SearcharxivSearch

arXiv subjects

E. Benkler

Publications and source records attributed to E. Benkler.

13 recordsLinked to original sources

Transportable strontium lattice clock with $4 \times 10^{-19}$ blackbody radiation shift uncertainty

We describe a transportable optical lattice clock based on the $^1\mathrm{S}_0 \rightarrow {^3\mathrm{P}_0}$ transition of lattice-trapped $^{87}$Sr atoms with a total systematic uncertainty of $2.1 \times 10^{-18}$. The blackbody radiation shift, which is the leading systematic effect in many strontium lattice clocks, is controlled at the level of $4.0 \times 10^{-19}$, as the atoms are interrogated inside a well-characterised, cold thermal shield. Using a transportable clock laser, the clock reaches a frequency instability of about $5 \times 10^{-16}/\sqrt{\tau/\mathrm{s}}$, which enables fast reevaluations of systematic effects. By comparing this clock to the primary caesium fountain clocks CSF1 and CSF2 at Physikalisch-Technische Bundesanstalt, we measure the clock transition frequency with a fractional uncertainty of $1.9\times 10^{-16}$, in agreement with previous results. The clock was successfully transported and operated at different locations. It holds the potential to be used for geodetic measurements with centimetre-level or better height resolution and for accurate inter-institute frequency comparisons.

physics.atom-ph

High-accuracy multi-ion spectroscopy with mixed-species Coulomb crystals

Multi-ion optical clocks offer the possibility of overcoming the low signal-to-noise ratio of single-ion clocks, while still providing low systematic uncertainties. We present simultaneous spectroscopy of up to four ${}^{115}$In${}^+$ clock ions in a linear Coulomb crystal, sympathetically cooled with ${}^{172}$Yb${}^+$ ions. In first clock comparisons, we see agreement below $1\times10^{-17}$ with results obtained using a single In${}^+$ ion, for which we have evaluated the systematic uncertainty to be $2.5\times10^{-18}$. Operation with four clock ions reduces the instability from $1.6\times10^{-15}/\sqrt{t/(1\;\mathrm{s})}$ to $9.2\times10^{-16}/\sqrt{t/(1\;\mathrm{s})}$. We derive a model for decay-related dead time during state preparation, which matches the observed scaling of instability with clock ion number $N$, and indicates that $1/\sqrt{N}$ scaling can be achieved with the addition of a repump laser.

physics.atom-ph

Nonlinear calcium King plot constrains new bosons and nuclear properties

Nonlinearities in King plots (KP) of isotope shifts (IS) can reveal the existence of beyond-Standard-Model (BSM) interactions that couple electrons and neutrons. However, it is crucial to distinguish higher-order Standard Model (SM) effects from BSM physics. We measure the IS of the transitions ${{}^{3}P_{0}~\rightarrow~{}^{3}P_{1}}$ in $\mathrm{Ca}^{14+}$ and ${{}^{2}S_{1/2} \rightarrow {}^{2}D_{5/2}}$ in $\mathrm{Ca}^{+}$ with sub-Hz precision as well as the nuclear mass ratios with relative uncertainties below $4\times10^{-11}$ for the five stable, even isotopes of calcium (${}^{40,42,44,46,48}\mathrm{Ca}$). Combined, these measurements yield a calcium KP nonlinearity with a significance of $\sim 900 \sigma$. Precision calculations show that the nonlinearity cannot be fully accounted for by the expected largest higher-order SM effect, the second-order mass shift, and identify the little-studied nuclear polarization as the only remaining SM contribution that may be large enough to explain it. Despite the observed nonlinearity, we improve existing KP-based constraints on a hypothetical Yukawa interaction for most of the new boson masses between $10~\mathrm{eV/c^2}$ and $10^7~\mathrm{eV/c^2}$.

physics.atom-ph

$^{115}$In$^+$-$^{172}$Yb$^+$ Coulomb crystal clock with $2.5\times10^{-18}$ systematic uncertainty

We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3Yb$^+$ crystal, achieving a relative systematic uncertainty of $2.5\times10^{-18}$ and a relative frequency instability of $1.6\times10^{-15}/\sqrt{\tau/1\;\mathrm{s}}$. We report on absolute frequency measurements with an uncertainty of $1.3\times10^{-16}$ and optical frequency comparisons with clocks based on $^{171}$Yb$^+$ (E3) and $^{87}$Sr. With a fractional uncertainty of $4.4\times10^{-18}$, the former is - to our knowledge - the most accurate frequency ratio value reported to date. For the $^{115}$In$^+$/$^{87}$Sr ratio, we improve upon the best previous measurement by more than an order of magnitude. We also demonstrate operation with four $^{115}$In$^+$ clock ions, which reduces the instability to $9.2\times10^{-16}/\sqrt{\tau/1\;\mathrm{s}}$.

physics.atom-ph

Long-distance chronometric leveling with a portable optical clock

We have measured the geopotential difference between two locations separated by $457~\mathrm{km}$ by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of $3918.1(2.6)\,\mathrm{m^2 \, s^{-2}}$ agrees with an independent geodetic determination of $3915.88(0.30)\,\mathrm{m^2 \, s^{-2}}$. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of $27~\mathrm{cm}$ in height.

