SearcharxivSearch

arXiv subjects

Dmitry S. Novikov

Publications and source records attributed to Dmitry S. Novikov.

At least 19 recordsLinked to original sources

Dependence of the extra-cellular diffusion coefficient on the fractions of neurites and cell bodies in gray matter

Purpose: The dependence of the long-time (tortuosity) limit of the extra-cellular diffusivity on the intra-cellular volume fraction is of fundamental importance for microstructure modeling. While such dependencies have been explored for the white matter, the tortuosity limit in gray matter is unknown due to complex cell composition and geometry. Here we rationalize and validate numerically the analytical relation between the extra-cellular diffusivity and intra-cellular fractions of cell bodies (somas) and neurites. Methods: The tortuosity relation for extra-cellular diffusivity qualitatively follows from effective medium theory, coarse-grained by diffusion outside somas (spheres) and neurites (cylinders), respectively. This problem is equivalent to finding the overall conductivity in a medium of grains in a matrix, with methodology dating back to the 19th century. We extend the effective medium methodology to populations of impermeable spheres and randomly oriented cylinders with various volume fractions, yielding closed-form expressions corroborated by Monte Carlo simulations. Results: We establish the power-law scaling of the extra-cellular diffusivity with the volume fractions of the extra-soma and extra-neurite spaces. We further evaluate the proposed framework using simulations in realistic tissue geometries. Conclusion: Theory and simulations relate extra-cellular tortuosity to soma and neurite fractions, potentially offering a diffusion MRI protocol design optimized for in vivo assessment of soma size and soma/neurite fractions within clinical scan times. Such in vivo measurements can be used to study development, aging and neurodegenerative disorders.

physics.bio-ph

Geometry of the cumulant series in diffusion MRI

Water diffusion gives rise to micron-scale sensitivity of diffusion MRI (dMRI) to cellular-level tissue structure. Precision medicine and quantitative imaging depend on uncovering the information content of dMRI and establishing its parsimonious hardware-independent fingerprint. Based on the rotational SO(3) symmetry, we study the geometry of the dMRI signal and the topology of its acquisition, identify irreducible components and a full set of invariants for the cumulant tensors, and relate them to tissue properties. Including all kurtosis invariants improves multiple sclerosis classification in a cohort of 1189 subjects. We design the shortest acquisitions based on icosahedral vertices to determine the most used invariants in only 1-2 minutes for whole brain. Representing dMRI via scalar invariant maps with definite symmetries will underpin machine learning classifiers of pathology, development, and aging, while fast protocols will enable translation of advanced dMRI into clinic.

physics.med-ph

What if each voxel were measured with a different diffusion protocol?

Expansion of diffusion MRI (dMRI) both into the realm of strong gradients, and into accessible imaging with portable low-field devices, brings about the challenge of gradient nonlinearities. Spatial variations of the diffusion gradients make diffusion weightings and directions non-uniform across the field of view, and deform perfect shells in the q-space designed for isotropic directional coverage. Such imperfections hinder parameter estimation: Anisotropic shells hamper the deconvolution of fiber orientation distribution function (fODF), while brute-force retraining of a nonlinear regressor for each unique set of directions and diffusion weightings is computationally inefficient. Here we propose a protocol-independent parameter estimation (PIPE) method that enables fast parameter estimation for the most general case where the scan in each voxel is acquired with a different protocol in q-space. PIPE applies for any spherical convolution-based dMRI model, irrespective of its complexity, which makes it suitable both for white and gray matter in the brain or spinal cord, and for other tissues where fiber bundles have the same properties within a voxel (fiber response), but are distributed with an arbitrary fODF. Applied to in vivo human MRI with linear tensor encoding on a high-performance system, PIPE maps fiber response and fODF parameters for the whole brain in the presence of significant gradient nonlinearities in under 3 minutes. PIPE enables fast parameter estimation in the presence of arbitrary gradient nonlinearities, eliminating the need to arrange dMRI in shells or to retrain the estimator for different protocols in each voxel. PIPE applies for any model based on a convolution of a voxel-wise fiber response and fODF, and data from varying b-values, diffusion/echo times, and other scan parameters.

