Dual-port grid-forming control of MMCs and its applications to grids of grids

This work focuses on grid-forming (GFM) control of Interconnecting Power Converters (IPCs) that are used to interconnect multiple HVAC and HVDC subgrids to form a grid of grids. We introduce the concept of dual-port GFM control that leverages the ability of Modular Multilevel Converters (MMCs) to simultaneously form its AC and DC terminal voltage and present two dual-port GFM MMC controls. We provide analytical results and high-fidelity simulations that demonstrate that (i) dual-port GFM control is more resilient to contingencies (i.e., line and generator outages) than state-of-the-art single-port GFM control, and (ii) unlike single-port GFM control, dual-port GFM control does not require assigning grid-forming and grid-following (GFL) roles to the IPC terminals in grids of grids. Finally, we provide an in-depth discussion and comparison of single-port GFM control and the proposed dual-port GFM controls.

eess.SY↗

A Lyapunov framework for nested dynamical systems on multiple time scales with application to converter-based power systems

In this work, we present a Lyapunov framework for establishing stability with respect to a compact set for a nested interconnection of nonlinear dynamical systems ordered from slow to fast according to their convergence rates, where each of the dynamics are influenced only by the slower dynamics and the successive fastest one. The proposed approach explicitly considers more than two time scales, it does not require modeling multiple time scales via scalar time constants, and provides analytic bounds that make ad-hoc time-scale separation arguments rigorous. Motivated by the technical results, we develop a novel control strategy for a grid-forming power converter that consists of an inner cascaded two-degree of freedom controller and dispatchable virtual oscillator control as a reference model. The resulting closed-loop converter-based AC power system is in the form of a nested system with multiple time scales. We apply our technical results to obtain explicit bounds on the controller set-points, branch powers, and control gains that guarantee almost global asymptotic stability of the multi-converter AC power system with respect to a pre-specified solution of the AC power-flow equations. Finally, we validate the performance of the proposed control structure in a case study using a high-fidelity simulation with detailed hardware validated converter models.

math.OC↗

Frequency Stability of Synchronous Machines and Grid-Forming Power Converters

An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage control mechanisms. This gradual transformation of the power system to a low-inertia system leads to critical challenges in maintaining system stability. Novel control techniques for converters, so-called grid-forming strategies, are expected to address these challenges and replicate functionalities that so far have been provided by synchronous machines. This article presents a low-inertia case study that includes synchronous machines and converters controlled under various grid-forming techniques. In this work 1) the positive impact of the grid-forming converters on the frequency stability of synchronous machines is highlighted, 2) a qualitative analysis which provides insights into the frequency stability of the system is presented, 3) we explore the behavior of the grid-forming controls when imposing the converter dc and ac current limitations, 4) the importance of the dc dynamics in grid-forming control design as well as the critical need for an effective ac current limitation scheme are reported, and lastly 5) we analyze how and when the interaction between the fast grid-forming converter and the slow synchronous machine dynamics can contribute to the system instability

eess.SY↗

Beyond low-inertia systems: Massive integration of grid-forming power converters in transmission grids

As renewable sources increasingly replace existing conventional generation, the dynamics of the grid drastically changes, posing new challenges for transmission system operations, but also arising new opportunities as converter-based generation is highly controllable in faster timescales. This paper investigates grid stability under the massive integration of grid-forming converters. We utilize detailed converter and synchronous machine models and describe frequency behavior under different penetration levels. First, we show that the transition from 0% to 100% can be achieved from a frequency stability point of view. This is achieved by re-tuning power system stabilizers at high penetration values. Second, we explore the evolution of the nadir and RoCoF for each generator as a function of the amount of inverter-based generation in the grid. This work sheds some light on two major challenges in low and no-inertia systems: defining novel performance metrics that better characterize grid behaviour, and adapting present paradigms in PSS design.

eess.SY↗

Interactions of Grid-Forming Power Converters and Synchronous Machines

An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage control mechanisms. This gradual transformation of the power system to a low-inertia system leads to critical challenges in maintaining system stability. Novel control techniques for converters, so-called grid-forming strategies, are expected to address these challenges and replicate functionalities that so far have been provided by synchronous machines. We present a low-inertia high-fidelity case study that includes synchronous machines and models of grid-forming converters. We study interactions between synchronous machines and converters and analyze the response of various grid-forming control approaches to contingencies, i.e., large changes in load and the loss of a synchronous machine. Our case study highlights the positive impact of the grid-forming converters on frequency stability and analyze the potential limitations of each control technique when interacting with synchronous machines. Our studies also analyze how and when the interaction between the fast grid-forming converter, the dc source and ac current limitations, and the slow synchronous machine dynamics contributes to system instability. Lastly, we introduce an effective solution to address the instability issues due to the GFCs ac and dc current limitation.

