SearcharxivSearch

arXiv subjects

Dongho Shin

Publications and source records attributed to Dongho Shin.

6 recordsLinked to original sources

Leveraging Fine-grained Error Correction in Korean Speech Recognition for Consultation Services

Automatic Speech Recognition (ASR) technology is fundamental to customer service automation and large-scale transcription. However, even advanced ASR models exhibit inevitable errors in complex real-world environments such as call center conversations. When privacy restrictions preclude audio access, error correction must rely on text-based post-editing. Existing text-only approaches face significant challenges in low-resource languages, mainly due to a critical scarcity of annotated corpora and tailored correction methodologies. For Korean, this resource gap is particularly pronounced, as existing resources are predominantly designed for ASR training rather than text-based error correction. To address this, we introduce DasanCallDial, the first large-scale Korean benchmark dataset specifically curated for dialogue-level ASR error correction. Derived from genuine call center interactions, it comprises 1,974 dialogues with 115,460 utterances. Leveraging this resource, we propose Detector-Gated Contextual Span Correction (DCSC), a text-only post-editing framework for error-sparse Korean speech recognition transcripts. DCSC combines an encoder-based detector that first performs token-level error detection, followed by a language model-based corrector trained to rectify fine-grained span-level errors. Additionally, we employ dialogue-level context augmentation to enable the model to leverage discourse history for disambiguation. By employing multi-level granularity, our method achieves state-of-the-art performance, effectively overcoming the limitations of general LLMs in low-resource settings.

cs.CL

Effect of Electrode Array Position on Electric Field Intensity in Glioblastoma Patients Undergoing Electric Field Therapy

Background: The intensity of the electric field applied to a brain tumor by electric field therapy is influenced by the position of the electrode array, which should be optimized based on the patient's head shape and tumor characteristics. This study assessed the effects of varying electrode positions on electric field intensity in glioblastoma multiforme (GBM) patients. Methods: This study enrolled 13 GBM patients. The center of the MR slice corresponding to the center of the tumor was set as the reference point for the electrodes, creating pairs of electrode arrays in the top-rear and left-right positions. Based on this reference plan, four additional treatment plans were generated by rotating three of the four electrode arrays, all except the top electrode array, by 15$^\circ$ and 30$^\circ$ from their reference positions, resulting in a total of five treatment plans per patient. Electric field frequency was set at 200 kHz, and current density at 31 mArms/cm$^2$. The minimum and mean electric field intensities, homogeneity index (HI), and coverage index (CovI) were calculated and compared. Results: The optimal plans showed differences ranging from-0.39% to 24.20% for minimum intensity and -14.29% to 16.67% for mean intensity compared to reference plans. HI and CovI varied from 0.00% to 48.65% and 0.00% to 95.3%, respectively. The average improvements across all patients were 8.96% for minimum intensity, 5.11% for mean intensity, 15.65% for HI, and 17.84% for CovI. Conclusions: Optimizing electrode angle improves electric field therapy outcomes in GBM patients by maximizing field intensity and coverage. Keywords: electric field therapy; glioblastoma multiforme (GBM); treatment planning system (TPS); electrode array position; tumor coverage

physics.med-ph

Compatible Imputation for Hierarchical Linear Models with Incomplete Data: Interaction Effects of Continuous and Categorical Covariates MAR

This article focuses on Bayesian estimation of a hierarchical linear model (HLM) from incomplete data assumed missing at random where continuous covariates C and discrete categorical covariates $D$ have interaction effects on a continuous response $R$. Given small sample sizes, maximum likelihood estimation is suboptimal, and existing Gibbs samplers are based on a Bayesian joint distribution compatible with the HLM, but impute missing values of $C$ and the underlying latent continuous variables $D^*$ of $D$ by a Metropolis algorithm via proposal normal densities having constant variances while the target conditional distributions of $C$ and $D$ have nonconstant variances. Therefore, the samplers are neither guaranteed to be compatible with the joint distribution nor ensured to always produce unbiased estimation of the HLM. We assume a Bayesian joint distribution of parameters and partially observed variables, including correlated categorical $D$, and introduce a compatible Gibbs sampler that draws parameters and missing values directly from the exact posterior distributions. We apply our sampler to incompletely observed longitudinal data from the small number of patient-physician encounters during office visits, and compare our estimators with those of existing methods by simulation.