physics.med-ph

Scattering approach to diffusion quantifies axonal damage in brain injury

Early diagnosis and noninvasive monitoring of neurological disorders require sensitivity to elusive cellular-level alterations that occur much earlier than volumetric changes observable with the millimeter-resolution of medical imaging modalities. Morphological changes in axons, such as axonal varicosities or beadings, are observed in neurological disorders, as well as in development and aging. Here, we reveal the sensitivity of time-dependent diffusion MRI (dMRI) to the structurally disordered axonal morphology at the micrometer scale. Scattering theory uncovers the two parameters that determine the diffusive dynamics of water along axons: the average reciprocal cross-section and the variance of long-range cross-sectional fluctuations. This theoretical development allows us to predict dMRI metrics sensitive to axonal alterations over tens of thousands of axons in seconds rather than months of simulations in a rat model of traumatic brain injury, and is corroborated with ex vivo dMRI. Our approach bridges the gap between micrometers and millimeters in resolution, offering quantitative and objective biomarkers applicable to a broad spectrum of neurological disorders.

physics.med-ph

Denoising Improves Cross-Scanner and Cross-Protocol Test-Retest Reproducibility of Higher-Order Diffusion Metrics

The clinical translation of diffusion MRI (dMRI)-derived quantitative contrasts hinges on robust reproducibility, minimizing both same-scanner and cross-scanner variability. This study evaluates the reproducibility of higher-order diffusion metrics (beyond conventional diffusion tensor imaging), at the voxel and region-of-interest levels on magnitude and complex-valued dMRI data, using denoising with and without harmonization. We compared same-scanner, cross-scanner, and cross-protocol variability for a multi-shell dMRI protocol in 20 subjects. We first evaluated the effectiveness of denoising strategies for both magnitude and complex data to mitigate noise-induced bias and variance, to improve dMRI parametric maps and reproducibility. We examined the impact of denoising under different analysis approaches, comparing voxel-wise and region of interest (ROI)-based methods. We also evaluated the role of denoising when harmonizing dMRI across scanners and protocols. DTI and DKI maps visually improve after MPPCA denoising, with noticeably fewer outliers in kurtosis maps. Denoising enhances voxel-wise reproducibility, with test-retest variability of kurtosis indices reduced from 15-20% to 5-10% after denoising. Complex dMRI denoising reduces the noise floor by up to 60%. In ROI-analyses, denoising also increased statistical power, with reduction in sample size requirements by up to 40% for detecting differences across populations. Combining denoising with linear-RISH harmonization, in voxel-wise assessments, improved intra-scanner intraclass correlation coefficients for FA from moderate to excellent repeatability over harmonization alone. The enhancement in data quality and precision due to denoising facilitates the broader application and acceptance of these advanced imaging techniques in both clinical practice and large-scale neuroimaging studies.

physics.med-ph

Optimization and Validation of the DESIGNER dMRI preprocessing pipeline in white matter aging

Various diffusion MRI (dMRI) preprocessing pipelines are currently available to yield more accurate diffusion parameters. Here, we evaluated accuracy and robustness of the optimized Diffusion parameter EStImation with Gibbs and NoisE Removal (DESIGNER) pipeline in a large clinical dMRI dataset and using ground truth phantoms. DESIGNER has been modified to improve denoising and target Gibbs ringing for partial Fourier acquisitions. We compared the revisited DESIGNER (Dv2) (including denoising, Gibbs removal, correction for motion, EPI distortion, and eddy currents) against the original DESIGNER (Dv1) pipeline, minimal preprocessing (including correction for motion, EPI distortion, and eddy currents only), and no preprocessing on a large clinical dMRI dataset of 524 control subjects with ages between 25 and 75 years old. We evaluated the effect of specific processing steps on age correlations in white matter with DTI and DKI metrics. We also evaluated the added effect of minimal Gaussian smoothing to deal with noise and to reduce outliers in parameter maps compared to DESIGNER (Dv2)'s noise removal method. Moreover, DESIGNER (Dv2)'s updated noise and Gibbs removal methods were assessed using ground truth dMRI phantom to evaluate accuracy. Results show age correlation in white matter with DTI and DKI metrics were affected by the preprocessing pipeline, causing systematic differences in absolute parameter values and loss or gain of statistical significance. Both in clinical dMRI and ground truth phantoms, DESIGNER (Dv2) pipeline resulted in the smallest number of outlier voxels and improved accuracy in DTI and DKI metrics as noise was reduced and Gibbs removal was improved. Thus, DESIGNER (Dv2) provides more accurate and robust DTI and DKI parameter maps as compared to no preprocessing or minimal preprocessing.

physics.med-ph

Assessment of Precision and Accuracy of Brain White Matter Microstructure using Combined Diffusion MRI and Relaxometry

