Searcharxiv⌕ Search

arXiv subjects

E. Ellingwood

Publications and source records attributed to E. Ellingwood.

25 records · Page 2Linked to original sources

Directionality of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R < 1.072 with 90% confidence level

physics.ins-det↗

Electron-beam Calibration of Aerogel Tiles for the HELIX RICH Detector

The HELIX cosmic-ray detector is a balloon-borne instrument designed to measure the flux of light isotopes in the energy range from 0.2 GeV/n to beyond 3 GeV/n. It will rely on a ring-imaging Cherenkov (RICH) detector for particle identification at energies greater than 1 GeV/n and will use aerogel tiles with refractive index near 1.15 as the radiator. To achieve the performance goals of the experiment it is necessary to know the refractive index and its position dependence over the lateral extent of the tiles to a precision of O(10$^{-4}). In this paper we describe the apparatus and methods developed to calibrate the HELIX tiles in an electron beam, in order to meet this requirement.

astro-ph.IM↗

First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector

Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.

astro-ph.CO↗

Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors

We describe a technique, applicable to liquid-argon-based dark matter detectors, allowing for discrimination of alpha-decays in detector regions with incomplete light collection from nuclear-recoil-like events. Nuclear recoils and alpha events preferentially excite the liquid argon (LAr) singlet state, which has a decay time of ~6 ns. The wavelength-shifter TPB, which is typically applied to the inside of the active detector volume to make the LAr scintillation photons visible, has a short re-emission time that preserves the LAr scintillation timing. We developed a wavelength-shifting polymeric film - pyrene-doped polystyrene - for the DEAP-3600 detector and describe the production method and characterization. At liquid argon temperature, the film's re-emission timing is dominated by a modified exponential decay with time constant of 279(14) ns and has a wavelength-shifting efficiency of 46.4(2.9) % relative to TPB, measured at room temperature. By coating the detector neck (a region outside the active volume where the scintillation light collection efficiency is low) with this film, the visible energy and the scintillation pulse shape of alpha events in the neck region are modified, and we predict that through pulse shape discrimination, the coating will afford a suppression factor of O($10^{5}$) against these events.

physics.ins-det↗

Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K

Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experiments where the main signal is visible scintillation light, or UV scintillation light that is absorbed and re-emitted at visible wavelengths by a wavelength shifter. Some of these experiments operate at low temperature. The fluorescence of these materials could change with temperature so we have studied the fluorescence of the acrylic used in the DEAP-3600 experiment down to a temperature of 4 K, and compared it to the common wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). The light yield and wavelength spectra of these materials were characterized by exciting the sample with 285 nm UV light which acted as a proxy for Cherenkov light in the detector. Spectral measurements indicate at least part of the fluorescence of the acrylic is due to additives. Time-resolved measurements show the light yields of our acrylic sample, TPB sample, and the relative light between both samples, all increase when cooling down. At room temperature, the light yield of our acrylic sample relative to the TPB sample is 0.3 %, while it reaches 0.5 % at 4 K. The main fluorescence time constant of the acrylic is less than a few nanoseconds.

physics.ins-det↗

Fluorescence of pyrene-doped polystyrene films from room temperature down to 4 K for wavelength-shifting applications

In liquid argon-based particle detectors, slow wavelength shifters (WLSs) could be used alongside the common, nanosecond scale, WLS tetraphenyl butadiene (TPB) for background mitigation purposes. At room temperature, pyrene has a moderate fluorescence light yield (LY) and a time constant of the order of hundreds of nanoseconds. In this work, four pyrene-doped polystyrene films with various purities and concentrations were characterized in terms of LY and decay time constants in a range of temperature between 4 K and 300 K under ultraviolet excitation. These films were found to have a LY between 35 and 50% of that of evaporated TPB. All light yields increase when cooling down, while the decays slow down. At room temperature, we observed that pyrene purity is strongly correlated with emission lifetime: highest obtainable purity samples were dominated by decays with emission time constants of $\sim$ 250-280 ns, and lower purity samples were dominated by an $\sim$ 80 ns component. One sample was investigated further to better understand the monomer and excimer emissions of pyrene. The excimer-over-monomer intensity ratio decreases when the temperature goes down, with the monomer emission dominating below $\sim$ 87 K.

physics.ins-det↗

Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.

physics.ins-det↗