Searcharxiv⌕ Search

arXiv subjects

E. Aprile

Publications and source records attributed to E. Aprile.

At least 145 records · Page 8Linked to original sources

A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during the 2000 Balloon Flight Campaign

LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time projection chamber. One of the most relevant figures of merit for a Compton telescope is the detection efficiency for \g-rays, which depends on diverse contributions such as detector geometry and passive materials, trigger efficiency, dead time, etc. A detailed study of the efficiency of the LXeGRIT instrument, based both on laboratory measurements and Monte Carlo simulations, is presented in this paper.

physics.ins-det↗

3D Position Sensitive XeTPC for Dark Matter Search

The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.

astro-ph↗

Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon

Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV gamma-ray line from Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best achievable energy resolution, by removing the instrumental fluctuations, from liquid xenon scintillation light is estimated to be around 6-8% (sigma) for gamma-ray with energy between 662 keV and 122 keV.

physics.ins-det↗

Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment

We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber prototypes, developed for the XENON Dark Matter project. We find that the charge yield increases with decreasing recoil energy, and exhibits only a weak field dependence. These results are a first demonstration of the capability of dual phase xenon detectors to discriminate between electron and nuclear recoils, a key requirement for a sensitive dark matter search at recoil energies down to 20 keV.

astro-ph↗

Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils

Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important for determining the sensitivity of LXe direct detection experiments. Here we report on new measurements of the scintillation yield of Xe recoils with kinetic energy as low as 10 keV. The dependence of the scintillation yield on applied electric field was also measured in the range of 0 to 4 kV/cm. Results are in good agreement with recent theoretical predictions that take into account the effect of biexcitonic collisions in addition to the nuclear quenching effect.

astro-ph↗

Performance of a Large Area Avalanche Photodiode in a Liquid Xenon Ionization and Scintillation Chamber

Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric field is 7.5%(sigma) for 976 keV internal conversion electrons from Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector used for these measurements was also operated as a gridded ionization chamber to measure the charge yield. We confirm that using a LAAPD in LXe does not introduce impurities which inhibit the drifting of free electrons.

physics.ins-det↗

Detection of liquid xenon scintillation light with a Silicon Photomultiplier

We have studied the feasibility of a silicon photomultiplier (SiPM) to detect liquid xenon (LXe) scintillation light. The SiPM was operated inside a small volume of pure LXe, at -95 degree Celsius, irradiated with an internal Am-241 alpha source. The gain of the SiPM at this temperature was estimated to be 1.8 x 10^6 with bias voltage at 52 V. Based on the geometry of the setup, the quantum efficiency of the SiPM was estimated to be 22% at the Xe wavelength of 178 nm. The low excess noise factor, high single photoelectron detection efficiency, and low bias voltage of SiPMs make them attractive alternative UV photon detection devices to photomultiplier tubes (PMTs) for liquid xenon detectors, especially for experiments requiring a very low energy detection threshold, such as neutralino dark matter searches.

physics.ins-det↗

The XENON Dark Matter Search Experiment

The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to 16keV energy, via simultaneous detection of the ionization, through secondary scintillation in the gas, and primary scintillation in the liquid. Thedistinct ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or neutrons), and for electron recoils from background, iskey to the event-by-event discrimination capability of XENON. A dual phase xenon prototype has been realized and is currently being tested, along with otherprototypes dedicated to other measurements relevant to the XENON program. As part of the R&D phase, we will realize and move underground a first XENON module (XENON10) with at least 10 kg fiducial mass to measure the background rejection capability and to optimize the conditions for continuous and stable detector operation underground. We present some of the results from the ongoing R&D and summarize the expected performance of the 10 kg experiment, from MonteCarlo simulations. The main design features of the 100 kg detector unit(XENON100), with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will also be presented.

astro-ph↗

Detection of partial polarization in Compton scattered photons

It has been recently proposed (Boggs, Nucl. Instr. and Meth. A 503 (2003) 562), to use polarization of Compton scattered gamma-rays to improve the imaging performance of Compton telescopes. Building upon that work, we detected the aforementioned polarization in a sample of 1.836 MeV gamma-rays from the LXeGRIT Compton telescope. Here we present the measurement, together with detector oriented considerations on the application of the principle to a realistic Compton telescope.

hep-ex↗

The LXeGRIT Compton Telescope Prototype: Current Status and Future Prospects

LXeGRIT is the first prototype of a novel concept of Compton telescope, based on the complete 3-dimensional reconstruction of the sequence of interactions of individual gamma rays in one position sensitive detector. This balloon-borne telescope consists of an unshielded time projection chamber with an active volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV PMTs detect the fast xenon scintillation light signal, providing the event trigger. 124 wires and 4 anodes detect the ionization signals, providing the event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT has been extensively tested both in the laboratory and at balloon altitude, and its response in the MeV region has been thoroughly characterized. Here we summarize some of the results on pre-flight calibration, event reconstruction techniques, and performance during a 27 hour balloon flight on October 4 -- 5. We further present briefly the on-going efforts directed to improve the performance of this prototype towards the requirements for a base module of a next-generation Compton telescope.

astro-ph↗

On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon Flight

LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC), sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position sensitive detector, gamma rays with at least two interactions in the sensitive volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope. Gamma-rays with a single interaction cannot be imaged and constitute a background which can be easily identified and rejected. Charged particles and localized beta-particles background is also easily suppressed based on the TPC localization capability with millimeter resolution. A measurement of the total gamma-ray background rate in near space conditions and the background rejection power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program. We present here a preliminary analysis addressing this question, based on balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield. Single site events and charged particles were mostly rejected on-line at the first and second trigger level. The remaining count rate of single-site \g-ray events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with that expected from atmospheric and diffuse gamma-ray background, taking into account the instrument mass model and response.