Joint modeling of diffusion and relaxation has seen growing interest due to its potential to provide complementary information about tissue microstructure. For brain white matter, we designed an optimal diffusion-relaxometry MRI protocol that samples multiple b-values, B-tensor shapes, and echo times (TE). This variable-TE protocol (27 min) has as subsets a fixed-TE protocol (15 min) and a 2-shell dMRI protocol (7 min), both characterizing diffusion only. We assessed the sensitivity, specificity and reproducibility of these protocols with synthetic experiments and in six healthy volunteers. Compared with the fixed-TE protocol, the variable-TE protocol enables estimation of free water fractions while also capturing compartmental $T_2$ relaxation times. Jointly measuring diffusion and relaxation offers increased sensitivity and specificity to microstructure parameters in brain white matter with voxelwise coefficients of variation below 10%.

physics.med-ph

Volume electron microscopy in injured rat brain validates white matter microstructure metrics from diffusion MRI

Biophysical modeling of diffusion MRI (dMRI) offers the exciting potential of bridging the gap between the macroscopic MRI resolution and microscopic cellular features, effectively turning the MRI scanner into a noninvasive in vivo microscope. In brain white matter, the Standard Model (SM) interprets the dMRI signal in terms of axon dispersion, intra- and extra-axonal water fractions and diffusivities. However, for SM to be fully applicable and correctly interpreted, it needs to be carefully evaluated using histology. Here, we perform a comprehensive histological validation of the SM parameters, by characterizing WM microstructure in sham and injured rat brains using volume (3d) electron microscopy (EM) and ex vivo dMRI. Sensitivity is evaluated by how close each SM metric is to its histological counterpart, and specificity by how independent it is from other, non-corresponding histological features. This comparison reveals that SM is sensitive and specific to microscopic properties, clearing the way for the clinical adoption of in vivo dMRI derived SM parameters as biomarkers for neurological disorders.

physics.bio-ph

Mapping tissue microstructure of brain white matter in vivo in health and disease using diffusion MRI

Diffusion magnetic resonance imaging offers unique in vivo sensitivity to tissue microstructure in brain white matter, which undergoes significant changes during development and is compromised in virtually every neurological disorder. Yet, the challenge is to develop biomarkers that are specific to micrometer-scale cellular features in a human MRI scan of a few minutes. Here we quantify the sensitivity and specificity of a multicompartment diffusion modeling framework to the density, orientation and integrity of axons. We demonstrate that using a machine learning based estimator, our biophysical model captures the morphological changes of axons in early development, acute ischemia and multiple sclerosis (total N=821). The methodology of microstructure mapping is widely applicable in clinical settings and in large imaging consortium data to study development, aging and pathology.

physics.med-ph

Reproducibility of the Standard Model of diffusion in white matter on clinical MRI systems

Estimating intra- and extra-axonal microstructure parameters, such as volume fractions and diffusivities, has been one of the major efforts in brain microstructure imaging with MRI. The Standard Model (SM) of diffusion in white matter has unified various modeling approaches based on impermeable narrow cylinders embedded in locally anisotropic extra-axonal space. However, estimating the SM parameters from a set of conventional diffusion MRI (dMRI) measurements is ill-conditioned. Multidimensional dMRI helps resolve the estimation degeneracies, but there remains a need for clinically feasible acquisitions that yield robust parameter maps. Here we find optimal multidimensional protocols by minimizing the mean-squared error of machine learning-based SM parameter estimates for two 3T scanners with corresponding gradient strengths of $40$ and $80\,\unit{mT/m}$. We assess intra-scanner and inter-scanner repeatability for 15-minute optimal protocols by scanning 20 healthy volunteers twice on both scanners. The coefficients of variation all SM parameters except free water fraction are $\lesssim 10\%$ voxelwise and $1-4 \%$ for their region-averaged values. As the achieved SM reproducibility outcomes are similar to those of conventional diffusion tensor imaging, our results enable robust in vivo mapping of white matter microstructure in neuroscience research and in the clinic.

physics.bio-ph

Neurite Exchange Imaging (NEXI): A minimal model of diffusion in gray matter with inter-compartment water exchange

