Intra-operative quantification of the surgical gesture in orbital surgery: Application to the proptosis reduction

Proptosis is characterized by a protrusion of the eyeball due to an increase of the orbital tissue volume. To recover a normal eyeball positioning, the most frequent surgical technique (BROD technique) consists in the osteotomy of orbital walls combined with a loading on the eyeball to initiate tissue decompression. This paper proposed an experimental method to quantify the intra-operative clinical gesture in proptosis reduction, and the pilot study concerned one clinical case. The eyeball's backward displacement was measured by an optical 3D localizer and the load applied by the surgeon was simultaneously measured by a custom-made force gauge. Quasi-static stiffness of the intra-orbital content was evaluated. The average values for the whole experiment was 16 N (SD: 3 N) for the force exerted by the surgeon and 9 mm (SD: 4 mm) for the eyeball backward displacement. The averaged quasi-static stiffness of the orbital content was evaluated to 2.4 N/mm (SD: 1.2) and showed a global decrease of 45% post-operatively.

physics.med-ph

A stiffness sensor to help in the diagnosis and the surgery of orbital pathologies

Proptosis is characterized by a protrusion of the eyeball due to an increase of the orbital tissue volume. To recover a normal eyeball positioning, the most frequent surgical technique (BROD technique) consists in the osteotomy of orbital walls combined with a loading on the eyeball to initiate tissue decompression. In this paper, a stiffness sensor device is proposed to (1) provide to the surgeon pre, intra and post-operative data concerning the stiffness of the intra-orbital soft tissues, and (2) provide constitutive parameters to the Finite Element model of the intra-orbital tissues already developed by the authors and used to predict consequences orbital surgery.

physics.med-ph

A finite element study of the influence of the osteotomy surface on the backward displacement during exophthalmia reduction

Exophthalmia is characterized by a protrusion of the eyeball. The most frequent surgery consists in an osteotomy of the orbit walls to increase the orbital volume and to retrieve a normal eye position. Only a few clinical obser-vations have estimated the relationship between the eyeball backward dis-placement and the decompressed fat tissue volume. This paper presents a method to determine the relationship between the eyeball backward displace-ment and the osteotomy surface made by the surgeon, in order to improve ex-ophthalmia reduction planning. A poroelastic finite element model involving morphology, material properties of orbital components, and surgical gesture is proposed to perform this study on 12 patients. As a result, the osteotomy sur-face seems to have a non-linear influence on the backward displacement. More-over, the FE model permits to give a first estimation of an average law linking those two parameters. This law may be helpful in a surgical planning frame-work.

physics.med-ph

Prediction of tissue decompression in orbital surgery

Objective: A method to predict the relationships between decompressed volume of orbital soft tissues, backward displacement of globe after osteotomy, and force exerted by the surgeon, was proposed to improve surgery planning in exophthalmia reduction. Design: A geometric model and a poroelastic finite element model were developed, based on Computed Tomography scan data. Background: The exophthalmia is characterised by a protrusion of the eyeball. Surgery consists in an osteotomy of the orbit walls to decompress the orbital content. A few clinical observations ruling on an almost linear relationship between globe backward displacement and tissue decompressed volume are described in the literature. Methods: Fast prediction of decompressed volume is derived from the geometric model: a sphere in interaction with a cone. Besides, a poroelastic Finite Element model involving morphology, material properties of orbital components and surgical gesture was implemented. Results: The geometric model provided a better decompression volume estimation than the Finite Element model. Besides, the Finite Element model permitted to quantify the backward displacement, the surgical gesture and the stiffness of the orbital content. Conclusions: The preliminary results obtained for one patient, in accordance with the clinical literature, were relatively satisfying. An efficient aid for location and size of osteotomies was derived and seemed to be able to help in the surgery planning. Relevance: To our knowledge, this paper concerns the first biomechanical study of exophthalmia reduction. The approach permitted to improve the treatment of orbitopathy and can be used in a clinical setting.

physics.med-ph

Computer assisted planning and orbital surgery: patient-related prediction of osteotomy size in proptosis reduction

BACKGROUND: Proptosis is characterized by a protrusion of the eyeball due to an increase of the orbital tissue volume. To recover a normal eyeball positioning, the most frequent surgical technique consists in the osteotomy of orbital walls combined with the manual loading on the eyeball. Only a rough clinical rule is currently available for the surgeons but it is useless for this technique. The first biomechanical model dealing with proptosis reduction, validated in one patient, has been previously proposed by the authors. METHODS: This paper proposes a rule improving the pre-operative planning of the osteotomy size in proptosis reduction. Patient-related poroelastic FE models combined with sensitivity studies were used to propose two clinical rules to improve the pre-operative planning of proptosis reduction. This poroelastic model was run on 12 patients. Sensitivity studies permitted to establish relationships between the osteotoemy size, the patient-related orbital volume, the decompressed tissue volume and the eyeball backward displacement. FINDINGS: The eyeball displacement and the osteotomy size were non-linearly related: an exponential rule has been proposed. The patient-related orbital volume showed a significant influence: a bi-quadratic analytical equation liking the osteotomy size, the orbital volume and the targeted eyeball protrusion has been established. INTERPRETATION: Two process rules derived from patient-related biomechanical FE models have been proposed for the proptosis reduction planning. The implementation of the process rules into a clinical setting is easy since only a sagittal radiography is required. The osteotomy size can be monitored using optical guided instruments.

physics.med-ph