SearcharxivSearch

arXiv subjects

E. Chen

Publications and source records attributed to E. Chen.

5 recordsLinked to original sources

Measurements of the Beam Longitudinal Properties in the Fermilab Linac

The Fermilab Linac delivers 400MeV, 25mA H$^-$; beam. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the phase of an upstream cavity and fitted to simulations. The cavity gradient and its phase with respect to the beam are recovered from readings of Beam Position Monitors (BPMs). Since the cavity provides a significant transverse defocusing, the BSM measurements are correlated with transverse beam size measurements by a wire scanner (WS). Simulations connect these three types of measurements, allowing to deduce the longitudinal emittance and Courant-Snyder parameters.

physics.acc-ph

Optics Reconstruction in the SCL Section of the FNAL Linac

The Side-Coupled Linac (SCL) section of the FNAL linac accelerates the beam from 117 MeV to 401.5 MeV, operating at 22-24 mA beam current. Transverse focusing is performed by 32 quadrupoles, and the beam orbit is guided by 19 dipole correctors and measured by 29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings of an upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code TraceWin. A comparison between TraceWin simulations and the beam envelope measured by the 12 wire scanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance of the transition section will be reported.

physics.acc-ph

Emittance Measurements with Wire Scanners in the Fermilab Side-coupled Linac

The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam's transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions, which we present here.

physics.acc-ph

Study and mitigation of spurious electron emission from cathodic wires in noble liquid time projection chambers

Noble liquid radiation detectors have long been afflicted by spurious electron emission from their cathodic electrodes. This phenomenon must be understood and mitigated in the next generation of liquid xenon (LXe) experiments searching for WIMP dark matter or neutrinoless double beta decay, and in the large liquid argon (LAr) detectors for the long-baseline neutrino programmes. We present a systematic study of this spurious emission involving a series of slow voltage-ramping tests on fine metal wires immersed in a two-phase xenon time projection chamber with single electron sensitivity. Emission currents as low as $10^{-18}$ A can thus be detected by electron counting, a vast improvement over previous dedicated measurements. Emission episodes were recorded at surface fields as low as $\sim$10 kV/cm in some wires and observed to have complex emission patterns, with average rates of 10-200 counts per second (c/s) and outbreaks as high as $\sim$10$^6$ c/s. A fainter, less variable type of emission was also present in all untreated samples. There is evidence of a partial conditioning effect, with subsequent tests yielding on average fewer emitters occurring at different fields for the same wire. We find no evidence for an intrinsic threshold particular to the metal-LXe interface which might have limited previous experiments up to fields of at least 160 kV/cm. The general phenomenology is not consistent with enhanced field emission from microscopic filaments, but it appears instead to be related to the quality of the wire surface in terms of corrosion and the nature of its oxide layer. This study concludes that some surface treatments, in particular nitric acid cleaning for stainless steel wires, can bringing about at least order-of-magnitude improvements in overall electron emission rates, and this should help the next generation of detectors achieve the required electrostatic performance.

physics.ins-det

Tests of a High Resolution Time of Flight System Based on Long and Narrow Scintillator

We have tested a prototype time-of-flight system based on bulk scintillator block of dimensions $2.5 \times 2.5 \times 200$ cm. Using a calibration scheme similar to the one used in actual collider experiments, we have achieved a resolution of 71 ps using Amperex XP2020/UR photomultipliers and 81 ps using proximity-focusing fine-mesh photomultipliers (Hamamatsu R2021). Results are also obtained for scintillating fiber blocks of the same dimensions. Good internal reflectivity of the bulk scintillator block resulted in resolutions superior to the fibre blocks. A single-photon pulsed laser system was used to study photomultipliers and the results were used in a Monte Carlo simulation of the system to study the critical elements that determine the resolution.

hep-ex