SearcharxivSearch

arXiv subjects

E. Castelli

Publications and source records attributed to E. Castelli.

8 recordsLinked to original sources

In-depth analysis of LISA Pathfinder performance results: Time evolution, noise projection, physical models, and implications for LISA

We present an in-depth analysis of the LISA Pathfinder differential acceleration performance over the entire course of its science operations, spanning approximately 500 days. We find that: 1) the evolution of the Brownian noise that dominates the acceleration amplitude spectral density (ASD), for frequencies $f\gtrsim 1\,\text{mHz}$, is consistent with the decaying pressure due to the outgassing of a single gaseous species. 2) between $f=36\,\mu\text{Hz}$ and $1\,\text{mHz}$, the acceleration ASD shows a $1/f$ tail in excess of the Brownian noise of almost constant amplitude, with $\simeq 20\%$ fluctuations over a period of a few days, with no particular time pattern over the course of the mission; 3) at the lowest considered frequency of $f=18\,\mu\text{Hz}$, the ASD significantly deviates from the $1/f$ behavior, because of temperature fluctuations that appear to modulate a quasi-static pressure gradient, sustained by the asymmetries of the outgassing pattern. We also present the results of a projection of the observed acceleration noise on the potential sources for which we had either a direct correlation measurement, or a quantitative estimate from dedicated experiments. These sources account for approximately $40\%$ of the noise power in the $1/f$ tail. Finally, we analyze the possible sources of the remaining unexplained fraction, and identify the possible measures that may be taken to keep those under control in LISA.

astro-ph.IM

Charging of free-falling test masses in orbit due to cosmic rays: results from LISA Pathfinder

A comprehensive summary of the measurements made to characterize test mass charging due to the space environment during the LISA Pathfinder mission is presented. Measurements of the residual charge of the test mass after release by the grabbing and positioning mechanism, show that the initial charge of the test masses was negative after all releases, leaving the test mass with a potential in the range $-12$ mV to $-512$ mV. Variations in the neutral test mass charging rate between $21.7$ e s$^{-1}$ and $30.7$ e s$^{-1}$ were observed over the course of the 17-month science operations produced by cosmic ray flux changes including a Forbush decrease associated with a small solar energetic particle event. A dependence of the cosmic ray charging rate on the test mass potential between $-30.2$ e s$^{-1}$ V$^{-1}$ and $-40.3$ e s$^{-1}$ V$^{-1}$ was observed and this is attributed to a contribution to charging from low-energy electrons emitted from the gold surfaces of the gravitational reference sensor. Data from the on-board particle detector show a reliable correlation with the charging rate and with other environmental monitors of the cosmic ray flux. This correlation is exploited to extrapolate test mass charging rates to a 20-year period giving useful insight into the expected range of charging rate that may be observed in the LISA mission.

astro-ph.IM

Spacecraft and interplanetary contributions to the magnetic environment on-board LISA Pathfinder

LISA Pathfinder (LPF) has been a space-based mission designed to test new technologies that will be required for a gravitational wave observatory in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime (mHz and below), the measurement band of interest for a space-based observatory. The magnetic field can couple to the magnetic susceptibility and remanent magnetic moment from the test masses and disturb them from their geodesic movement. LISA Pathfinder carried on-board a dedicated magnetic measurement subsystem with noise levels of 10 $ \rm nT \ Hz^{-1/2}$ from 1 Hz down to 1 mHz. In this paper we report on the magnetic measurements throughout LISA Pathfinder operations. We characterise the magnetic environment within the spacecraft, study the time evolution of the magnetic field and its stability down to 20 $\mu$Hz, where we measure values around 200 $ \rm nT \ Hz^{-1/2}$ and identify two different frequency regimes, one related to the interplanetary magnetic field and the other to the magnetic field originating inside the spacecraft. Finally, we characterise the non-stationary component of the fluctuations of the magnetic field below the mHz and relate them to the dynamics of the solar wind.

astro-ph.IM

LISA Pathfinder Performance Confirmed in an Open-Loop Configuration: Results from the Free-Fall Actuation Mode

