Operation of Unshielded Kinetic-Inductance Traveling-Wave Parametric Amplifiers in Multi-Tesla Fields

Cryogenic parametric amplifiers are used to amplify radio-frequency signals for a range of applications in basic and applied science. Both Josephson Parametric Amplifiers and Josephson Traveling-Wave Parametric Amplifiers have been used as first-stage amplifiers enabling readout chains operating within a few quanta of the quantum limit. However, these devices are highly sensitive to magnetic fields, having critical current suppressed by the Fraunhofer effect, requiring substantial field-free zones. In a dark matter axion search experiment, axions convert to detectable microwave photons in the presence of a strong magnetic field, necessitating amplifiers that can reliably operate close to these environments. Kinetic-inductance Traveling-Wave Parametric Amplifiers (KTWPAs) may be the ideal candidate for this type of application having high critical magnetic field of the materials used throughout their construction. In this letter we demonstrate that KTWPAs can provide high gain (>20dB) over a multi-GHz bandwidth in spite of from multiple exposures to multi-Tesla fields. Further, we explore operational characteristics of these devices under harsh conditions as a function of overall field strength, device orientation within the field, applied bias current, and pump power & frequency. In so doing, we find KTWPA gain vanishes in devices oriented perpendicularly to a field of 0.02T, but gain values >10dB are achievable in fields over 1T when oriented near~parallel to the device plane, with peak gain achieved with an applied 0.25T to 0.5T field. It is our expectation that KTWPAs will expand the accessibility of quantum-limited RF measurements in the presence of Tesla-scale fields.

hep-ex

Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8

We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron X-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of $4$~eV at 6~keV at a rate of about 1~c/s/pixel. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of about 2 x 10^3 c/s/all pixels with an energy resolution of 5 eV at 6 keV. By utilizing the TES's wide-band spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted X-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The neighboring lines of As K alpha and Pb L alpha2 of the standard sample were clearly resolved and the XANES of Pb L alpha2 was obtained. Moreover, the X-ray spectrum from the small amount of Fe in aerosols was distinguished from the spectrum of a blank target, which helps us to understand the targets and the environment. These results are the first important step for the application of high resolution TES-based spectroscopy at hard X-ray synchrotron facilities.

astro-ph.IM

Design of a mission to measure the shape and substructure of the 511 keV gamma-ray line from the center of the Milky Way

The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. In this paper, we describe a concept for a balloon-borne 511 keV $\gamma$-ray mission called the 511-Spectrometer Mission. The mission will use Transition-Edge Sensor (TES) arrays with thick metal absorbers that are thermally coupled to the TES. The strength of the approach is a projected energy resolution of 200 eV Full Width Half Maximum (FWHM) at 511 keV, enabling detailed studies of the shape and substructure of the 511 keV emission from the galactic center region. A first mission equipped with 8,192 $\gamma$-ray detectors and a fully active shield and collimator could detect the galactic center with ~35 $\sigma$ statistical significance. We present the mission concept as well as first results obtained with a prototype detector equipped with $1.35\times1.35\times2$ mm$^{3}$ Bi absorbers. The detector has a quantum efficiency of 15% for 511 keV photons in photoelectric effect interactions. In tests with a $^{137}$Cs source, these prototype detectors show an energy resolution of 525 eV FWHM at 662 keV. We end with a discussion of follow-up missions that use coded mask imaging, or use concentrating or focusing optics to scrutinize the sources of 511 keV $\gamma$-rays on smaller angular scales.

astro-ph.IM

Imaging the Superconducting Proximity Effect in S-S'-S Transition Edge Sensors

Proximity effects at superconducting interfaces, between different superconductors (S-S') or between superconductors and normal metals (S-N), are fundamental to the performance of superconducting electronics, yet only few experiments have directly probed the spatial structure of proximity effects within a device. This is particularly relevant for transition edge sensors (TESs), where the interplay of direct and inverse proximity effects governs detector sensitivity. Here, we use scanning superconducting interference device (SQUID) susceptometry to directly image the local diamagnetic response in functional S-S'-S TES structures. We resolve long range proximity coupling extending over tens of micrometers, revealing that the local transition temperature is dramatically tuned by neighboring regions, being either enhanced by superconducting (S) leads or suppressed by normal metal (N) contacts. Our observations are quantitatively supported by Ginzburg Landau modeling of the device geometry and calculations of the temperature dependent diamagnetism based on self-consistent Usadel equations. By providing spatially resolved measurements of the interplay of proximity effects in TES devices, this work establishes a framework for understanding and controlling superconducting states in heterogeneous superconducting structures.

