Modeling Light Signals Using Data from the First Pulsed Neutron Source Program at the DUNE Vertical Drift ColdBox Test Facility at CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN neutrino platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. A good agreement is found in the detected number of photoelectrons, with values below 650 photoelectrons in both data and simulation, for all four X-ARAPUCA photodetectors on the cathode in the LArTPC. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and MC. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

hep-ex

Cosmic Ray Measurements Using Charge and Light Readout in a Pixelated Liquid Argon Time Projection Chamber

Liquid argon time projection chambers have emerged as a competitive technology for detecting solar neutrinos. The SoLAr collaboration was formed to explore argon detectors with pixelated light and charge readout, aiming for high detection efficiency and improved energy resolution. Building on the success of an initial prototype, we present results obtained with a second SoLAr prototype (V2), a $30 \times 30 \times 30$ cm$^{3}$ time projection chamber operated in a cryostat containing several hundred kilograms of liquid argon. We report measurements of cosmic-ray muons using both tracking and calorimetry from light and charge sensors, and we highlight the improved performance achieved through combined charge and light reconstruction. These results demonstrate the promise of dual-readout detectors and motivate future prototyping efforts toward kiloton-scale facilities.

physics.ins-det

Cryogenic characterization of FBK NUV-HD-Cryo 3T SiPM sensors for the DUNE photon detection system

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment based in the USA and composed of a Near Detector (ND) complex at Fermi National Laboratory (FNAL), and a Far Detector (FD) complex located at the Sanford Underground Research Facility (SURF) $\sim$1300\,km distant. DUNE will study neutrino oscillations looking for unresolved issues of the Standard Model of particle physics (SM) such as CP violation in the leptonic sector, neutrino mass ordering and others, starting from the early 2030s. The FD, with a mass of $\sim$17\,kt, that will exploit both ionization and scintillation signals to detect neutrino interactions with Argon. Scintillating photons in LAr will be detected by the photon detection system (PDS) based on light collectors coupled to Silicon Photomultipliers (SiPMs). During a test campaign, different laboratories of the collaboration performed an investigation of the best SiPM candidates that fulfill the DUNE FD requirements. We identified two models of SiPM, produced by Hamamatsu Photonics K.K. (HPK) and Fondazione Bruno Kessler (FBK), respectively. In this paper, we focus on the FBK selected model showing its main features. We will describe the characterization protocol, the results at both room and cryogenic temperatures and the photon detection efficiency measurements.

physics.ins-det

Measurement of the X-ARAPUCA's Absolute Photon Detection Efficiency for the Deep Underground Neutrino Experiment's Vertical Drift Far Detector

The DUNE experiment will implement a photon detection system composed of X-ARAPUCA (XA) devices. These trap incoming VUV photons by internal reflection in a wavelength shifter light guide to be collected onto silicon photomultiplier arrays, sensitive to visible light. In the baseline design, dichroic filters are used to prevent photons from escaping. The configuration proposed for DUNE's Vertical Drift (VD) module has been characterised in liquid argon for the first time using dedicated cryogenic setups developed at CIEMAT and INFN Naples. Additionally, several alternative configurations, based on the design optimisation studies of an R&D campaign, have been evaluated. The results show an efficiency of up to 4.5$\pm$4~% at 4.5~V overvoltage, representing a significant improvement over previous XA implementations. Most notably, configurations without dichroic filters show an improvement of up to 18~%, attributed to transmittance losses in the dichroic filters.

physics.ins-det

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8$\times$8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 $\mu$m per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

physics.ins-det

The Stochastic Light Confinement of LiquidO

Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechanisms that are then propagated through transparent media to photosensors placed typically on the detector's periphery, sometimes up to tens of metres away. LiquidO is a new technique pioneering the use of opaque media to stochastically confine light around each energy deposition while collecting it with an array of fibres that thread the medium. This approach preserves topological event information otherwise lost in the conventional approach, enabling real-time imaging down to the MeV scale. Our article demonstrates LiquidO's imaging principle with a ten-litre prototype, revealing successful light confinement of 90% of the detected light within a 5 cm radius sphere, using a custom opaque scintillator with a scattering length on the order of a few millimetres. These high-resolution imaging capabilities unlock opportunities in fundamental physics research and applications beyond. The absolute amount of light detected is also studied, including possible data-driven extrapolations to LiquidO-based detectors beyond prototyping limitations. Additionally, LiquidO's timing capabilities are explored through its ability to distinguish Cherenkov light from a slow scintillator.

