SearcharxivSearch

arXiv subjects

E. Gau

Publications and source records attributed to E. Gau.

3 recordsLinked to original sources

IXPE Observations of the Blazar Mrk 501 in 2022: A Multiwavelength View

The blazar Markarian 501 (Mrk 501) was observed on three occasions over a 4-month period between 2022 March and 2022 July with the Imaging X-ray Polarimetry Explorer (IXPE). In this paper, we report for the first time on the third IXPE observation, performed between 2022 July 9 and 12, during which IXPE detected a linear polarization degree of $\Pi_X=6\pm2$ per cent at a polarization angle, measured east of north, of $\Psi_X=143^\circ\pm11^\circ$ within the 2-8 keV X-ray band. The X-ray polarization angle and degree during this observation are consistent with those obtained during the first two observations. The chromaticity of the polarization across radio, optical, and X-ray bands is likewise consistent with the result from the simultaneous campaigns during the first two observations. Furthermore, we present two types of models to explain the observed spectral energy distributions (SEDs) and energy-resolved polarization: a synchrotron self-Compton model with an anisotropic magnetic field probability distribution in the emitting volume, as well as an energy-stratified shock model. Our results support both the shock scenario as well as support that small levels of magnetic field anisotropy can explain the observed polarization.

astro-ph.HE

Systematic effects on a Compton polarimeter at the focus of an X-ray mirror

XL-Calibur is a balloon-borne Compton polarimeter for X-rays in the $\sim$15-80 keV range. Using an X-ray mirror with a 12 m focal length for collecting photons onto a beryllium scattering rod surrounded by CZT detectors, a minimum-detectable polarization as low as $\sim$3% is expected during a 24-hour on-target observation of a 1 Crab source at 45$^{\circ}$ elevation. Systematic effects alter the reconstructed polarization as the mirror focal spot moves across the beryllium scatterer, due to pointing offsets, mechanical misalignment or deformation of the carbon-fiber truss supporting the mirror and the polarimeter. Unaddressed, this can give rise to a spurious polarization signal for an unpolarized flux, or a change in reconstructed polarization fraction and angle for a polarized flux. Using bench-marked Monte-Carlo simulations and an accurate mirror point-spread function characterized at synchrotron beam-lines, systematic effects are quantified, and mitigation strategies discussed. By recalculating the scattering site for a shifted beam, systematic errors can be reduced from several tens of percent to the few-percent level for any shift within the scattering element. The treatment of these systematic effects will be important for any polarimetric instrument where a focused X-ray beam is impinging on a scattering element surrounded by counting detectors.

astro-ph.IM

The design and performance of the XL-Calibur anticoincidence shield

The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincidence shield, as well as the performance measured during the week-long maiden flight from Esrange Space Centre to the Canadian Northwest Territories in July 2022. The in-flight performance of the shield followed design expectations, with a veto threshold <100 keV and a measured background rate of ~0.5 Hz (20-40 keV). This is compatible with the scientific goals of the mission, where %-level minimum detectable polarisation is sought for a Hz-level source rate.

astro-ph.IM