cond-mat.supr-con

Effective reflection mode measurement for hanger-coupled microwave resonators

Superconducting microwave resonators are used in many low-power applications, such as the study of two-level system loss in superconducting quantum devices. Fano asymmetry, characterized by a nonzero asymmetry angle $\phi$ in the diameter correction method, results from the coupling schemes used to measure these devices, including the commonly used hanger method. $\phi$ is an additional fitting parameter which contains no physically interesting information and can obscure device parameters of interest. The T-junction symmetry nominally present in these resonator devices provides an avenue for the elimination of Fano asymmetry using calibrated measurement. We show that the eigenvalue associated with the common mode excitation of the resonator is an effective reflection mode (ERM) which has no Fano asymmetry. Our analysis reveals the cause of Fano asymmetry as interference between common and differential modes. Practically, we obtain the ERM from a linear combination of calibrated reflection and transmission measurements. We utilize a three-dimensional aluminum cavity to experimentally demonstrate the validity and flexibility of this model. To extend the usefulness of this symmetry analysis, we apply perturbation theory to recover the ERM in a multiplexed coplanar waveguide resonator device and experimentally demonstrate quantitative agreement in the extracted $Q_i^{-1}$ between hanger mode and ERM measurements. We observe a fivefold reduction in uncertainty from the ERM compared to the standard hanger mode at the lowest measured power, $-160$ dBm delivered to the device. This method could facilitate an increase in throughput of low-power superconducting resonator measurements by up to a factor of 25, as well as allow the extraction of critical parameters from otherwise unfittable device data.

quant-ph

Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment

We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $^{163}$Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $^{163}$Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $^{163}$Ho to be $(2.9 \pm 0.4 \mathrm{(stat)} \pm 0.7 \mathrm{(sys)})$ J/K/mol at $(94 \pm 1)$\,mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $^{163}$Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $^{163}$Ho activities up to approximately 5 Bq without significant performance degradation. For higher activities, reducing the TES transition temperature is necessary to maintain energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling implanted radionuclides while maintaining high-resolution performance.

physics.ins-det

Direct Imaging of Transition-Edge Sensors with Scanning SQUID Microscopy

Significant advancements have been made in understanding the physics of transition-edge sensors (TESs) over the past decade. However, key questions remain, particularly a detailed understanding of the current-dependent resistance of these detectors when biased within their superconducting transition. We use scanning superconducting quantum interference device (SQUID) microscopy (SSM) to image the local diamagnetic response of aluminum-manganese alloy (Al-Mn) transition-edge sensors (TESs) near their critical temperature of approximately 175 mK. By doing so, we gain insights into how the device dimensions influence TES transition width, which in turn affects device operation and informs optimal device design. Our images reveal that the Al-Mn thin film near the niobium (Nb) leads exhibits an excess diamagnetic response at temperatures several milli-Kelvin (mK) higher than the bulk of the film farther from the contacts. A possible origin of this behavior is a longitudinal proximity effect between the Nb and Al-Mn where the TES acts as a weak link between superconducting leads. We discuss how this effect shapes the temperature dependence of the resistance as the spacing between the leads decreases. This work demonstrates that magnetic imaging with SSM is a powerful tool for local characterization of superconducting detectors.

cond-mat.supr-con

ASCENT - A balloon-borne hard X-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. The isotope ${}^{44}$Ti is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard X-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called ASCENT (A SuperConducting ENergetic x-ray Telescope). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55 eV Full Width Half Maximum (FWHM) energy resolution at 97 keV. This 8--16-fold improvement in energy resolution over NuSTAR will allow high resolution imaging and spectroscopy of the ${}^{44}$Ti emission. This will allow a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as: What is the source of the neutron star "kicks"? What is the dominant production pathway for ${}^{44}$Ti? Is the engine of Cas A unique?

astro-ph.IM

The 511-CAM Mission: A Pointed 511 keV Gamma-Ray Telescope with a Focal Plane Detector Made of Stacked Transition Edge Sensor Microcalorimeter Arrays

The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from the interstellar medium. Alternatively, the positrons could be created by astrophysical sources, involving exclusively standard model physics. We describe here a new concept for a 511 keV mission called 511-CAM (511 keV gamma-ray CAmera using Micro-calorimeters) that combines focusing gamma-ray optics with a stack of Transition Edge Sensor (TES) microcalorimeter arrays in the focal plane. The 511-CAM detector assembly has a projected 511 keV energy resolution of 390 eV Full Width Half Maximum (FWHM) or better, and improves by a factor of at least 11 on the performance of state-of-the-art Ge-based Compton telescopes. Combining this unprecedented energy resolution with sub-arcmin angular resolutions afforded by Laue lens or channeling optics could make substantial contributions to identifying the origin of the 511 keV emission by discovering and characterizing point sources and measuring line-of-sight velocities of the emitting plasmas.

astro-ph.IM