Biophysical models of diffusion in white matter are based on what is now commonly referred to as the "Standard Model" (SM) of non-exchanging anisotropic Gaussian compartments. In this work, we focus on diffusion MRI in gray matter, which requires rethinking basic microstructure modeling blocks. In particular, at least three contributions beyond the SM need to be considered: water exchange across the cell membrane - between neurites and the extracellular space; non-Gaussian diffusion along neuronal and glial processes - resulting from structural disorder; and signal contribution from soma. For the first contribution, we propose Neurite Exchange Imaging (NEXI) as an extension of the SM of diffusion, which builds on the anisotropic Kärger model of two exchanging compartments. Using datasets acquired at multiple diffusion weightings (b) and diffusion times (t) in the rat brain in vivo, we show that for the investigated diffusion time window (~10-45 ms) there is minimal diffusivity time-dependence and more pronounced kurtosis decay with time in gray matter, which is well fit by the exchange model. Moreover, we observe lower signal for longer diffusion times at high b. In light of these observations, we identify exchange as the mechanism that best explains these signal signatures in both low-b and high-b regime, and thereby propose NEXI as the minimal model for gray matter microstructure mapping. We finally highlight multi-b multi-t acquisitions protocols as being best suited to estimate NEXI model parameters reliably. Using this approach, we estimate the inter-compartment water exchange time to be 15 - 60 ms in the rat cortex and hippocampus in vivo, which is of the same order or shorter than the diffusion time in typical diffusion MRI acquisitions. This suggests water exchange as an essential component for interpreting diffusion MRI measurements in gray matter.

physics.med-ph

The impact of realistic axonal shape on axon diameter estimation using diffusion MRI

To study axonal microstructure with diffusion MRI, axons are typically modeled as straight impermeable cylinders, whereby the transverse diffusion MRI signal can be made sensitive to the cylinder's inner diameter. However, the shape of a real axon varies along the axon direction, which couples the longitudinal and transverse diffusion of the overall axon direction. Here we develop a theory of the intra-axonal diffusion MRI signal based on coarse-graining of the axonal shape by 3d diffusion. We demonstrate how the estimate of the inner diameter is confounded by the diameter variations (beading), and by the local variations in direction (undulations) along the axon. We analytically relate diffusion MRI metrics, such as time-dependent radial diffusivity D(t) and kurtosis K(t), to the axonal shape, and validate our theory using Monte Carlo simulations in synthetic undulating axons with randomly positioned beads, and in realistic axons reconstructed from electron microscopy images of mouse brain white matter. We show that (i) In the narrow pulse limit, the inner diameter from D(t) is overestimated by about twofold due to a combination of axon caliber variations and undulations (each contributing a comparable effect size); (ii) The narrow-pulse kurtosis K$_{t\to\infty}$ deviates from that in an ideal cylinder due to caliber variations; we also numerically calculate the fourth-order cumulant for an ideal cylinder in the wide pulse limit, which is relevant for inner diameter overestimation; (iii) In the wide pulse limit, the axon diameter overestimation is mainly due to undulations at low diffusion weightings b; and (iv) The effect of undulations can be considerably reduced by directional averaging of high-b signals, with the apparent inner diameter given by a combination of the axon caliber (dominated by the thickest axons), caliber variations, and the residual contribution of undulations.

physics.med-ph

In vivo observation and biophysical interpretation of time-dependent diffusion in human cortical gray matter

The dependence of the diffusion MRI signal on the diffusion time $t$ is a hallmark of tissue microstructure at the scale of the diffusion length. Here we measure the time-dependence of the mean diffusivity $D(t)$ and mean kurtosis $K(t)$ in cortical gray matter and in 25 gray matter sub-regions, in 10 healthy subjects. Significant diffusivity and kurtosis time-dependence is observed for $t=21.2$-100 ms, and is characterized by a power-law tail $\sim t^{-\vartheta}$ with dynamical exponent $\vartheta$. To interpret our measurements, we systematize the relevant scenarios and mechanisms for diffusion time-dependence in the brain. Using effective medium theory formalisms, we derive an exact relation between the power-law tails in $D(t)$ and $K(t)$. The estimated power-law dynamical exponent $\vartheta\simeq1/2$ in both $D(t)$ and $K(t)$ is consistent with one-dimensional diffusion in the presence of randomly positioned restrictions along neurites. We analyze the short-range disordered statistics of synapses on axon collaterals in the cortex, and perform one-dimensional Monte Carlo simulations of diffusion restricted by permeable barriers with a similar randomness in their placement, to confirm the $\vartheta=1/2$ exponent. In contrast, the Kärger model of exchange is less consistent with the data since it does not capture the diffusivity time-dependence, and the estimated exchange time from $K(t)$ falls below our measured $t$-range. Although we cannot exclude exchange as a contributing factor, we argue that structural disorder along neurites is mainly responsible for the observed time-dependence of diffusivity and kurtosis. Our observation and theoretical interpretation of the $t^{-1/2}$ tail in $D(t)$ and $K(t)$ alltogether establish the sensitivity of a macroscopic MRI signal to micrometer-scale structural heterogeneities along neurites in human gray matter in vivo.

