Roadmap towards the redefinition of the second

This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the necessary level of uncertainty are discussed. In addition, the mandatory criteria to be achieved before redefinition and their current fulfilment level, together with the redefinition options based on a single or on a set of transitions are described.

physics.atom-ph↗

AC Stark Shifts of Dark Resonances Probed with Ramsey Spectroscopy

The off-resonant AC Stark shift for coherent population trapping (CPT) resonances probed with Ramsey spectroscopy is investigated experimentally and theoretically. Measurements with laser-cooled $^{87}$Rb atoms show excellent quantitative agreement with a simple theory. The shift depends on the relative intensity of the two CPT light fields, but depends only weakly on the total intensity. Since the origin of the shift is through couplings of the interrogation light to off-resonant excited state hyperfine levels, the size and sign of the shift depend on the specific interrogation scheme. However, the simple theory shows that for several commonly used interrogation schemes the off-resonant shift goes to zero at specific values of this relative intensity.

physics.atom-ph↗

Universal methods for suppressing the light shift in atomic clocks using power modulation

We show that the light shift in atomic clocks can be suppressed using time variation of the interrogation field intensity. By measuring the clock output at two intensity levels, error signals can be generated that simultaneously stabilize a local oscillator to an atomic transition and correct for the shift of this transition caused by the interrogating optical field. These methods are suitable for optical clocks using one- and two-photon transitions, as well as for microwave clocks based on coherent population trapping or direct interrogation. The proposed methods can be widely used both for high-precision scientific instruments and for a wide range of commercial clocks, including chip-scale atomic clocks.

physics.atom-ph↗

Optical pumping, decay rates and light shifts of cold-atom dark states

Coherent dark states in atoms, created by simultaneous interaction of two coherent light fields with a 3-level system, are of prime importance in quantum state manipulation. They are used extensively in quantum sensing and quantum information applications to build atomic clocks, magnetometers, atomic interferometers and more. Here we study the formation and decay of coherent dark-states in an ensemble of laser-cooled free-falling atoms. We measure the optical-pumping rate into the dark-state in the $σ^+-σ^-$ polarization configuration. We find that the pumping rate is linear with the optical field intensity, but about an order-of-magnitude slower than the rate predicted by the commonly used, but simplistic, three-level analytic formula. Using a numerical model we demonstrate that this discrepancy is due to the multi-level Zeeman manifold. Taking into account the slower pumping rate we explain quantitatively the relation between the light-shift and the duration of pumping into dark-state in Ramsey spectroscopy. We also measure the decay of the dark-state coherence and find that in our apparatus it is dominated by the mechanical motion of the atoms out of the probing region, while the atomic decoherence is negligible.

physics.atom-ph↗

Dynamic characterization of an alkali-ion battery as a source for laser-cooled atoms

We investigate a solid-state, reversible, alkali-ion battery (AIB) capable of regulating the density of alkali atoms in a vacuum system used for the production of laser-cooled atoms. The cold-atom sample can be used with in-vacuum chronoamperometry as a diagnostic for the voltage-controlled electrochemical reaction that sources or sinks alkali atoms into the vapor. In a combined reaction-diffusion-limited regime, we show that the number of laser-cooled atoms in a magneto-optical trap can be increased both by initially loading the AIB from the vapor for longer, and by using higher voltages across the AIB when atoms are subsequently sourced back into the vapor. The time constants associated with the change in atom number in response to a change in AIB voltage are in the range of 0.5 s - 40 s. The AIB alkali reservoir is demonstrated to survive oxidization during atmospheric exposure, simplifying reservoir loading prior to vacuum implementation as a replacement for traditional resistively-heated dispensers. The AIB capabilities may provide an improved atom number stability in next-generation atomic clocks and sensors, while also facilitating fast loading and increased interrogation times.

physics.atom-ph↗

Reduction of light shifts in Ramsey spectroscopy with a combined error signal

Light-induced frequency shifts can be a key limiting contribution to the mid and long-term frequency instability in atomic clocks. In this letter, we demonstrate the experimental implementation of the combined error signal interrogation protocol to a cold-atom clock based on coherent population trapping (CPT) and Ramsey spectroscopy. The method uses a single error signal that results from the normalized combination of two error signals extracted from two Ramsey sequences of different dark periods. The single combined error signal is used to stabilize the atomic clock frequency. Compared to the standard Ramsey-CPT interrogation, this method reduces the clock frequency sensitivity to light-shift variations by more than one order of magnitude. This method can be applied in various kinds of Ramsey-based atomic clocks, sensors and instruments.