physics.ins-det

COCOA: a compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

astro-ph.IM

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

The Photon Detection System (PDS) of the first DUNE far detector (FD1) is composed of 6000 photon detection units, named X-ARAPUCA. The detection of the prompt light pulse generated by the particle energy release in liquid argon (LAr) will complement and boost the DUNE Liquid Argon Time Projection Chamber (LArTPC). It will improve the non-beam events tagging and enable at low energies the trigger and the calorimetry of the supernova neutrinos. The X-ARAPUCA unit is an assembly of several components. Its Photon Detection Efficiency (PDE) depends both on the design of the assembly, on the grade of the individual components and finally on their coupling. The X-ARAPUCA PDE is one of the leading parameters for the Photon Detection System sensitivity, that in turn determines the sensitivity of the DUNE for the detection of core-collapse supernova within the galaxy and for nucleon decay searches. In this work we present the final assessment of the absolute PDE of the FD1 X-ARAPUCA baseline design, measured in two laboratories with independent methods and setups. One hundred sixty units of these X-ARAPUCA devices have been deployed in the NP04 facility at the CERN Neutrino Platform, the 1:20 scale FD1 prototype, and will be operated during the year 2024. The assessed value of the PDE is a key parameter both in the NP04 and in the DUNE analysis and reconstruction studies.

physics.ins-det

Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos

The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity dominated by potassium (40K) and the decay chains of uranium (238U) and thorium (232Th). This radiogenic energy output is critical to planetary dynamics and must be accurately measured for a complete understanding of the overall heat budget and thermal history of the Earth. Detecting geoneutrinos remains the only direct probe to do so and constitutes a challenging objective in modern neutrino physics. In particular, the intriguing potassium geoneutrinos have never been observed and thus far have been considered impractical to measure. We propose here a novel approach for potassium geoneutrino detection using the unique antimatter signature of antineutrinos to reduce the otherwise overwhelming backgrounds to observing this rarest signal. The proposed detection framework relies on the innovative LiquidO detection technique to enable positron (e+) identification and antineutrino interactions with ideal isotope targets identified here for the first time. We also provide the complete experimental methodology to yield the first potassium geoneutrino discovery.

physics.geo-ph

The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector

The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98\% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.

hep-ex

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle {\theta}13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det

ProtoDUNE-DP Light Acquisition and Calibration Software

ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber operated at the CERN Neutrino Platform in 2019-2020 as a prototype of the Dual Phase concept for the DUNE Far Detector. The Photon Detection System (PDS) is based on 36 8-inch photo-multiplier tubes (PMTs) and allows triggering on the scintillation light signals produced by cosmic rays and other charged particles traversing the detector. The acquisition and calibration software specifically developed for the ProtoDUNE-DP PDS is described in this paper. This software controls the high-voltage power supplies, the calibration system, and the PDS DAQ. It has been developed with Qt Creator, and features different operation modes, and a graphical user interface. This software has already been validated and used during the ProtoDUNE-DP operation.

physics.ins-det

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

physics.ins-det

First testing of the Hamamatsu R5912-02Mod photomultiplier tube at 4-bar pressure and cryogenic temperature

The Hamamatsu R5912-02Mod photomultiplier tube (PMT) will be used in the DUNE dual-phase module, a 10-kton fiducial volume liquid-argon time-projection chamber, which is one of the four projected far-detector modules of the DUNE long-baseline neutrino experiment. In the DUNE dual-phase module, the liquid argon places high pressure on the photo-detectors located at the bottom of the 14-m cryostat. Four Hamamatsu R5912-02Mod PMTs were tested at 4-bar absolute pressure and cryogenic temperature (in liquid nitrogen) for the first time. No mechanical or electrical damage is reported, validating the use of this PMT model in the DUNE dual-phase module and in other large scale cryogenic liquid detectors. The differences observed in their behavior are expected for the change in the PMT operating temperature.

physics.ins-det

Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC

The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.

physics.ins-det

Neutrino Physics with an Opaque Detector

In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.

physics.ins-det

A Light Calibration System for the ProtoDUNE-DP Detector

A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber currently being installed at the Neutrino Platform at CERN. The PDS is based on 36 8-inch photomultiplier tubes (PMTs) and will allow triggering on cosmic rays. The system serves as prototype for the PDS of the final DUNE DP far detector in which the PDS also has the function to allow the 3D event reconstruction on non-beam physics. For this purpose an equalized PMT response is desirable to allow using the same threshold definition for all PMT groups, simplifying the determination of the trigger efficiency. The light calibration system described in this paper is developed to provide this and to monitor the PMT performance in-situ.

physics.ins-det

Cryogenic R5912-20Mod Photomultiplier Tube Characterization for the ProtoDUNE Dual Phase Detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long baseline neutrino oscillation studies, and for neutrino astrophysics and nucleon decay searches. The far detector is a 40-kton underground liquid argon time-projection-chamber (LAr TPC), in which the photon detector system adds precise timing capabilities. The ProtoDUNE dual phase detector will consist of a 6x6x6 m^3 LAr TPC to be operated at the CERN Neutrino Platform and the photon detection system will be formed by 8-inch cryogenic photomultipliers from Hamamatsu. The PMT model (R5912-20Mod) performance at cryogenic temperature is studied including dark current, gain, and linearity with the light intensity and pulse rate. In addition, the PMT base design is validated. At cold, a decrease of the PMT amplification, or fatigue effect, is measured as the PMT output current increases, either, due to high gain, light intensity or rate. Also, the characterisation results of the 40 photomultipliers to be used in ProtoDUNE dual phase are presented.

physics.ins-det