Searcharxiv⌕ Search

arXiv subjects

Duong Thanh Tai

Publications and source records attributed to Duong Thanh Tai.

2 recordsLinked to original sources

Application of Quantum Convolutional Neural Networks for MRI-Based Brain Tumor Detection and Classification

This study explores the application of Quantum Convolutional Neural Networks (QCNNs) for brain tumor classification using MRI images, leveraging quantum computing for enhanced computational efficiency. A dataset of 3,264 MRI images, including glioma, meningioma, pituitary tumors, and non-tumor cases, was utilized. The data was split into 80% training and 20% testing, with an oversampling technique applied to address class imbalance. The QCNN model consists of quantum convolution layers, flatten layers, and dense layers, with a filter size of 2, depth of 4, and 4 qubits, trained over 10 epochs. Two models were developed: a binary classification model distinguishing tumor presence and a multiclass classification model categorizing tumor types. The binary model achieved 88% accuracy, improving to 89% after data balancing, while the multiclass model achieved 52% accuracy, increasing to 62% after oversampling. Despite strong binary classification performance, the multiclass model faced challenges due to dataset complexity and quantum circuit limitations. These findings suggest that QCNNs hold promise for medical imaging applications, particularly in binary classification. However, further refinements, including optimized quantum circuit architectures and hybrid classical-quantum approaches, are necessary to enhance multiclass classification accuracy and improve QCNN applicability in clinical settings.

physics.med-ph↗

Dosimetric Evaluation of CT-to-RED Calibration Curves on Dosimetric Accuracy in Brain Radiotherapy

Accurate radiotherapy dose calculation depends on converting CT Hounsfield Units (HU) to relative electron density (RED) using calibration curves. This study compared three different CT-to-RED calibration curves-two derived from physical phantoms (CIRS 062M and Catphan 604) and one default curve from the Monaco treatment planning system (TPS) by recalculating ten brain tumor VMAT plans. The analysis showed that using the default TPS curve led to dose overestimation (by 3 5 for target volumes and 2 4 for some critical organs) compared to the CIRS phantom-derived curve, which was the most accurate. The Catphan curve had intermediate results. The findings highlight that the choice of calibration curve significantly affects dose accuracy in brain radiotherapy, and site-specific, phantom-based calibration should be prioritized to improve treatment precision and safety.

physics.med-ph↗