SearcharxivSearch

arXiv subjects

E. Chauveau

Publications and source records attributed to E. Chauveau.

At least 19 recordsLinked to original sources

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8$\times$8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 $μ$m per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

physics.ins-det

First Measurement of Neutrino Emissions from Spent Nuclear Fuel by the Double Chooz Experiment

Neutrino emission from nuclear reactors provides real-time insights into reactor power and fuel evolution, with potential applications in monitoring and nuclear safeguards. Following reactor shutdown, a low-intensity flux of ``residual neutrinos'' persists due to the decay of long-lived fission isotopes in the partially burnt fuel remaining within the reactor cores and in spent nuclear fuel stored in nearby cooling pools. The Double Chooz experiment at the Chooz B nuclear power plant in France achieved the first quantitative measurement of this residual flux based on 17.2 days of reactor-off data. In the energy range where the residual signal is most pronounced, the neutrino detector located 400$\,$m from the cores recorded $106 \pm 18$ neutrino candidate events (5.9$σ$ significance). This measurement is in excellent agreement with the predicted value of $88 \pm 7$ events derived from detailed reactor simulations modeling the decay activities of fission products and incorporating the best-available models of neutrino spectra.

hep-ex

Fabrication of thin planar radiopure foils with 82Se for the SuperNEMO Demonstrator

The SuperNEMO Demonstrator, designed to search for double beta decay using enriched 82Se, has been assembled in the Modane Underground Laboratory under the French Alps. Thin foils with radio - purified and enriched 82Se are installed centrally in the detector. A novel foil fabrication method has been developed, improving the radiopurity achieved in the previous generation experiment. It consists of wrapping standalone selenium pads in raw Mylar, combined with selenium purified by a new reverse-chromatography method. This paper describes the features of these foils, their fabrication process, the characterization results, and the integration of the foils into the SuperNEMO Demonstrator.

physics.ins-det

COCOA: a compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

astro-ph.IM

Calorimeter commissioning of the SuperNEMO Demonstrator

The SuperNEMO experiment is searching for neutrinoless double beta decay of \textsuperscript{82}Se, with the unique combination of a tracking detector and a segmented calorimeter. This feature allows to detect the two electrons emitted in the decay and measure their individual energy and angular distribution. The SuperNEMO calorimeter consists of 712 plastic scintillator blocks readout by large PMTs. After the construction of the demonstrator calorimeter underground, we have performed its first commissioning using $γ$-particles from calibration sources or from the ambient radioactive background. This article presents the quality assurance tests of the SuperNEMO demonstrator calorimeter and its first time and energy calibrations, with the associated methods.

physics.ins-det

The Stochastic Light Confinement of LiquidO

Light-based detectors have been widely used in fundamental research and industry since their inception in the 1930s. The energy particles deposit in these detectors is converted to optical signals via the Cherenkov and scintillation mechanisms that are then propagated through transparent media to photosensors placed typically on the detector's periphery, sometimes up to tens of metres away. LiquidO is a new technique pioneering the use of opaque media to stochastically confine light around each energy deposition while collecting it with an array of fibres that thread the medium. This approach preserves topological event information otherwise lost in the conventional approach, enabling real-time imaging down to the MeV scale. Our article demonstrates LiquidO's imaging principle with a ten-litre prototype, revealing successful light confinement of 90% of the detected light within a 5 cm radius sphere, using a custom opaque scintillator with a scattering length on the order of a few millimetres. These high-resolution imaging capabilities unlock opportunities in fundamental physics research and applications beyond. The absolute amount of light detected is also studied, including possible data-driven extrapolations to LiquidO-based detectors beyond prototyping limitations. Additionally, LiquidO's timing capabilities are explored through its ability to distinguish Cherenkov light from a slow scintillator.

