SearcharxivSearch

arXiv subjects

E. Dane'

Publications and source records attributed to E. Dane'.

6 recordsLinked to original sources

Dark Matter Sensitivity of the CYGNO Detector with HFO-1234ze Enhanced Gas Mixtures

The CYGNO collaboration introduces an innovative approach to direct dark matter detection, proposing a high-resolution optical Time Projection Chamber. It operates at atmospheric pressure with a He:CF$_{4}$ (60:40) gas mixture and uses a triple Gas Electron Multiplier stage for signal amplification. A key feature is its optical readout system, which captures the scintillation light produced during the electron avalanche. This setup allows 3D event reconstruction by combining the time profile of the light detected by photomultiplier tubes with high-granularity, pixelated X-Y tracking recorded by a scientific camera. The CYGNO experiment's projected sensitivity to both spin-independent and spin-dependent interactions is competitive in the framework of directional dark matter detectors. However, incorporating a hydrogen-based gas would introduce an even lighter target, further improving the detection potential at low dark matter masses. In this work, we present the performance characterization of one of the CYGNO experiment prototypes, MANGO, operated with the standard gas mixture enriched with varying concentrations of HFO-1234ze, a gas with a promising low global warming potential. The study includes measurements of the detector charge gain and scintillation yield for each configuration. In addition, to evaluate the impact of HFO-1234ze on scintillation light quenching, the secondary scintillation spectrum was collected for each gas mixture tested.

physics.ins-det

Design and status of the Mu2e electromagnetic calorimeter

The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

physics.ins-det

Search for dark Higgsstrahlung in e+ e- -> mu+ mu- and missing energy events with the KLOE experiment

We searched for evidence of a Higgsstrahlung process in a secluded sector, leading to a final state with a dark photon U and a dark Higgs boson h', with the KLOE detector at DAFNE. We investigated the case of h' lighter than U, with U decaying into a muon pair and h' producing a missing energy signature. We found no evidence of the process and set upper limits to its parameters in the range 2m_mu<m_U<1000 MeV, m_h'<m_U.

hep-ex

Study of Dalitz decay phi -> eta e+e- with KLOE detector

We have studied the vector to pseudoscalar conversion decay phi -> eta e+e-, with eta -> pi0pi0pi0, with the KLOE detector at DAPHNE. The data set of 1.7 fb-1 of e+e- collisions at sqrt(s)~Mphi contains a clear conversion decay signal of ~31,000 events from which we measured a value of BR(phi -> eta e+e-)=(1.075+-0.007+-0.038)x10-4. The same sample is used to determine the transition form factor by a fit to the e+e- invariant mass spectrum, obtaining b(phi eta) =(1.17 +- 0.10 + 0.07) GeV-2, that improves by a factor of five the precision of the previous measurement and is in good agreement with VMD expectations.

hep-ex

Precision measurement of $σ(e^+e^-\rightarrowπ^+π^-γ)/σ(e^+e^-\rightarrow μ^+μ^-γ)$ and determination of the $π^+π^-$ contribution to the muon anomaly with the KLOE detector

We have measured the ratio $σ(e^+e^-\rightarrowπ^+π^-γ)/σ(e^+e^-\rightarrow μ^+μ^-γ)$, with the KLOE detector at DA$Φ$NE for a total integrated luminosity of $\sim$ 240 pb$^{-1}$. From this ratio we obtain the cross section $σ(e^+e^-\rightarrowπ^+π^-)$. From the cross section we determine the pion form factor $|F_π|^2$ and the two-pion contribution to the muon anomaly $a_μ$ for $0.592<M_{ππ}<0.975$ GeV, $Δ^{ππ} a_μ$= $({\rm 385.1\pm1.1_{stat}\pm2.7_{sys+theo}})\times10^{-10}$. This result confirms the current discrepancy between the Standard Model calculation and the experimental measurement of the muon anomaly.

hep-ex

U boson searches at KLOE

The existence of a secluded gauge sector could explain several puzzling astrophysical observations. This hypothesis can be tested at low energy e+e- colliders such as DAPHNE. Preliminary results obtained with KLOE data and perpectives for the KLOE-2 run, where a larger data sample is expected, are discussed.

hep-ex