math.OC↗

The effect of transmission-line dynamics on grid-forming dispatchable virtual oscillator control

In this work, we analyze the effect of transmission line dynamics on grid-forming control for inverter-based AC power systems. In particular, we investigate a dispatchable virtual oscillator control (dVOC) strategy that was recently proposed in the literature. When the dynamics of the transmission lines are neglected, i.e., if an algebraic model of the transmission network is used, dVOC ensures almost global asymptotic stability of a network of AC power inverters with respect to a pre-specified solution of the AC power-flow equations. While this approximation is typically justified for conventional power systems, the electromagnetic transients of the transmission lines can compromise the stability of an inverter-based power system. In this work, we establish explicit bounds on the controller setpoints, branch powers, and control gains that guarantee almost global asymptotic stability of dVOC in combination with a dynamic model of the transmission network.

math.OC↗

Placement and Implementation of Grid-Forming and Grid-Following Virtual Inertia and Fast Frequency Response

The electric power system is witnessing a shift in the technology of generation. Conventional thermal generation based on synchronous machines is gradually being replaced by power electronics interfaced renewable generation. This new mode of generation, however, lacks the natural inertia and governor damping which are quintessential features of synchronous machines. The loss of these features results in increasing frequency excursions and, ultimately, system instability. Among the numerous studies on mitigating these undesirable effects, the main approach involves virtual inertia emulation to mimic the behavior of synchronous machines. In this work, explicit models of grid-following and grid-forming virtual inertia (VI) devices are developed for inertia emulation in low-inertia systems. An optimization problem is formulated to optimize the parameters and location of these devices in a power system to increase its resilience. Finally, a case study based on a high-fidelity model of the South-East Australian system is used to illustrate the effectiveness of such devices.

math.OC↗

Global phase and magnitude synchronization of coupled oscillators with application to the control of grid-forming power inverters

In this work, we explore a new approach to synchronization of coupled oscillators. In contrast to the celebrated Kuramoto model we do not work in polar coordinates and do not consider oscillations of fixed magnitude. We propose a synchronizing feedback based on relative state information and local measurements that induces consensus-like dynamics. We show that, under a mild stability condition, the combination of the synchronizing feedback with a decentralized magnitude control law renders the oscillators' almost globally asymptotically stable with respect to set-points for the phase shift, frequency, and magnitude. We apply these result to rigorously solve an open problem in control of inverter-based AC power systems. In this context, the proposed control strategy can be implemented using purely local information, induces a grid-forming behavior, and ensures that a network of AC power inverters is almost globally asymptotically stable with respect to a pre-specified solution of the AC power-flow equations. Moreover, we show that the controller exhibits a droop-like behavior around the standard operating point thus making it backward-compatible with the existing power system operation.

math.OC↗

Dispatchable Virtual Oscillator Control for Decentralized Inverter-dominated Power Systems: Analysis and Experiments

This paper presents an analysis and experimental validation of dispatchable virtual oscillator control (dVOC) for inverter-dominated power systems. dVOC is a promising decentralized control strategy that requires only local measurements to induce grid-forming behavior with programmable droop characteristics. It is dispatchable i.e., the inverters can vary their power generation via user-defined power set-points and guarantees strong stability. To verify its feasibility, a testbed comprising multiple dVOC-programmed inverters with transmission line impedances is designed. With an embedded synchronization strategy, the dVOC inverters are capable of dynamic synchronization, black start operation, and transient grid voltage regulation with dynamic load sharing, and real-time-programmable droop characteristics for backward compatibility. All these features are experimentally verified.

math.OC↗

On the steady-state behavior of a nonlinear power system model

In this article, we consider a dynamic model of a three-phase power system including nonlinear generator dynamics, transmission line dynamics, and static nonlinear loads. We define a synchronous steady-state behavior which corresponds to the desired nominal operating point of a power system and obtain necessary and sufficient conditions on the control inputs, load model, and transmission network, under which the power system admits this steady-state behavior. We arrive at a separation between the steady-state conditions of the transmission network and generators, which allows us to recover the steady-state of the entire power system solely from a prescribed operating point of the transmission network. Moreover, we constructively obtain necessary and sufficient steady-state conditions based on network balance equations typically encountered in power flow analysis. Our analysis results in several necessary conditions that any power system control strategy needs to satisfy.

math.OC↗