SearcharxivSearch

arXiv subjects

E. B. Iverson

Publications and source records attributed to E. B. Iverson.

12 recordsLinked to original sources

The 3He(\vec n,p)3H parity-conserving asymmetry

Recently, the n$^3$He collaboration reported a measurement of the parity-violating (PV) proton directional asymmetry $A_{\mathrm {PV}} = (1.55\pm 0.97~\mathrm {(st\ at)} \pm 0.24~\mathrm {(sys)})\times 10^{-8}$ in the capture reaction of ${}^3$He$(\vec {n},{\mathrm p}){}^3$H at meV incident neutron energies. The result increased the limited inventory of precisely measured and calculable PV observables in few-body systems required to further understand the structure of hadronic weak interaction. In this letter, we report the experimental and theoretical investigation of a parity conserving (PC) asymmetry $A_{\mathrm {PC}}$ in the same reaction (the first ever measured PC observable at meV neutron energies). As a result of S- and P-wave mixing in the reaction, the $A_{\mathrm {PC}}$ is inversely proportional to the neutron wavelength $λ$. The experimental value is $(λ\times A_{\mathrm {PC}})\equivβ= (-1.97 \pm 0.28~\mathrm{(stat)}\pm 0.12~\mathrm{(sys)}) \times 10^{-6}$ Amstrongs. We present results for a theoretical analysis of this reaction by solving the four-body scattering problem within the hyperspherical harmonic method. We find that in the ${}^3$He$(\vec {n},{\mathrm p}){}^3$H reaction, $A_{\mathrm {PC}}$ depends critically on the energy and width of the close $0^-$ resonant state of ${}^4$He, resulting in a large sensitivity to the spin-orbit components of the nucleon-nucleon force and even to the three-nucleon force. The analysis of the accurately measured $A_{\mathrm {PC}}$ and $A_{\mathrm {PV}}$ using the same few-body theoretical models gives essential information needed to interpret the PV asymmetry in the ${}^3$He$(\vec {n}, {\mathrm p}){}^3$H reaction.

nucl-ex

Measurement of the Parity-Odd Angular Distribution of Gamma Rays From Polarized Neutron Capture on $^{35}$Cl

We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the ${}^{35}$Cl nucleus, one parity-odd correlation proportional to $\vec{s_{n}} \cdot \vec{k_γ}$ and one parity-even correlation proportional to $\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}$. A parity violating asymmetry can appear in this reaction due to the weak nucleon-nucleon (NN) interaction which mixes opposite parity S and P-wave levels in the excited compound $^{36}$Cl nucleus formed upon slow neutron capture. If parity-violating (PV) and parity-conserving (PC) terms both exist, the measured differential cross section can be related to them via $\frac{dσ}{dΩ}\propto1+A_{γ, PV}\cosθ+A_{γ,PC}\sinθ$. The PV and PC asymmetries for energy-weighted gamma cascade angular distributions for polarized slow neutron capture on $^{35}$Cl averaged over the neutron energies from 2.27~meV to 9.53~meV were measured to be $A_{γ,PV}=(-23.9\pm0.7)\times 10^{-6}$ and $A_{γ,PC}=(0.1\pm0.7)\times 10^{-6}$. These results are consistent with previous experimental results. Systematic errors were quantified and shown to be small compared to the statistical error. These asymmetries in the angular distributions of the gamma rays emitted from the capture of polarized neutrons in $^{35}$Cl were used to verify the operation and data analysis procedures for the NPDGamma experiment which measured the parity-odd asymmetry in the angular distribution of gammas from polarized slow neutron capture on protons.

nucl-ex

Experimental Search for Neutron to Mirror Neutron Oscillations as an Explanation of the Neutron Lifetime Anomaly

An unexplained $>4\,σ$ discrepancy persists between "beam" and "bottle" measurements of the neutron lifetime. A new model proposed that conversions of neutrons $n$ into mirror neutrons $n'$, part of a dark mirror sector, can increase the apparent neutron lifetime by $1\%$ via a small mass splitting $Δ{m}$ between $n$ and $n'$ inside the 4.6 T magnetic field of the National Institute of Standards and Technology Beam Lifetime experiment. A search for neutron conversions in a 6.6 T magnetic field was performed at the Spallation Neutron Source which excludes this explanation for the neutron lifetime discrepancy.

