SearcharxivSearch

arXiv subjects

E. Capocasa

Publications and source records attributed to E. Capocasa.

At least 19 recordsLinked to original sources

Advanced Virgo Plus for O5 -- Design Report Overview

This document presents an overview of the design, implementation, and expected performance of the Advanced Virgo Plus (AdV+) upgrades in view of the O5 observing run. Following the experience gained during the O4 commissioning and operations, the Virgo Collaboration has revised the upgrade strategy to address limitations associated with marginally stable recycling cavities. The O5 upgrade program combines elements from the original AdV+ Phase II project with new design solutions, including the implementation of stable recycling cavities, a major modification to the central interferometer layout, and a comprehensive renewal of critical subsystems. The planned upgrades are organized in two steps, targeting progressive improvements in operational stability, noise reduction, and detector sensitivity. Key developments include new vacuum infrastructures, suspensions, mirrors, optical configurations, quantum noise reduction systems, and high-power laser technologies. The resulting configuration is expected to significantly enhance the interferometer performance, enabling a substantial increase in astrophysical reach and scientific return during O5.

astro-ph.IM

Optical losses as a function of beam position on the mirrors in a 285-m suspended Fabry-Perot cavity

Reducing optical losses is crucial for reducing quantum noise in gravitational-wave detectors. Losses are the main source of degradation of the squeezed vacuum. Frequency dependent squeezing obtained via a filter cavity is currently used to reduce quantum noise in the whole detector bandwidth. Such filter cavities are required to have high finesse in order to produce the optimal squeezing angle rotation and the presence of losses is particularly detrimental for the squeezed beam, as it does multiple round trip within the cavity. Characterising such losses is crucial to assess the quantum noise reduction achievable. In this paper we present an in-situ measurement of the optical losses, done for different positions of the beam on the mirrors of the Virgo filter cavity. We implemented an automatic system to map the losses with respect to the beam position on the mirrors finding that optical losses depend clearly on the beam hitting position on input mirror, varying from 42 ppm to 87 ppm, while they are much more uniform when we scan the end mirror (53 ppm to 61 ppm). We repeated the measurements on several days, finding a statistical error smaller than 4 ppm. The lowest measured losses are not much different with respect to those estimated from individual mirror characterisation performed before the installation (30.3 - 39.3 ppm). This means that no major loss mechanism has been neglected in the estimation presented here. The larger discrepancy found for some beam positions is likely to be due to contamination. In addition to a thorough characterisation of the losses, the methodology described in this paper allowed to find an optimal cavity axis position for which the cavity round trip losses are among the lowest ever measured. This work can contribute to achieve the very challenging losses goals for the optical cavities of the future gravitational-wave detectors.

physics.ins-det

Virgo Detector Characterization and Data Quality: results from the O3 run

The Advanced Virgo detector has contributed with its data to the rapid growth of the number of detected gravitational-wave (GW) signals in the past few years, alongside the two Advanced LIGO instruments. First during the last month of the Observation Run 2 (O2) in August 2017 (with, most notably, the compact binary mergers GW170814 and GW170817), and then during the full Observation Run 3 (O3): an 11-months data taking period, between April 2019 and March 2020, that led to the addition of about 80 events to the catalog of transient GW sources maintained by LIGO, Virgo and now KAGRA. These discoveries and the manifold exploitation of the detected waveforms require an accurate characterization of the quality of the data, such as continuous study and monitoring of the detector noise sources. These activities, collectively named {\em detector characterization and data quality} or {\em DetChar}, span the whole workflow of the Virgo data, from the instrument front-end hardware to the final analyses. They are described in details in the following article, with a focus on the results achieved by the Virgo DetChar group during the O3 run. Concurrently, a companion article describes the tools that have been used by the Virgo DetChar group to perform this work.

gr-qc

Virgo Detector Characterization and Data Quality: tools

Detector characterization and data quality studies -- collectively referred to as {\em DetChar} activities in this article -- are paramount to the scientific exploitation of the joint dataset collected by the LIGO-Virgo-KAGRA global network of ground-based gravitational-wave (GW) detectors. They take place during each phase of the operation of the instruments (upgrade, tuning and optimization, data taking), are required at all steps of the dataflow (from data acquisition to the final list of GW events) and operate at various latencies (from near real-time to vet the public alerts to offline analyses). This work requires a wide set of tools which have been developed over the years to fulfill the requirements of the various DetChar studies: data access and bookkeeping; global monitoring of the instruments and of the different steps of the data processing; studies of the global properties of the noise at the detector outputs; identification and follow-up of noise peculiar features (whether they be transient or continuously present in the data); quick processing of the public alerts. The present article reviews all the tools used by the Virgo DetChar group during the third LIGO-Virgo Observation Run (O3, from April 2019 to March 2020), mainly to analyse the Virgo data acquired at EGO. Concurrently, a companion article focuses on the results achieved by the DetChar group during the O3 run using these tools.

