Searcharxiv⌕ Search

arXiv subjects

E. Daw

Publications and source records attributed to E. Daw.

34 records · Page 2Linked to original sources

Prospects for joint radio telescope and gravitational wave searches for astrophysical transients

The radio skies remain mostly unobserved when it comes to transient phenomena. The direct detection of gravitational waves will mark a major milestone of modern astronomy, as an entirely new window will open on the universe. Two apparently independent phenomena can be brought together in a coincident effort that has the potential to boost both searches. In this paper we will outline the scientific case that stands behind these future joint observations and will describe the methods that might be used to conduct the searches and analyze the data. The targeted sources are binary systems of compact objects, known to be strong candidate sources for gravitational waves. Detection of transients coincident in these two channels would be a significant smoking gun for first direct detection of gravitational waves, and would open up a new field for characterization of astrophysical transients involving massive compact objects.

gr-qc↗

The case for a directional dark matter detector and the status of current experimental efforts

We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

astro-ph.CO↗

Low Energy Electron and Nuclear Recoil Thresholds in the DRIFT-II Negative Ion TPC for Dark Matter Searches

Understanding the ability to measure and discriminate particle events at the lowest possible energy is an essential requirement in developing new experiments to search for weakly interacting massive particle (WIMP) dark matter. In this paper we detail an assessment of the potential sensitivity below 10 keV in the 1 m^3 DRIFT-II directionally sensitive, low pressure, negative ion time projection chamber (NITPC), based on event-by-event track reconstruction and calorimetry in the multiwire proportional chamber (MWPC) readout. By application of a digital smoothing polynomial it is shown that the detector is sensitive to sulfur and carbon recoils down to 2.9 and 1.9 keV respectively, and 1.2 keV for electron induced events. The energy sensitivity is demonstrated through the 5.9 keV gamma spectrum of 55Fe, where the energy resolution is sufficient to identify the escape peak. The effect a lower energy sensitivity on the WIMP exclusion limit is demonstrated. In addition to recoil direction reconstruction for WIMP searches this sensitivity suggests new prospects for applications also in KK axion searches.

hep-ex↗

Proceedings of the 1st International Workshop "Radiopure Scintillators for EURECA" (RPScint'2008)

Workshop RPSCINT'2008 was organized in Kyiv (Ukraine) on 9th and 10th September 2008. The idea was to bring together physicists, chemists, crystal scintillator experts and manufacturers to discuss the requirements of low-count rate experiments, in particular the required radiopurity and scintillation properties; selection and screening of input materials; purification of materials; raw compound preparation; crystal growing, annealing and handling; test of crystals; search for and development of new scintillating materials. Some contributions to the RPSCINT 2008 workshop are presented in these proceedings.

nucl-ex↗

First measurement of the Head-Tail directional nuclear recoil signature at energies relevant to WIMP dark matter searches

We present first evidence for the so-called Head-Tail asymmetry signature of neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the 1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils induced by Weakly Interacting Massive Particle (WIMPs) but one where the differential ionization is poorly understood. We show that the distribution of recoil energies and directions induced here by Cf-252 neutrons matches well that expected from massive WIMPs. The results open a powerful new means of searching for a galactic signature from WIMPs.

astro-ph↗

Measurement of the Range Component Directional Signature in a DRIFT-II Detector using 252Cf Neutrons

The DRIFT collaboration utilizes low pressure gaseous detectors to search for WIMP dark matter with directional signatures. A 252Cf neutron source was placed on each of the principal axes of a DRIFT detector in order to test its ability to measure directional signatures from the three components of very low energy (~keV/amu) recoil ranges. A high trigger threshold and the event selection procedure ensured that only sulfur recoils were analyzed. Sulfur recoils produced in the CS2 target gas by the 252Cf source closely match those expected from massive WIMP induced sulfur recoils. For each orientation of the source a directional signal from the range components was observed, indicating that the detector is directional along all 3 axes. An analysis of these results yields an optimal orientation for DRIFT detectors when searching for a directional signature from WIMPs. Additional energy dependent information is provided to aid in understanding this effect.

hep-ex↗

Measurements of neutrons produced by high-energy muons at the Boulby Underground Laboratory