nucl-ex

New search for mirror neutron regeneration

The possibility of relatively fast neutron oscillations into a mirror neutron state is not excluded experimentally when a mirror magnetic field is considered. Direct searches for the disappearance of neutrons into mirror neutrons in a controlled magnetic field have previously been performed using ultracold neutrons, with some anomalous results reported. We describe a technique using cold neutrons to perform a disappearance and regeneration search, which would allow us to unambiguously identify a possible oscillation signal. An experiment using the existing General Purpose-Small Angle Neutron Scattering instrument at the High Flux Isotope Reactor at Oak Ridge National Laboratory will have the sensitivity to fully explore the parameter space of prior ultracold neutron searches and confirm or refute previous claims of observation. This instrument can also conclusively test the validity of recently suggested oscillation-based explanations for the neutron lifetime anomaly.

physics.ins-det

First Observation of $P$-odd $γ$ Asymmetry in Polarized Neutron Capture on Hydrogen

We report the first observation of the parity-violating 2.2 MeV gamma-ray asymmetry $A^{np}_γ$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. $A^{np}_γ$ isolates the $ΔI=1$, \mbox{$^{3}S_{1}\rightarrow {^{3}P_{1}}$} component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless EFT. We measured $A^{np}_γ= [-3.0 \pm 1.4 (stat) \pm 0.2 (sys)]\times 10^{-8}$, which implies a DDH weak $πNN$ coupling of $h_π^{1} = [2.6 \pm 1.2(stat) \pm 0.2(sys)] \times 10^{-7}$ and a pionless EFT constant of $C^{^{3}S_{1}\rightarrow ^{3}P_{1}}/C_{0}=[-7.4 \pm 3.5 (stat) \pm 0.5 (sys)] \times 10^{-11}$ MeV$^{-1}$. We describe the experiment, data analysis, systematic uncertainties, and the implications of the result.

nucl-ex

COHERENT Collaboration data release from the first observation of coherent elastic neutrino-nucleus scattering

This release includes data and information necessary to perform independent analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294 [nucl-ex]. Data is shared in a binned, text-based format, including both "signal" and "background" regions, so that counts and associated uncertainties can be quantitatively calculated for the purpose of separate analyses. This document describes the included information and its format, offering some guidance on use of the data. Accompanying code examples show basic interaction with the data using Python.

nucl-ex

COHERENT 2018 at the Spallation Neutron Source

The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.

physics.ins-det

New Search for Mirror Neutrons at HFIR

The theory of mirror matter predicts a hidden sector made up of a copy of the Standard Model particles and interactions but with opposite parity. If mirror matter interacts with ordinary matter, there could be experimentally accessible implications in the form of neutral particle oscillations. Direct searches for neutron oscillations into mirror neutrons in a controlled magnetic field have previously been performed using ultracold neutrons in storage/disappearance measurements, with some inconclusive results consistent with characteristic oscillation time of $τ$$\sim$10~s. Here we describe a proposed disappearance and regeneration experiment in which the neutron oscillates to and from a mirror neutron state. An experiment performed using the existing General Purpose-Small Angle Neutron Scattering instrument at the High Flux Isotope Reactor at Oak Ridge National Laboratory could have the sensitivity to exclude up to $τ$$<$15~s in 1 week of beamtime and at low cost.

hep-ex

Observation of Coherent Elastic Neutrino-Nucleus Scattering

The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross-section is the largest by far of all low-energy neutrino couplings. This mode of interaction provides new opportunities to study neutrino properties, and leads to a miniaturization of detector size, with potential technological applications. We observe this process at a 6.7-sigma confidence level, using a low-background, 14.6-kg CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the Standard Model for this process, are observed in high signal-to-background conditions. Improved constraints on non-standard neutrino interactions with quarks are derived from this initial dataset.

nucl-ex

The COHERENT Experiment at the Spallation Neutron Source

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the $N^2$ dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

physics.ins-det

Fundamental Neutron Physics Beamline at the Spallation Neutron Source at ORNL

We describe the Fundamental Neutron Physics Beamline (FnPB) facility located at the Spallation Neutron Source at Oak Ridge National Laboratory. The FnPB was designed for the conduct of experiments that investigate scientific issues in nuclear physics, particle physics, astrophysics and cosmology using a pulsed slow neutron beam. We present a detailed description of the design philosophy, beamline components, and measured fluxes of the polychromatic and monochromatic beams.

physics.ins-det

The new Cold Neutron Chopper Spectrometer at the Spallation Neutron Source - Design and Performance

The design and performance of the new Cold Neutron Chopper Spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct geometry inelastic time-of-flight spectrometer, designed to cover essentially the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM2, AMATERAS at J-PARC, PHAROS at LANSCE and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

physics.ins-det