gr-qc

Input optics systems of the KAGRA detector during O3GK

KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.

gr-qc

Noise subtraction from KAGRA O3GK data using Independent Component Analysis

In April 2020, KAGRA conducted its first science observation in combination with the GEO~600 detector (O3GK) for two weeks. According to the noise budget estimation, suspension control noise in the low frequency band and acoustic noise in the middle frequency band are identified as the dominant contribution. In this study, we show that such noise can be reduced in offline data analysis by utilizing a method called Independent Component Analysis (ICA). Here the ICA model is extended from the one studied in iKAGRA data analysis by incorporating frequency dependence while linearity and stationarity of the couplings are still assumed. By using optimal witness sensors, those two dominant contributions are mitigated in the real observational data. We also analyze the stability of the transfer functions for whole two weeks data in order to investigate how the current subtraction method can be practically used in gravitational wave search.

astro-ph.IM

Virgo Detector Characterization and Data Quality during the O3 run

The Advanced Virgo detector has contributed with its data to the rapid growth of the number of detected gravitational-wave signals in the past few years, alongside the two LIGO instruments. First, during the last month of the Observation Run 2 (O2) in August 2017 (with, most notably, the compact binary mergers GW170814 and GW170817) and then during the full Observation Run 3 (O3): an 11 months data taking period, between April 2019 and March 2020, that led to the addition of about 80 events to the catalog of transient gravitational-wave sources maintained by LIGO, Virgo and KAGRA. These discoveries and the manifold exploitation of the detected waveforms require an accurate characterization of the quality of the data, such as continuous study and monitoring of the detector noise. These activities, collectively named {\em detector characterization} or {\em DetChar}, span the whole workflow of the Virgo data, from the instrument front-end to the final analysis. They are described in details in the following article, with a focus on the associated tools, the results achieved by the Virgo DetChar group during the O3 run and the main prospects for future data-taking periods with an improved detector.

gr-qc

Performance of the KAGRA detector during the first joint observation with GEO 600 (O3GK)

KAGRA, the kilometer-scale underground gravitational-wave detector, is located at Kamioka, Japan. In April 2020, an astrophysics observation was performed at the KAGRA detector in combination with the GEO 600 detector; this observation operation is called O3GK. The optical configuration in O3GK is based on a power recycled Fabry-P\'{e}rot Michelson interferometer; all the mirrors were set at room temperature. The duty factor of the operation was approximately 53%, and the strain sensitivity was $3\times10^{-22}~/\sqrt{\rm{Hz}}$ at 250 Hz. In addition, the binary-neutron-star (BNS) inspiral range was approximately 0.6 Mpc. The contributions of various noise sources to the sensitivity of O3GK were investigated to understand how the observation range could be improved; this study is called a "noise budget". According to our noise budget, the measured sensitivity could be approximated by adding up the effect of each noise. The sensitivity was dominated by noise from the sensors used for local controls of the vibration isolation systems, acoustic noise, shot noise, and laser frequency noise. Further, other noise sources that did not limit the sensitivity were investigated. This paper provides a detailed account of the KAGRA detector in O3GK including interferometer configuration, status, and noise budget. In addition, strategies for future sensitivity improvements such as hardware upgrades, are discussed.

astro-ph.IM

The Virgo O3 run and the impact of the environment

Sources of geophysical noise (such as wind, sea waves and earthquakes) or of anthropogenic noise impact ground-based gravitational-wave interferometric detectors, causing transient sensitivity worsening and gaps in data taking. During the one year-long third Observing Run (O3: from April 01, 2019 to March 27, 2020), the Virgo Collaboration collected a statistically significant dataset, used in this article to study the response of the detector to a variety of environmental conditions. We correlated environmental parameters to global detector performance, such as observation range, duty cycle and control losses. Where possible, we identified weaknesses in the detector that will be used to elaborate strategies in order to improve Virgo robustness against external disturbances for the next data taking period, O4, currently planned to start at the end of 2022. The lessons learned could also provide useful insights for the design of the next generation of ground-based interferometers.

