SearcharxivSearch

arXiv subjects

Dominik Panek

Publications and source records attributed to Dominik Panek.

3 recordsLinked to original sources

Democratizing Advanced High-Throughput Imaging via Cross-Instrument Deep Learning-Enabled Modality Transfer

High-throughput imaging is often constrained by a trade-off between acquisition speed and image quality. Fast imaging modalities, such as wide-field fluorescence microscopy, enable large-scale data acquisition but suffer from reduced contrast and resolution, whereas high-resolution techniques, like confocal or super-resolution techniques, provide superior image quality at the cost of reduced throughput and increased instrument time. Here, we present a deep learning-based approach for modality transfer across independent microscopes, enabling the transformation of low-quality images acquired on fast systems into high-quality representations comparable to those obtained using advanced imaging platforms. To achieve this, we employed a generative adversarial network (GAN)-based model trained on paired datasets acquired on physically separate wide-field and confocal microscopes, demonstrating that image quality can be reliably transferred between independent instruments. Importantly, this approach enables a workflow in which high-throughput imaging can be performed on fast, accessible microscopy systems while preserving the ability to computationally recover high-quality structural information. High-resolution microscopy can then be reserved for algorithm training and targeted validation, reducing acquisition time and improving overall experimental efficiency. This workflow supports a model in which shared imaging facilities provide access to advanced instrumentation without requiring individual research groups to procure dedicated high-end systems. Together, our results establish deep learning-enabled modality transfer as a practical strategy for bridging independent microscopy systems and supporting scalable, high-content imaging workflows.

eess.IV

Feasibility of the J-PET to monitor range of therapeutic proton beams

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.

physics.med-ph

Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alternative. The work aimed to compare five Total-Body J-PET geometries as a possible next generation J-PET scanner design. We present comparative studies of performance characteristics of the cost-effective Total-Body PET scanners using J-PET technology. We investigated in silico five Total-Body scanner geometries. Monte Carlo simulations of the XCAT phantom, the 2-meter sensitivity line source and positronium sensitivity phantoms were performed. We compared the sensitivity profiles for 2-gamma and 3-gamma tomography, relative cost of the setups and performed quantitative analysis of the reconstructed images. The analysis of the reconstructed XCAT images reveals the superiority of the seven-ring scanners over the three-ring setups. However, the three-ring scanners would be approximately 2-3 times cheaper. The peak sensitivity values for two-gamma vary from 20 to 34 cps/kBq. The sensitivity curves for the positronium tomography have a similar shape to the two-gamma sensitivity profiles. The peak values are lower compared to the two-gamma cases, from about 20-28 times, with a maximum of 1.66 cps/kBq. The results show the feasibility of multi-organ imaging of all the systems to be considered for the next generation of TB J-PET designs. The relative cost for all the scanners is about 10-4 times lower compared to the cost of the uExplorer. These properties coupled together with J-PET cost-effectiveness, make the J-PET technology an attractive solution for broad application in clinics.

physics.med-ph