SearcharxivSearch

arXiv subjects

Dong-Yang Jing

Publications and source records attributed to Dong-Yang Jing.

2 recordsLinked to original sources

Polarization and fundamental sensitivity of $^{\text{39}}$K ($^{\text{133}}$Cs)-$^{\text{85}}$Rb-$^{\text{21}}$Ne co-magnetometers

The hybrid optical pumping spin exchange relaxation free (HOPSERF) atomic co-magnetometers make ultrahigh sensitivity measurement of inertia achievable. The wall relaxation rate has a big effect on the polarization and fundamental sensitivity for the co-magnetometer, but it is often neglected in the experiments. However, there is almost no work about the systematic analysis of the influence factors on the polarization and the fundamental sensitivity of the HOPSERF co-magnetometers. Here, we systematically study the polarization and the fundamental sensitivity of 39K-85Rb-21Ne and 133Cs-85Rb-21Ne HOPSERF co-magnetometers with low polarization limit and the wall relaxation rate. The 21Ne number density, the power density and wavelength of pump beam will affect the polarization greatly by affecting the pumping rate of pump beam. We obtain a general formula on the fundamental sensitivity of the HOPSERF co-magnetometers due to shot-noise and the fundamental sensitivity changes with multiple systemic parameters, where the suitable number density of buffer gas and quench gas make the fundamental sensitivity highest. The fundamental sensitivity $7.5355\times10^{-11}$ $\rm rad/s/Hz^{1/2}$ of 133Cs-85Rb-21Ne co-magnetometer is higher than the ultimate theoretical sensitivity $2\times10^{-10}$ $\rm rad/s/Hz^{1/2}$ of K-21Ne co-magnetometer.

physics.atom-ph

The polarization and the fundamental sensitivity of $^{39}$K ($^{133}$Cs)-$^{85}$Rb-$^{4}$He hybrid optical pumping spin exchange relaxation free atomic magnetometers

The hybrid optical pumping spin exchange relaxation free (SERF) atomic magnetometers can realize ultrahigh sensitivity measurement of magnetic field and inertia. We have studied the $^{\text{85}}$Rb polarization of two types of hybrid optical pumping SERF magnetometers based on $^{\text{39}}$K-$^{\text{85}}$Rb-$^{\text{4}}$He and $^{\text{133}}$Cs-$^{\text{85}}$Rb-$^{\text{4}}$He respectively. Then we found that $^{\text{85}}$Rb polarization varies with the number density of buffer gas $^{\text{4}}$He and quench gas N$_{\text{2}}$, pumping rate of pump beam and cell temperature respectively, which will provide an experimental guide for the design of the magnetometer. We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF magnetometer due to shot-noise. The formula describes that the fundamental sensitivity of the magnetometer varies with the number density of buffer gas and quench gas, the pumping rate of pump beam, external magnetic field, cell effective radius, measurement volume, cell temperature and measurement time. We obtain a highest fundamental sensitivity of $1.5073$ $aT/Hz^{1/2}$ ($1$ $aT=10^{-18}$ $T$) with $^{\text{39}}$K-$^{\text{85}}$Rb-$^{\text{4}}$He magnetometer between above two types of magnetometers when $^{\text{85}}$Rb polarization is $0.1116$. We estimate the fundamental sensitivity limit of the hybrid optical pumping SERF magnetometer to be superior to $1.8359\times10^{-2}$ $aT/Hz^{1/2}$, which is higher than the shot-noise-limited sensitivity of $1$ $aT/Hz^{1/2}$ of K SERF atomic magnetometer.

physics.atom-ph