astro-ph↗

XENON: a 1 tonne Liquid Xenon Experiment for a Sensitive Dark Matter Search

XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of ionization and scintillation signals in liquid xenon, with the goal of extracting as much information as possible on an event-by-event basis, while maintaining most of the target active. XENON is expected to have effective and redundant background identification and discrimination power, higher than 99.5%, and to achieve a very low threshold, on the order of 4 keV visible recoil energy. Based on this expectation and the 1-tonne mass of active xenon, we project a sensitivity of 0.0001 events/kg/day, after 3 yr operation in an appropriate underground location. The XENON experiment has been recently proposed to the National Science Foundation (NSF) for an initial development phase leading to the development of the 100 kg unit module.

astro-ph↗

Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)

LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional spatial resolution as measured during pre-flight calibration experiments, are $ΔE_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively. The detection efficiency for Compton events varies between 1.5% and 4% depending on energy and event selection. We describe the instrument as flown on May 7, 1999 and review its overall performance at balloon altitude. The launch occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was terminated about 9 hours later. The Crab was in the instrument FOV for a few hours. Analysis of these data is in progress.

astro-ph↗

Performance of the Light Trigger System in the Liquid Xenon Gamma-Ray Telescope LXeGRIT

LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber with charge and light readout. The energy and direction of an incident gamma-ray is reconstructed from the three-dimensional locations and energy deposits of individual interactions taking place in the homogeneous detector volume. While the charge signals provide energy information and X-Y positions, the fast xenon scintillation light signal is used to trigger the detector. The drift time measurement, referred to the time of the trigger signal, gives the Z-position with the known drift velocity. The light is detected by four UV-sensitive photomultiplier tubes (PMTs). The logical OR of the PMT signals triggers the data acquisition system with an efficiency which depends on the event energy and location, as well as on the discriminator thresholds used on the individual PMTs. Results from experiments with a tagged 22Na source give the spatial distribution of the light trigger efficiency for 511 keV gamma-rays. When averaged over the whole sensitive volume amd all PMTs, the trigger efficiency is 47% or 40% for two discriminator windows used during the LXeGRIT balloon flight of 1999. These values are strongly affected by the different sensitivity of each PMT. The corresponding average efficiency at 511 keV for the best of the four PMTs is in fact 63%, and approaches 100% for interactions taking place in a small volume right above the PMT.

astro-ph↗

An Upgraded Data Acquisition System for the Balloon-Borne Liquid Xenon Gamma-Ray Telescope LXeGRIT

LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber (LXe-TPC) with charge and light readout. The first balloon flights in 1997 revealed limitations of the trigger electronics and the data acquisition (DAQ) system, leading to their upgrade. New electronics was developed to handle the xenon scintillation light trigger. The original processor module was replaced by a commercial VME processor. The telemetry rate was doubled to 2 x 500 kbps and onboard data storage on hard disks was implemented. Relying on a robust real-time operating system, the new DAQ software adopts an object oriented design to implement the diverse tasks of trigger handling, data selection, transmission, and storage, as well as DAQ control and monitor functions. The new systems performed well during two flights in Spring 1999 and Fall 2000. In the 2000 flight, the DAQ system was able to handle 300-350 triggers/s out of a total of about 650 Hz, including charged particles.

astro-ph↗

Compton scattering sequence reconstruction algorithm for the liquid xenon gamma-ray imaging telescope (LXeGRIT)

The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in which the three-dimensional location and energy deposit of individual \g -ray interactions are accurately measured in one homogeneous volume. To determine the \g -ray initial direction (Compton imaging), as well as to reject background, the correct sequence of interactions has to be determined. Here we report the development and optimization of an algorithm to reconstruct the Compton scattering sequence and show its performance on Monte Carlo events and LXeGRIT data.

astro-ph↗

Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)

LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of 0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual \g -ray interactions within the sensitive volume. The TPC has been characterized with repeated measurements of its spectral and Compton imaging response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be. The detector shows a linear response to \g -rays in the energy range 511 keV -4.4 MeV, with an energy resolution (FWHM) of $ ΔE/E=8.8% \: \sqrt{1\MeV /E}$. Compton imaging of \yt \g -ray events with two detected interactions is consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.

astro-ph↗

Measurement of neutrino oscillations by means of a high density detector on the atmospheric neutrino beam

A high-density calorimeter, consisting of magnetized iron planes interleaved by RPCs, as tracking and timing devices, is a good candidate for a next generation experiment on atmospheric neutrinos. With 34 kt of mass and in four years of data taking, this experiment will be sensitive to $ν_μ\to ν_x$ oscillation with $Δm^2 > 6 \times 10^{-5}$ and mixing near to maximal and fully cover the region of oscillation parameters suggested by Super-Kamiokande results. Moreover, the experimental method will enable to measure the oscillation parameters from the modulation of the L/E spectrum ($ν_μ$ disappearance). For $Δm^2 > 3 \times 10^{-3}$ eV$^2$, this experiment can also establish whether the oscillation occurs into a tau or a sterile neutrino, by looking for an excess of muon-less events at high energies produced by upward-going tau neutrinos ($ν_τ$ appearance).

hep-ex↗