We present the first measurements of the muon-induced neutron flux at the Boulby Underground Laboratory. The experiment was carried out with an 0.73 tonne liquid scintillator that also served as an anticoincidence system for the ZEPLIN-II direct dark matter search. The experimental method exploited the delayed coincidences between high-energy muon signals and gamma-rays from radiative neutron capture on hydrogen or other elements. The muon-induced neutron rate, defined as the average number of detected neutrons per detected muon, was measured as $0.079 \pm 0.003$ (stat.) neutrons/muon using neutron-capture signals above 0.55 MeV in a time window of 40-190 $μ$s after the muon trigger. Accurate Monte Carlo simulations of the neutron production, transport and detection in a precisely modeled laboratory and experimental setup using the GEANT4 toolkit gave a result 1.8 times higher than the measured value. The difference greatly exceeds all statistical and systematic uncertainties. As the vast majority of neutrons detected in the current setup were produced in lead we evaluated from our measurements the neutron yield in lead as $(1.31 \pm 0.06) \times 10^{-3}$ neutrons/muon/(g/cm$^2$) for a mean muon energy of about 260 GeV.

hep-ex↗

First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection

Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.

astro-ph↗

The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning

We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.

astro-ph↗

The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool

We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.

astro-ph↗

Simulations of neutron background in a time projection chamber relevant to dark matter searches

Presented here are results of simulations of neutron background performed for a time projection chamber acting as a particle dark matter detector in an underground laboratory. The investigated background includes neutrons from rock and detector components, generated via spontaneous fission and (alpha, n) reactions, as well as those due to cosmic-ray muons. Neutrons were propagated to the sensitive volume of the detector and the nuclear recoil spectra were calculated. Methods of neutron background suppression were also examined and limitations to the sensitivity of a gaseous dark matter detector are discussed. Results indicate that neutrons should not limit sensitivity to WIMP-nucleon interactions down to a level of (1 - 3) x 10^{-8} pb in a 10 kg detector.

hep-ex↗

Neutron background in large-scale xenon detectors for dark matter searches

Simulations of the neutron background for future large-scale particle dark matter detectors are presented. Neutrons were generated in rock and detector elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray muons. The simulation techniques and results are discussed in the context of the expected sensitivity of a generic liquid xenon dark matter detector. Methods of neutron background suppression are investigated. A sensitivity of $10^{-9}-10^{-10}$ pb to WIMP-nucleon interactions can be achieved by a tonne-scale detector.

hep-ex↗

Experimental Constraints on the Axion Dark Matter Halo Density

Most of the mass of the Milky Way galaxy is contributed by its halo, presumably in the form of non-interacting cold dark matter. The axion is a compelling cold dark matter candidate. We report results from a search which probes the local galactic halo axion density using the Sikivie RF cavity technique. Candidates over the frequency range 550$$ $\le$ f $\le$$$ 810 MHz (2.3$$ $μ$eV $\le$$$ m$_{a}$ $\le$ 3.4 $μ$eV) were investigated. The absence of a signal suggests that KSVZ axions contribute no more than 0.45 GeV/cm$^3$ of mass density to the local dark matter halo over this mass range.

astro-ph↗

Results from a High-Sensitivity Search for Cosmic Axions

We report the first results of a high-sensitivity (10^{-23} Watt) search for light halo axions through their conversion to microwave photons. At 90 percent confidence we exclude a KSVZ axion of mass 2.9 x 10^{-6} eV to 3.3 x 10^{-6} eV as the dark matter in the halo of our Galaxy.

astro-ph↗

First results from a second generation galactic axion experiment

We report first results from a large scale search for dark matter axions. The experiment probes axion masses of 1.3-13 micro-eV at a sensitivity which is about 50 times higher than previous pilot experiments. We have already scanned part of this mass range at a sensitivity better than required to see at least one generic axion model, the KSVZ axion. Data taking at full sensitivity commenced in February 1996 and scanning the proposed mass range will require three years.

astro-ph↗

A 2nd generation cosmic axion experiment

An experiment is described to detect dark matter axions trapped in the halo of our galaxy. Galactic axions are converted into microwave photons via the Primakoff effect in a static background field provided by a superconducting magnet. The photons are collected in a high Q microwave cavity and detected by a low noise receiver. The axion mass range accessible by this experiment is 1.3-13 micro-eV. The expected sensitivity will be roughly 50 times greater than achieved by previous experiments in this mass range. The assembly of the detector is well under way at LLNL and data taking will start in mid-1995.

astro-ph↗