physics.atom-ph

Improved limits on the coupling of ultralight bosonic dark matter to photons from optical atomic clock comparisons

We present improved constraints on the coupling of ultralight bosonic dark matter to photons based on long-term measurements of two optical frequency ratios. In these optical clock comparisons, we relate the frequency of the ${}^2S_{1/2} (F=0)\leftrightarrow {}^2F_{7/2} (F=3)$ electric-octupole (E3) transition in $^{171}$Yb$^{+}$ to that of the ${}^2S_{1/2} (F=0)\leftrightarrow \,{}^2D_{3/2} (F=2)$ electric-quadrupole (E2) transition of the same ion, and to that of the ${}^1S_0\leftrightarrow\,{}^3P_0$ transition in $^{87}$Sr. Measurements of the first frequency ratio $\nu_\textrm{E3}/\nu_\textrm{E2}$ are performed via interleaved interrogation of both transitions in a single ion. The comparison of the single-ion clock based on the E3 transition with a strontium optical lattice clock yields the second frequency ratio $\nu_\textrm{E3}/\nu_\textrm{Sr}$. By constraining oscillations of the fine-structure constant $\alpha$ with these measurement results, we improve existing bounds on the scalar coupling $d_e$ of ultralight dark matter to photons for dark matter masses in the range of about $ 10^{-24}-10^{-17}\,\textrm{eV}/c^2$. These results constitute an improvement by more than an order of magnitude over previous investigations for most of this range. We also use the repeated measurements of $\nu_\textrm{E3}/\nu_\textrm{E2}$ to improve existing limits on a linear temporal drift of $\alpha$ and its coupling to gravity.

physics.atom-ph

Coherent laser spectroscopy of highly charged ions using quantum logic

Precision spectroscopy of atomic systems is an invaluable tool for the advancement of our understanding of fundamental interactions and symmetries. Recently, highly charged ions (HCI) have been proposed for sensitive tests of physics beyond the Standard Model and as candidates for high-accuracy atomic clocks. However, the implementation of these ideas has been hindered by the parts-per-million level spectroscopic accuracies achieved to date. Here, we cool a trapped HCI to the lowest reported temperatures, and introduce coherent laser spectroscopy on HCI with an eight orders of magnitude leap in precision. We probe the forbidden optical transition in $^{40}$Ar$^{13+}$ at 441 nm using quantum-logic spectroscopy and measure both its excited-state lifetime and $g$-factor. Our work ultimately unlocks the potential of HCI, a large, ubiquitous atomic class, for quantum information processing, novel frequency standards, and highly sensitive tests of fundamental physics, such as searching for dark matter candidates or violations of fundamental symmetries.

physics.atom-ph

Long term measurement of the $^{87}$Sr clock frequency at the limit of primary Cs clocks

We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of $429\:228\:004\:229\:873.00(0.07)$~Hz with $1.5\times10^{-16}$ fractional uncertainty, at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton--electron mass ratio $μ$, and confirms the limits on its temporal drift.

physics.atom-ph

Direct comparisons of European primary and secondary frequency standards via satellite techniques

We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.

physics.ins-det

Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks

We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.

astro-ph.CO

946-nm Nd:YAG digital-locked laser at $1.1\times10^{-16}$ in 1 s and transfer-locked to a cryogenic silicon cavity

We present a Nd:YAG ultra-stable laser system operating at 946 nm and demonstrate a fractional frequency instability of $1.1\times10^{-16}$ at 1 s by pre-stabilizing it to a 30 cm-long ULE cavity at room temperature. All key analog components have been replaced by FPGA-based digital electronics. To reach an instability below the $10^{-16}$ level, we transfer the stability of a 1542 nm laser stabilized to a cryogenic silicon cavity exhibiting a fractional frequency instability of $4\times10^{-17}$ at 1 s to the laser at 946 nm.

physics.optics

Manipulation and removal of defects in spontaneous optical patterns

Defects play an important role in a number of fields dealing with ordered structures. They are often described in terms of their topology, mutual interaction and their statistical characteristics. We demonstrate theoretically and experimentally the possibility of an active manipulation and removal of defects. We focus on the spontaneous formation of two-dimensional spatial structures in a nonlinear optical system, a liquid crystal light valve under single optical feedback. With increasing distance from threshold, the spontaneously formed hexagonal pattern becomes disordered and contains several defects. A scheme based on Fourier filtering allows us to remove defects and to restore spatial order. Starting without control, the controlled area is progressively expanded, such that defects are swept out of the active area.

nlin.PS

Tailoring the profile and interactions of optical localized structures

We experimentally demonstrate the broad tunability of the main features of optical localized structures (LS) in a nonlinear interferometer. By discussing how a single LS depends on the system spatial frequency bandwidth, we show that a modification of its tail leads to the possibility of tuning the interactions between LS pairs, and thus the equilibrium distances at which LS bound states form. This is in agreement with a general theoretical model describing weak interactions of LS in nonlinear dissipative systems.

nlin.PS