physics.ins-det

The Impact of Helium Exposure on the PMTs of the SuperNEMO Experiment

The performance of Hamamatsu 8" photomultiplier tubes (PMTs) of the type used in the SuperNEMO neutrinoless double-beta decay experiment (R5912-MOD), is investigated as a function of exposure to helium (He) gas. Two PMTs were monitored for over a year, one exposed to varying concentrations of He, and the other kept in standard atmospheric conditions as a control. Both PMTs were exposed to light signals generated by a Bi-207 radioactive source that provided consistent large input PMT signals similar to those that are typical of the SuperNEMO experiment. The energy resolution of PMT signals corresponding to 1 MeV energy scale determined from the Bi-207 decay spectrum, shows a negligible degradation with He exposure; however the rate of after-pulsing shows a clear increase with He exposure, which is modelled and compared to diffusion theory. A method for reconstructing the partial pressure of He within the PMT and a method for determining the He breakdown point, are introduced. The implications for long-term SuperNEMO operations are briefly discussed.

physics.ins-det

Development of a real-time tritium-in-water monitor

In this paper, we report the development and performance of a detector module envisaging a tritium-in-water real-time activity monitor. The monitor is based on modular detection units whose number can be chosen according to the required sensitivity. The full system is being designed to achieve a \emph{Minimum Detectable Activity} (\emph{MDA}) of 100\,Bq/L of tritium-in-water activity which is the limit established by the E.U. Council Directive 2013/51/Euratom for water intended for human consumption. The same system can be used as a real-time pre-alert system for nuclear power plant regarding tritium-in water environmental surveillance. The first detector module was characterized, commissioned and installed immediately after the discharge channel of the Arrocampo dam (Almaraz nuclear power plant, Spain) on the Tagus river. Due to the high sensitivity of the single detection modules, the system requires radioactive background mitigation techniques through the use of active and passive shielding. We have extrapolated a \emph{MDA} of 3.6\,kBq/L for a single module being this value limited by the cosmic background. The obtained value for a single module is already compatible with a real-time environmental surveillance and pre-alert system. Further optimization of the single-module sensitivity will imply the reduction of the number of modules and the cost of the detector system.

physics.ins-det

Measurement of double-$β$ decay of $^{150}$Nd to the 0$^+_1$ excited state of $^{150}$Sm in NEMO-3

The NEMO-3 results for the double-$β$ decay of $^{150}$Nd to the 0$^+_1$ and 2$^+_1$ excited states of $^{150}$Sm are reported. The data recorded during 5.25 yr with 36.6 g of the isotope $^{150}$Nd are used in the analysis. For the first time, the signal of the $2νββ$ transition to the 0$^+_1$ excited state is detected with a statistical significance exceeding 5$σ$. The half-life is measured to be $T_{1/2}^{2νββ}(0^+_1) = \left[ 1.11 ^{+0.19}_{-0.14} \,\left(\mbox{stat}\right) ^{+0.17}_{-0.15}\, \left(\mbox{syst}\right) \right] \times10^{20}\,\mbox{yr}$. The limits are set on the $2νββ$ decay to the 2$^+_1$ level and on the $0νββ$ decay to the 0$^+_1$ and 2$^+_1$ levels of $^{150}$Sm.

nucl-ex

Probing Earth's Missing Potassium using the Unique Antimatter Signature of Geoneutrinos

The formation of the Earth remains an epoch with mysterious puzzles extending to our still incomplete understanding of the planet's potential origin and bulk composition. Direct confirmation of the Earth's internal heat engine was accomplished by the successful observation of geoneutrinos originating from uranium (U) and thorium (Th) progenies, manifestations of the planet's natural radioactivity dominated by potassium (40K) and the decay chains of uranium (238U) and thorium (232Th). This radiogenic energy output is critical to planetary dynamics and must be accurately measured for a complete understanding of the overall heat budget and thermal history of the Earth. Detecting geoneutrinos remains the only direct probe to do so and constitutes a challenging objective in modern neutrino physics. In particular, the intriguing potassium geoneutrinos have never been observed and thus far have been considered impractical to measure. We propose here a novel approach for potassium geoneutrino detection using the unique antimatter signature of antineutrinos to reduce the otherwise overwhelming backgrounds to observing this rarest signal. The proposed detection framework relies on the innovative LiquidO detection technique to enable positron (e+) identification and antineutrino interactions with ideal isotope targets identified here for the first time. We also provide the complete experimental methodology to yield the first potassium geoneutrino discovery.

