Searcharxiv⌕ Search

arXiv subjects

Dorri Halbertal

Publications and source records attributed to Dorri Halbertal.

23 records · Page 2Linked to original sources

Nanoscale thermal imaging of dissipation in quantum systems

Energy dissipation is a fundamental process governing the dynamics of physical, chemical, and biological systems. It is also one of the main characteristics distinguishing quantum and classical phenomena. In condensed matter physics, in particular, scattering mechanisms, loss of quantum information, or breakdown of topological protection are deeply rooted in the intricate details of how and where the dissipation occurs. Despite its vital importance the microscopic behavior of a system is usually not formulated in terms of dissipation because the latter is not a readily measureable quantity on the microscale. Although nanoscale thermometry is gaining much recent interest, the existing thermal imaging methods lack the necessary sensitivity and are unsuitable for low temperature operation required for study of quantum systems. Here we report a superconducting quantum interference nano-thermometer device with sub 50 nm diameter that resides at the apex of a sharp pipette and provides scanning cryogenic thermal sensing with four orders of magnitude improved thermal sensitivity of below 1 μK/Hz1/2. The non-contact non-invasive thermometry allows thermal imaging of very low nanoscale energy dissipation down to the fundamental Landauer limit of 40 fW for continuous readout of a single qubit at 1 GHz at 4.2 K. These advances enable observation of dissipation due to single electron charging of individual quantum dots in carbon nanotubes and reveal a novel dissipation mechanism due to resonant localized states in hBN encapsulated graphene, opening the door to direct imaging of nanoscale dissipation processes in quantum matter.

cond-mat.mes-hall↗

Probing dynamics and pinning of single vortices in superconductors at nanometer scales

The dynamics of quantized magnetic vortices and their pinning by materials defects determine electromagnetic properties of superconductors, particularly their ability to carry non-dissipative currents. Despite recent advances in the understanding of the complex physics of vortex matter, the behavior of vortices driven by current through a multi-scale potential of the actual materials defects is still not well understood, mostly due to the scarcity of appropriate experimental tools capable of tracing vortex trajectories on nanometer scales. Using a novel scanning superconducting quantum interference microscope we report here an investigation of controlled dynamics of vortices in lead films with sub-Angstrom spatial resolution and unprecedented sensitivity. We measured, for the first time, the fundamental dependence of the elementary pinning force of multiple defects on the vortex displacement, revealing a far more complex behavior than has previously been recognized, including striking spring softening and broken-spring depinning, as well as spontaneous hysteretic switching between cellular vortex trajectories. Our results indicate the importance of thermal fluctuations even at 4.2 K and of the vital role of ripples in the pinning potential, giving new insights into the mechanisms of magnetic relaxation and electromagnetic response of superconductors.

cond-mat.supr-con↗

A three-junction SQUID-on-tip with tunable in-plane and out-of-plane magnetic field sensitivity

Nanoscale superconducting quantum interference devices (SQUIDs) demonstrate record sensitivities to small magnetic moments, but are typically sensitive only to the field component that is normal to the plane of the SQUID and out-of-plane with respect to the scanned surface. We report on a nanoscale three-junction Pb SQUID which is fabricated on the apex of a sharp tip. Because of its three-dimensional structure, it exhibits a unique tunable sensitivity to both in-plane and out-of-plane fields. We analyze the two-dimensional interference pattern from both numerical and experimental points of view. This device is integrated into a scanning microscope and its ability to independently measure the different components of the magnetic field with outstanding spin sensitivity better than $5\ \frac{μ_B}{\mathrm{Hz}^{1/2}}$ is demonstrated. This highlights its potential as a local probe of nanoscale magnetic structures.

cond-mat.supr-con↗

Numeric spectral radiation hydrodynamic calculations of supernova shock breakouts

We present here an efficient numerical scheme for solving the non-relativistic 1D radiation-hydrodynamics equations including inelastic Compton scattering, which is not included in most codes and is crucial for solving problems such as shock breakout. The devised code is applied to the problems of a steady-state planar radiation mediated shock (RMS) and RMS breakout from a stellar envelope. The results are in agreement with those of a previous work on shock breakout \citep{Sapir13}, in which Compton equilibrium between matter and radiation was assumed and the "effective photon" approximation was used to describe the radiation spectrum. In particular, we show that the luminosity and its temporal dependence, the peak temperature at breakout, and the universal shape of the spectral fluence derived in this earlier work are all accurate. Although there is a discrepancy between the spectral calculations and the effective photon approximation due to the inaccuracy of the effective photon approximation estimate of the effective photon production rate, which grows with lower densities and higher velocities, the difference in peak temperature reaches only $30\%$ for the most discrepant cases of fast shocks in blue supergiants. The incompatibility of the stellar envelope shock breakout model results with observed properties of X-ray flashes and the discrepancy between the predicted and observed rates of X-ray flashes \citep{Sapir13} remain unexplained.

astro-ph.HE↗

Scanning nano-SQUID with single electron spin sensitivity

One of the critical milestones in the intensive pursuit of quantitative nanoscale magnetic imaging tools is achieving the level of sensitivity required for detecting the field generated by the spin magnetic moment μB of a single electron. Superconducting quantum interference devices (SQUIDs), which were traditionally the most sensitive magnetometers, could not hitherto reach this goal because of their relatively large effective size (of the order of 1 μm). Here we report self-aligned fabrication of nano-SQUIDs with diameters as small as 46 nm and with an extremely low flux noise of 50 nΦ0/Hz^1/2, representing almost two orders of magnitude improvement in spin sensitivity, down to 0.38 μB/Hz^1/2. In addition, the devices operate over a wide range of magnetic fields with 0.6 μB/Hz^1/2 sensitivity even at 1 T. We demonstrate magnetic imaging of vortices in type II superconductor that are 120 nm apart and scanning measurements of AC magnetic fields down to 50 nT. The unique geometry of these nano-SQUIDs that reside on the apex of a sharp tip allows approaching the sample to within a few nm, which paves the way to a new class of single-spin resolved scanning probe microscopy.

cond-mat.supr-con↗