physics.atom-ph↗

A magneto-optic trap using a reversible, solid-state alkali-metal source

We demonstrate a novel way to form and deplete a vapor-cell magneto-optic trap (MOT) using a reversible, solid-state alkali-metal source (AMS) via an applied polarized voltage. Using ~100 mW of electrical power, a trapped-atom number of 5x10^6 has been achieved starting from near zero and the timescales of the MOT formation and depletion of ~1 s. This fast, reversible, and low power alkali-atom source is desirable in both tabletop and portable cold-atom systems. The core technology of this device should translate readily to other alkali and alkaline-earth elements that could find a wide range of uses in cold-atom systems and instruments.

physics.atom-ph↗

Ramsey Spectroscopy with Displaced Frequency Jumps

Sophisticated Ramsey-based interrogation protocols using composite laser pulse sequences have been recently proposed to provide next-generation high-precision atomic clocks with a near perfect elimination of frequency shifts induced during the atom-probing field interaction. We propose here a simple alternative approach to the auto-balanced Ramsey (ABR) interrogation protocol and demonstrate its application to a cold-atom microwave clock based on coherent population trapping. The main originality of the method, based on two consecutive Ramsey sequences with different dark periods, is to sample the central Ramsey fringes with frequency-jumps finely-adjusted by an additional frequency-displacement concomitant parameter, scaling as the inverse of the dark-period. The advantage of this displaced frequency-jumps Ramsey (DFJR) method is that the local oscillator frequency is used as a single physical variable to control both servo loops of the sequence, simplifying its implementation and avoiding noise associated with controlling the LO phase. Compared to the usual Ramsey-CPT technique, the DFJR scheme reduces the sensitivity of the clock frequency to variations of the CPT sideband ratio and to the one-photon laser detuning by more than an order of magnitude. This simple method could be applied in a wide variety of Ramsey-spectroscopy based applications including frequency metrology with CPT-based and optical atomic clocks, mass spectrometry, and precision spectroscopy.

physics.atom-ph↗

Combined error signal in Ramsey spectroscopy of clock transitions

We have developed a universal method to form the reference signal for the stabilization of arbitrary atomic clocks based on Ramsey spectroscopy. Our approach uses an interrogation scheme of the atomic system with two different Ramsey periods and a specially constructed combined error signal (CES) computed by subtracting two error signals with the appropriate calibration factor. CES spectroscopy allows for perfect elimination of probe-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors and other imperfections of the interrogation procedure. The method is simpler than recently developed auto-balanced Ramsey spectroscopy techniques [Ch. Sanner, et al., Phys. Rev. Lett. 120, 053602 (2018); V. I. Yudin, et al., Phys. Rev. Appl. 9, 054034 (2018)], because it uses a single error signal that feeds back on the clock frequency. CES universal technique can be applied to many applications of precision spectroscopy.

physics.atom-ph↗

Generalized auto-balanced Ramsey spectroscopy of clock transitions

When performing precision measurements, the quantity being measured is often perturbed by the measurement process itself. This includes precision frequency measurements for atomic clock applications carried out with Ramsey spectroscopy. With the aim of eliminating probe-induced perturbations, a method of generalized auto-balanced Ramsey spectroscopy (GABRS) is presented and rigorously substantiated. Here, the usual local oscillator frequency control loop is augmented with a second control loop derived from secondary Ramsey sequences interspersed with the primary sequences and with a different Ramsey period. This second loop feeds back to a secondary clock variable and ultimately compensates for the perturbation of the clock frequency caused by the measurements in the first loop. We show that such a two-loop scheme can lead to perfect compensation of measurement-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors that are typical of other hyper-Ramsey schemes. Several variants of GABRS are explored based on different secondary variables including added relative phase shifts between Ramsey pulses, external frequency-step compensation, and variable second-pulse duration. We demonstrate that a universal anti-symmetric error signal, and hence perfect compensation at finite modulation amplitude, is generated only if an additional frequency-step applied during both Ramsey pulses is used as the concomitant variable parameter. This universal technique can be applied to the fields of atomic clocks, high-resolution molecular spectroscopy, magnetically induced and two-photon probing schemes, Ramsey-type mass spectrometry, and to the field of precision measurements. Some variants of GABRS can also be applied for rf atomic clocks using CPT-based Ramsey spectroscopy of the two-photon dark resonance.