physics.geo-ph

Gate tunable terahertz cyclotron emission from two-dimensional Dirac fermions

Two-dimensional Dirac fermions in HgTe quantum wells close to the topological phase transition can generate significant cyclotron emission that is magnetic field tunable in the Terahertz (THz) frequency range. Due to their relativistic-like dynamics, their cyclotron mass is strongly dependent on their electron concentration in the quantum well, providing a second tunability lever and paving the way for a gate-tunable, permanent-magnet Landau laser. In this work, we demonstrate the proof-of-concept of such a back-gate tunable THz cyclotron emitter at fixed magnetic field. The emission frequency detected at 1.5 Tesla is centered on 2.2 THz and can already be electrically tuned over 250 GHz. With an optimized gate and a realistic permanent magnet of 1.0 Tesla, we estimate that the cyclotron emission could be continuously and rapidly tunable by the gate bias between 1 and 3 THz, that is to say on the less covered part of the THz gap.

cond-mat.mes-hall

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det

Neutrino Physics with an Opaque Detector

In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.

physics.ins-det

Search for Signatures of Sterile Neutrinos with Double Chooz

We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e.\ comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range $5 \cdot 10^{-3} $ eV$^2 \lesssim Δm^2_{41} \lesssim 3\cdot 10^{-1} $ eV$^2$ for mixing angles down to $\sin^2 2θ_{14} \gtrsim 0.02$. No significant disappearance additionally to the conventional disappearance related to $θ_{13} $ is observed and correspondingly exclusion bounds on the sterile mixing parameter $θ_{14} $ as function of $ Δm^2_{41} $ are obtained.

hep-ex

Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO

The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly. The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.

physics.ins-det

Reactor Rate Modulation oscillation analysis with two detectors in Double Chooz

A $θ_{13}$ oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of $θ_{13}$ and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the \nue interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and $^{9}$Li decays. The background-model-independent determination of the mixing angle yields sin$^2(2θ_{13})=0.094\pm0.017$, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on $θ_{13}$ to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86\%, reducing the 1.43\% uncertainty associated to the expectation.

hep-ex

Search for Periodic Modulations of the Rate of Double-Beta Decay of $^{100}$Mo in the NEMO-3 Detector

Double-beta decays of $^{100}$Mo from the 6.0195-year exposure of a 6.914 kg high-purity sample were recorded by the NEMO-3 experiment that searched for neutrinoless double-beta decays. These ultra-rare transitions to $^{100}$Ru have a half-life of approximately $7\times10^{18}$ years, and have been used to conduct the first ever search for periodic variations of this decay mode. The Lomb-Scargle periodogram technique, and its error-weighted extension, were employed to look for periodic modulations of the half-life. Monte Carlo modeling was used to study the modulation sensitivity of the data over a broad range of amplitudes and frequencies. Data show no evidence of modulations with amplitude greater than 2.5% in the frequency range of $0.33225\,{\rm y^{-1}}$ to $365.25\,{\rm y^{-1}}$.

nucl-ex

Simulation results on a real-time in water tritium monitor

In this work we present simulation results for a modular tritium in-water real-time monitor. The system allows for scalability in order to achieve the required sensitivity. The modules are composed by 340 uncladed scintillating fibers immersed in water and 2 photosensors for light readout. Light yield and Birks' coefficient uncertainties for low energy beta particles is discussed. A study of the detection efficiency according to the fiber length is presented. Discussion on the system requirements and background mitigation for a device with sensitivity of 100\,Bq/L, required to comply with the European directive 2013/51/Euratom, is presented. Due to the low energetic beta emission from tritium a detection efficiency close to 3.3\% was calculated for a single 2\,mm round fiber.

physics.ins-det