stat.ME

Bayesian Estimation of Hierarchical Linear Models from Incomplete Data: Cluster-Level Interaction Effects and Small Sample Sizes

We consider Bayesian estimation of a hierarchical linear model (HLM) from partially observed data, assumed to be missing at random, and small sample sizes. A vector of continuous covariates $C$ includes cluster-level partially observed covariates with interaction effects. Due to small sample sizes from 37 patient-physician encounters repeatedly measured at four time points, maximum likelihood estimation is suboptimal. Existing Gibbs samplers impute missing values of $C$ by a Metropolis algorithm using proposal densities that have constant variances while the target posterior distributions have nonconstant variances. Therefore, these samplers may not ensure compatibility with the HLM and, as a result, may not guarantee unbiased estimation of the HLM. We introduce a compatible Gibbs sampler that imputes parameters and missing values directly from the exact posterior distributions. We apply our Gibbs sampler to the longitudinal patient-physician encounter data and compare our estimators with those from existing methods by simulation.

stat.ME

Simulation study of dose enhancement in a cell due to nearby carbon and oxygen in particle radiotherapy

The aim of this study is to investigate the dose-deposition enhancement by alpha-particle irradiation in a cellular model using carbon and oxygen chemical compositions.A simulation study was performed to study dose enhancement due to carbon and oxygen for a human cell where Geant4 code used for the alpha-particle irradiation to the cellular phantom. The characteristic of dose enhancement in the nucleus and cytoplasm by the alpha-particle radiation was investigated based on concentrations of the carbon and oxygen compositions and was compared with those by gold and gadolinium.The results show that both the carbon and oxygen-induced dose enhancement was found to be more effective than those of gold and gadolinium. We found that the dose-enhancement effect was more dominant in the nucleus than in the cytoplasm if carbon or oxygen is uniformly distributed in a whole cell. In the condition that the added chemical composition was inserted only into the cytoplasm, the effect of the dose enhancement in nucleus becomes weak.We showed that high-stopping-power materials offer a more effective dose-enhancement efficacy and suggest that the carbon nanotubes and oxygenation are promising candidates for dose utilization as dose enhancement tools in particle therapy.

physics.med-ph

Treatment plan comparison of Linac step and shoot,Tomotherapy, RapidArc, and Proton therapy for prostate cancer using dosimetrical and biological index

The purpose of this study was to use various dosimetrical indices to determine the best IMRT modality technique for treating patients with prostate cancer. Ten patients with prostate cancer were included in this study. Intensity modulated radiation therapy plans were designed to include different modalities, including the linac step and shoot, Tomotherapy, RapidArc, and Proton systems. Various dosimetrical indices, like the prescription isodose to target volume (PITV) ratio, conformity index (CI), homogeneity index (HI), target coverage index (TCI), modified dose homogeneity index (MHI), conformation number (CN), critical organ scoring index (COSI), and quality factor (QF) were determined to compare the different treatment plans. Biological indices such as the generalized equivalent uniform dose (gEUD), based tumor control probability (TCP), and normal tissue complication probability (NTCP) were also calculated and used to compare the treatment plans. The RapidArc plan attained better PTV coverage, as evidenced by its superior PITV, CI, TCI, MHI, and CN values. Regarding OARs, proton therapy exhibited superior dose sparing for the rectum and bowel in low dose volumes, whereas the Tomotherapy and RapidArc plans achieved better dose sparing in high dose volumes. The QF scores showed no significant difference among these plans (p=0.701). The average TCPs for prostate tumors in the RapidArc, Linac, and Proton plans were higher than the average TCP for Tomotherapy (98.79%, 98.76%, and 98.75% vs. 98.70%, respectively). Regarding the rectum NTCP, RapidArc showed the most favorable result (0.09%), whereas Linac resulted in the best bladder NTCP (0.08%).

physics.med-ph