physics.atom-ph↗

Nuclear quadrupole resonances in compact vapor cells: the crossover from the NMR to the NQR interaction regimes

We present the first experimental study that maps the transformation of nuclear quadrupole resonances from the pure nuclear quadrupole regime to the quadrupole-perturbed Zeeman regime. The transformation presents an interesting quantum-mechanical problem, since the quantization axis changes from being aligned along the axis of the electric-field gradient tensor to being aligned along the magnetic field. We achieve large nuclear quadrupole shifts for I = 3/2 131-Xe by using a 1 mm^3 cubic cell with walls of different materials. When the magnetic and quadrupolar interactions are of comparable size, perturbation theory is not suitable for calculating the transition energies. Rather than use perturbation theory, we compare our data to theoretical calculations using a Liouvillian approach and find excellent agreement.

quant-ph↗

Very high precision bound state spectroscopy near a $^{85}$Rb Feshbach resonance

We precisely measured the binding energy of a molecular state near the Feshbach resonance in a $^{85}$Rb Bose-Einstein condensate (BEC). Rapid magnetic field pulses induced coherent atom-molecule oscillations in the BEC. We measured the oscillation frequency as a function of B-field and fit the data to a coupled-channels model. Our analysis constrained the Feshbach resonance position [155.041(18) G], width [10.71(2) G], and background scattering length [-443(3) a$_0$] and yielded new values for $v_{DS}$, $v_{DT}$, and $C_6$. These results improved our estimate for the stability condition of an attractive BEC. We also found evidence for a mean-field shift to the binding energy.

cond-mat.stat-mech↗

Microscopic Dynamics in a Strongly Interacting Bose-Einstein Condensate

An initially stable 85Rb Bose-Einstein condensate (BEC) was subjected to a carefully controlled magnetic field pulse in the vicinity of a Feshbach resonance. This pulse probed the strongly interacting regime for the condensate, with calculated values for the diluteness parameter (na^3) ranging from 0.01 to 0.5. The field pulse was observed to cause loss of atoms from the condensate on remarkably short time scales (>=10 microsec). The dependence of this loss on magnetic field pulse shape and amplitude was measured. For triangular pulses shorter than 1 ms, decreasing the pulse length actually increased the loss, until extremely short time scales (a few tens of microseconds) were reached. Such time scales and dependencies are very different from those expected in traditional condensate inelastic loss processes, suggesting the presence of new microscopic BEC physics.

cond-mat.stat-mech↗

Improved Characterization of Elastic Scattering Near a Feshbach Resonance in 85Rb

We report extentions and corrections to the measurement of the Feshbach resonance in 85Rb cold atom collisions reported earlier [J. L. Roberts et al., Phys. Rev. Lett. 81, 5109 (1998)]. In addition to a better determination of the position of the resonance peak (154.9(4) gauss) and its width (11.0(4) gauss), improvements in our techniques now allow the measurement of the absolute size of the elastic scattering rate. This provides a new measure of the s-wave scasttering length as a function of magnetic field near the Feshbach resonance and contrains the Rb-Rb interaction potential.

physics.atom-ph↗

Controlled Collapse of a Bose-Einstein Condensate

The point of instability of a Bose-Einstein Condensate (BEC) due to attractive interactions was studied. Stable 85-Rb BECs were created and then caused to collapse by slowly changing the atom-atom interaction from repulsive to attractive using a Feshbach resonance. At a critical value, an abrupt transition was observed in which atoms were ejected from the condensate. By measuring the onset of this transition as a funstion of number and attractive interactions strength, we determined the stability condition to be N|a|/(aho)=0.461(12)(54), slightly lower than the predicted value of 0.574.