physics.med-ph

A time-dependent diffusion MRI signature of axon caliber variations and beading

MRI provides a unique non-invasive window into the brain, yet is limited to millimeter resolution, orders of magnitude coarser than cell dimensions. Here we show that diffusion MRI is sensitive to the micrometer-scale variations in axon caliber or pathological beading, by identifying a signature power-law diffusion time-dependence of the along-fiber diffusion coefficient. We observe this signature in human brain white matter, and uncover its origins by Monte Carlo simulations in realistic substrates from 3d electron microscopy of mouse corpus callosum. Simulations reveal that the time-dependence originates from axon caliber variation, rather than from mitochondria or axonal undulations. We report a decreased amplitude of time-dependence in multiple sclerosis lesions, illustrating the sensitivity of our method to axonal beading in a plethora of neurodegenerative disorders. This specificity to microstructure offers an exciting possibility of bridging across scales to image cellular-level pathology with a clinically feasible MRI technique.

physics.med-ph

Training a Neural Network for Gibbs and Noise Removal in Diffusion MRI

We develop and evaluate a neural network-based method for Gibbs artifact and noise removal. A convolutional neural network (CNN) was designed for artifact removal in diffusion-weighted imaging data. Two implementations were considered: one for magnitude images and one for complex images. Both models were based on the same encoder-decoder structure and were trained by simulating MRI acquisitions on synthetic non-MRI images. Both machine learning methods were able to mitigate artifacts in diffusion-weighted images and diffusion parameter maps. The CNN for complex images was also able to reduce artifacts in partial Fourier acquisitions. The proposed CNNs extend the ability of artifact correction in diffusion MRI. The machine learning method described here can be applied on each imaging slice independently, allowing it to be used flexibly in clinical applications.

eess.IV

Observation of magnetic structural universality using transverse NMR relaxation

Transverse NMR relaxation from spins diffusing through a random magnetic medium is sensitive to its structure on a mesoscopic scale. In particular, this results in the time-dependent relaxation rate. We show analytically and numerically that this rate approaches the long-time limit in a power-law fashion, with the exponent reflecting the disorder class of mesoscopic magnetic structure. The spectral line shape acquires a corresponding non-analytic power law singularity at zero frequency. We experimentally detect a change in the dynamical exponent as a result of the transition into a maximally random jammed state characterized by hyperuniform correlations.

cond-mat.soft

The Optimality Principle for MR signal excitation and reception: New physical insights into ideal radiofrequency coil design

Purpose: Despite decades of collective experience, radiofrequency coil optimization for MR has remained a largely empirical process, with clear insight into what might constitute truly task-optimal, as opposed to merely 'good,' coil performance being difficult to come by. Here, a new principle, the Optimality Principle, is introduced, which allows one to predict, rapidly and intuitively, the form of optimal current patterns on any surface surrounding any arbitrary body. Theory: The Optimality Principle, in its simplest form, states that the surface current pattern associated with optimal transmit field or receive sensitivity at a point of interest (per unit current integrated over the surface) is a precise scaled replica of the tangential electric field pattern that would be generated on the surface by a precessing spin placed at that point. A more general perturbative formulation enables efficient calculation of the pattern modifications required to optimize signal-to-noise ratio in body-noise-dominated situations. Methods and Results: The unperturbed principle is validated numerically, and convergence of the perturbative formulation is explored in simple geometries. Current patterns and corresponding field patterns in a variety of concrete cases are then used to separate signal and noise effects in coil optimization, to understand the emergence of electric dipoles as strong performers at high frequency, and to highlight the importance of surface geometry in coil design. Conclusion: Like the Principle of Reciprocity from which it is derived, the Optimality Principle offers both a conceptual and a computational shortcut. In addition to providing quantitative targets for coil design, the Optimality Principle affords direct physical insight into the fundamental determinants of coil performance.

physics.ins-det

Hybrid-State Free Precession in Nuclear Magnetic Resonance

The dynamics of large spin-1/2 ensembles in the presence of a varying magnetic field are commonly described by the Bloch equation. Most magnetic field variations result in unintuitive spin dynamics, which are sensitive to small deviations in the driving field. Although simplistic field variations can produce robust dynamics, the captured information content is impoverished. Here, we identify adiabaticity conditions that span a rich experiment design space with tractable dynamics. These adiabaticity conditions trap the spin dynamics in a one-dimensional subspace. Namely, the dynamics is captured by the absolute value of the magnetization, which is in a transient state, while its direction adiabatically follows the steady state. We define the hybrid state as the co-existence of these two states and identify the polar angle as the effective driving force of the spin dynamics. As an example, we optimize this drive for robust and efficient quantification of spin relaxation times and utilize it for magnetic resonance imaging of the human brain.

physics.med-ph