We report on the results of the LISA Pathfinder (LPF) free-fall mode experiment, in which the control force needed to compensate the quasistatic differential force acting on two test masses is applied intermittently as a series of "impulse" forces lasting a few seconds and separated by roughly 350 s periods of true free fall. This represents an alternative to the normal LPF mode of operation in which this balancing force is applied continuously, with the advantage that the acceleration noise during free fall is measured in the absence of the actuation force, thus eliminating associated noise and force calibration errors. The differential acceleration noise measurement presented here with the free-fall mode agrees with noise measured with the continuous actuation scheme, representing an important and independent confirmation of the LPF result. An additional measurement with larger actuation forces also shows that the technique can be used to eliminate actuation noise when this is a dominant factor.

physics.space-ph

Temperature stability in the sub-milliHertz band with LISA Pathfinder

LISA Pathfinder (LPF) was a technology pioneering mission designed to test key technologies required for gravitational wave detection in space. In the low frequency regime (milli-Hertz and below), where space-based gravitational wave observatories will operate, temperature fluctuations play a crucial role since they can couple into the interferometric measurement and the test masses' free-fall accuracy in many ways. A dedicated temperature measurement subsystem, with noise levels in 10$\,\mu$K$\,$Hz$^{-1/2}$ down to $1\,$mHz was part of the diagnostics unit on board LPF. In this paper we report on the temperature measurements throughout mission operations, characterize the thermal environment, estimate transfer functions between different locations and report temperature stability (and its time evolution) at frequencies as low as 10$\,\mu$Hz, where typically values around $1\,$K$\,$Hz$^{-1/2}$ were measured.

astro-ph.IM

Forbush decreases and $<$ 2-day GCR flux non-recurrent variations studied with LISA Pathfinder

Non-recurrent short term variations of the galactic cosmic-ray (GCR) flux above 70 MeV n$^{-1}$ were observed between 2016 February 18 and 2017 July 3 aboard the European Space Agency LISA Pathfinder (LPF) mission orbiting around the Lagrange point L1 at 1.5$\times$10$^6$ km from Earth. The energy dependence of three Forbush decreases (FDs) is studied and reported here. A comparison of these observations with others carried out in space down to the energy of a few tens of MeV n$^{-1}$ shows that the same GCR flux parameterization applies to events of different intensity during the main phase. FD observations in L1 with LPF and geomagnetic storm occurrence is also presented. Finally, the characteristics of GCR flux non-recurrent variations (peaks and depressions) of duration $<$ 2 days and their association with interplanetary structures are investigated. It is found that, most likely, plasma compression regions between subsequent corotating high-speed streams cause peaks, while heliospheric current sheet crossing cause the majority of the depressions.

physics.space-ph

Precision Charge Control for Isolated Free-Falling Test Masses: LISA Pathfinder Results

The LISA Pathfinder charge management device was responsible for neutralising the cosmic ray induced electric charge that inevitably accumulated on the free-falling test masses at the heart of the experiment. We present measurements made on ground and in-flight that quantify the performance of this contactless discharge system which was based on photo-emission under UV illumination. In addition, a two-part simulation is described that was developed alongside the hardware. Modelling of the absorbed UV light within the Pathfinder sensor was carried out with the GEANT4 software toolkit and a separate MATLAB charge transfer model calculated the net photocurrent between the test masses and surrounding housing in the presence of AC and DC electric fields. We confront the results of these models with observations and draw conclusions for the design of discharge systems for future experiments like LISA that will also employ free-falling test masses.

physics.ins-det

Calibrating the system dynamics of LISA Pathfinder

LISA Pathfinder (LPF) was a European Space Agency mission with the aim to test key technologies for future space-borne gravitational-wave observatories like LISA. The main scientific goal of LPF was to demonstrate measurements of differential acceleration between free-falling test masses at the sub-femto-g level, and to understand the residual acceleration in terms of a physical model of stray forces, and displacement readout noise. A key step toward reaching the LPF goals was the correct calibration of the dynamics of LPF, which was a three-body system composed by two test-masses enclosed in a single spacecraft, and subject to control laws for system stability. In this work, we report on the calibration procedures adopted to calculate the residual differential stray force per unit mass acting on the two test-masses in their nominal positions. The physical parameters of the adopted dynamical model are presented, together with their role on LPF performance. The analysis and results of these experiments show that the dynamics of the system was accurately modeled and the dynamical parameters were stationary throughout the mission. Finally, the impact and importance of calibrating system dynamics for future space-based gravitational wave observatories is discussed.

astro-ph.IM