $\gamma$ rays, fast neutrons, and thermal neutrons. These results show that the proposed sensor architecture is a promising compact approach for mixed field radiation applications

physics.ins-det