gr-qc

Overview of KAGRA: Calibration, detector characterization, physical environmental monitors, and the geophysics interferometer

KAGRA is a newly built gravitational wave observatory, a laser interferometer with a 3 km arm length, located in Kamioka, Gifu, Japan. In this series of articles, we present an overview of the baseline KAGRA, for which we finished installing the designed configuration in 2019. This article describes the method of calibration (CAL) used for reconstructing gravitational wave signals from the detector outputs, as well as the characterization of the detector (DET). We also review the physical environmental monitors (PEM) system and the geophysics interferometer (GIF). Both are used for characterizing and evaluating the data quality of the gravitational wave channel. They play important roles in utilizing the detector output for gravitational wave searches. These characterization investigations will be even more important in the near future, once gravitational wave detection has been achieved, and in using KAGRA in the gravitational wave astronomy era.

gr-qc

Overview of KAGRA : KAGRA science

KAGRA is a newly build gravitational-wave observatory, a laser interferometer with 3 km arm length, located in Kamioka, Gifu, Japan. In this paper in the series of KAGRA-featured articles, we discuss the science targets of KAGRA projects, considering not only the baseline KAGRA (current design) but also its future upgrade candidates (KAGRA+) for the near to middle term (~5 years).

gr-qc

Overview of KAGRA: Detector design and construction history

KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.

physics.ins-det

Application of the independent component analysis to the iKAGRA data

We apply the independent component analysis (ICA) to the real data from a gravitational wave detector for the first time. Specifically we use the iKAGRA data taken in April 2016, and calculate the correlations between the gravitational wave strain channel and 35 physical environmental channels. Using a couple of seismic channels which are found to be strongly correlated with the strain, we perform ICA. Injecting a sinusoidal continuous signal in the strain channel, we find that ICA recovers correct parameters with enhanced signal-to-noise ratio, which demonstrates usefulness of this method. Among the two implementations of ICA used here, we find the correlation method yields the optimal result for the case environmental noises act on the strain channel linearly.

astro-ph.IM

An arm length stabilization system for KAGRA and future gravitational-wave detectors

Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.

physics.ins-det

First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA

KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.

astro-ph.IM

Vibration isolation system with a compact damping system for power recycling mirrors of KAGRA

A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient damping performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the damping performance, and also on estimated residual displacement of the optics.

physics.ins-det

A standard siren measurement of the Hubble constant from GW170817 without the electromagnetic counterpart

We perform a statistical standard siren analysis of GW170817. Our analysis does not utilize knowledge of NGC 4993 as the unique host galaxy of the optical counterpart to GW170817. Instead, we consider each galaxy within the GW170817 localization region as a potential host; combining the redshift from each galaxy with the distance estimate from GW170817 provides an estimate of the Hubble constant, $H_0$. We then combine the $H_0$ values from all the galaxies to provide a final measurement of $H_0$. We explore the dependence of our results on the thresholds by which galaxies are included in our sample, as well as the impact of weighting the galaxies by stellar mass and star-formation rate. Considering all galaxies brighter than $0.01 L^\star_B$ as equally likely to host a BNS merger, we find $H_0= 76^{+48}_{-23}$ km s$^{-1}$ Mpc$^{-1}$ (maximum a posteriori and 68.3% highest density posterior interval; assuming a flat $H_0$ prior in the range $\left[ 10, 220 \right]$ km s$^{-1}$ Mpc$^{-1}$). Restricting only to galaxies brighter than $0.626 L^\star_B$ tightens the measurement to $H_0= 77^{+37}_{-18}$ km s$^{-1}$ Mpc$^{-1}$. We show that weighting the host galaxies by stellar mass or star-formation rate provides entirely consistent results with potentially tighter constraints. While these statistical estimates are inferior to the value from the counterpart standard siren measurement utilizing NGC 4993 as the unique host, $H_0=76^{+19}_{-13}$ km s$^{-1}$ Mpc$^{-1}$ (determined from the same publicly available data), our analysis is a proof-of-principle demonstration of the statistical approach first proposed by Bernard Schutz over 30 years ago.

astro-ph.CO

KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector

The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.

gr-qc