SearcharxivSearch

arXiv subjects

Dong-Chel Shin

Publications and source records attributed to Dong-Chel Shin.

3 recordsLinked to original sources

Continuum-field quantum optics of frequency comb metrology

Frequency combs enable precision measurements across timekeeping, spectroscopy, ranging and astronomy, and are now extending to integrated and field-deployable platforms. Realizing their full performance demands a comprehensive account of the quantum noise that arises when broadband optical fields are converted into finite-bandwidth electrical signals. Here we present a rigorous first-principles quantum-mechanical framework for optical frequency-comb metrology based on continuous-mode field quantization and a comb-line-resolved description of quantum fluctuations. The theory describes how quantum fluctuations of the comb field are transduced into electrical measurement noise. Formulated at the level of the comb field, the framework unifies the standard quantum limits of optical frequency division (OFD) and dual-comb spectroscopy (DCS) within a single treatment, and provides a general recipe for other comb-based measurements. On this footing, we identify practical, resource-efficient routes to quantum enhancement through engineered comb states, laying a foundation for the design of next-generation frequency combs operating at and beyond standard quantum limits.

quant-ph

Active laser cooling of a centimeter-scale torsional oscillator

Experimental tests of gravity's fundamental nature call for mechanical systems in the quantum regime while being sensitive to gravity. Torsion pendula, historically vital in studies of classical gravity, are ideal for extending gravitational tests into the quantum realm due to their inherently high mechanical quality factor, even when mass-loaded. Here, we demonstrate laser cooling of a centimeter-scale torsional oscillator to a temperature of 10 mK (average occupancy of 6000 phonons) starting from room temperature. This is achieved by optical radiation pressure forces conditioned on a quantum-noise-limited optical measurement of the torsional mode with an imprecision 9.8 dB below its peak zero-point motion. The measurement sensitivity is the result of a novel `mirrored' optical lever that passively rejects extraneous spatial-mode noise by 60 dB. The high mechanical quality ($1.4\times 10^7$) and quantum-noise-limited measurement imprecision demonstrate the necessary ingredients for realizing the quantum ground state of torsional motion -- a pre-requisite for mechanical tests of gravity's alleged quantum nature.

quant-ph

Temperature stabilization of a lab space at $10\,\mathrm{mK}$-level over a day

Temperature fluctuations over long time scales ($\gtrsim 1\,\mathrm{h}$) are an insidious problem for precision measurements. In optical laboratories, the primary effect of temperature fluctuations is drifts in optical circuits over spatial scales of a few meters and temporal scales extending beyond a few minutes. We present a lab-scale environment temperature control system approaching $10\, \mathrm{mK}$-level temperature instability across a lab for integration times above an hour and extending to a few days. This is achieved by passive isolation of the laboratory space from the building walls using a circulating air gap and an active control system feeding back to heating coils at the outlet of the laboratory HVAC unit. The latter achieves 20 dB suppression of temperature fluctuations across the lab, approaching the limit set by statistical coherence of the temperature field.

physics.ins-det