SearcharxivSearch

arXiv subjects

E. Jericha

Publications and source records attributed to E. Jericha.

At least 19 recordsLinked to original sources

Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment

The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CE$\nu$NS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this work, the cryogenic target-detector module for the NUCLEUS Technical Run was developed and commissioned at the Technical University of Munich. The module comprises four gram-scale CaWO$_4$ detectors, each equipped with two Transition Edge Sensors (TES), providing a total target mass of 6.96 g. We present the design, integration, detector characterization, and X-ray-based energy calibration of these detectors. Across six characterized detectors, a mean baseline resolution of $\overline{\sigma}_{\mathrm{BL}} = (2.79 \pm 0.60)\,\mathrm{eV}$ was achieved. The best-performing detector reached $\sigma_{\mathrm{BL}} = (2.16 \pm 0.02_{\mathrm{stat}})\,\mathrm{eV}$, surpassing the design goal by a factor of two and representing a state-of-the-art result for a cryogenic CaWO$_4$ detector. The target detector module was successfully operated simultaneously with the surrounding Cryogenic Outer Veto, which consists of six kg-scale Ge detectors for background discrimination, showing no measurable cross-talk. These results demonstrate the readiness of the target-detector system for the NUCLEUS Technical Run at Chooz and mark a key milestone in the development of cryogenic detectors for reactor-CE$\nu$NS measurements.

physics.ins-det

Improved $^{94}$Mo neutron resonance parameters from neutron capture and transmission measurements at n_TOF and GELINA

We report high-resolution measurements of the $^{94}\mathrm{Mo}(\mathrm{n},\gamma)^{95}\mathrm{Mo}$ cross section in the neutron energy range from a few eV up to about 250 keV, performed at the n_TOF facility (CERN), and of the $^{94}\mathrm{Mo}(\mathrm{n},\mathrm{tot})$ cross section up to 32 keV, measured at GELINA (JRC Geel). A combined R-matrix analysis of capture and transmission data yields significantly improved neutron-resonance parameters for $^{94}$Mo. A total of 186 resonances were observed in this analysis of which 127 reported here for the first time. The resulting Maxwellian-averaged cross section at stellar temperatures relevant to the slow neutron-capture process (s-process) is approximately 25% lower than previous evaluations and literature values. To assess the astrophysical impact of the revised cross section, we performed s-process nucleosynthesis calculations for low-mass asymptotic giant branch stars. Despite the substantial reduction in the $^{94}\mathrm{Mo}(\mathrm{n},\gamma)^{95}\mathrm{Mo}$ rate, the final yields vary by only 3-4%. This demonstrates that the isotopic budget of $^{94}$Mo in AGB stars is primarily governed by the branching flow at $^{94}\mathrm{Nb}$ rather than by the neutron-capture destruction on $^{94}$Mo itself. The new cross section thus helps disentangle nuclear cross-section uncertainties from branching-flow effects in the s-process production of $^{94}$Mo.

nucl-ex

Reactor operation induced thermal effects on neutron flux measurements using $^3$He neutron detectors at a TRIGA Mk II research reactor

A variation of the measured neutron flux using $^3$He detectors at a TRIGA Mk II nuclear research reactor during steady-state operation is reported in this article. The observed effect shows a statistically significant anti-correlation between the temperature in the reactor pool and recorded neutron counts. Following reactor start-up under nominal operating conditions, the effect occurs for a specific time period until thermal equilibrium and a constant neutron count rate are reached. Simultaneous neutron and temperature measurements are performed in different configurations around the reactor in order to gain qualitative insights about the temperature dependent count rate behavior. Possible origins of the effect are identified and further measurements for a more detailed investigation are suggested.

physics.ins-det

Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving the best sensitivity for this kind of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information on different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. With both techniques at the same time, we obtained a baseline resolution of 2.94 $\pm$ 0.05 (stat) eV using a CaWO4 based detector, achieving a promising result in view of the first run of NUCLEUS at the experimental site.

physics.ins-det

Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches

The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters operated at the Chooz nuclear power plant in France. Access to recoil energies at the $\mathcal{O}(10~\mathrm{eV})$ scale enables CE$\nu$NS studies at extremely low momentum transfer and provides enhanced sensitivity to new physics. In this work, we present sensitivity projections for the upcoming NUCLEUS technical and physics runs, incorporating a data-driven treatment of the low-energy excess (LEE) observed during commissioning. We develop a likelihood framework that exploits reactor-power variation to disentangle signal and background in a low signal-to-background regime and to assess the impact of the dominant systematic uncertainties. For the Technical Run with a 7 g CaWO$_4$ target, we find competitive sensitivity to several scenarios beyond the Standard Model, which do not require a CE$\nu$NS observation. For the Physics Run, assuming complete suppression of the LEE, we project a 4.7 $\sigma$ observation of CE$\nu$NS with a statistical precision of about 20 % in 1 year, enabling a determination of the weak mixing angle at the lowest momentum transfer probed to date with CE$\nu$NS and leading CE$\nu$NS-based constraints on the neutrino charge radius and new mediator models.

hep-ex

First $^{94}$Nb($n,\gamma$) Measurement: Constraining the Nucleosynthetic Origin of $^{94}$Mo in Presolar Grains

Isotopic measurements of presolar silicon carbide grains from dying stars have revealed a puzzling overabundance of $^{94}$Mo that stellar nucleosynthesis models have failed to reproduce for two decades. This discrepancy challenged our understanding of the slow neutron-capture process ($s$-process) that forges approximately half of the elements heavier than iron. The key uncertainty lies at $^{94}$Nb, a radiactive branching point where competition between neutron capture and beta decay governs the $^{94}$Mo production, yet the neutron-capture cross section had never been measured. Here we report the first experimental determination of the $^{94}$Nb(n,$\gamma$)$^{95}$Nb cross section important for Mo isotopic abundances. The measurement was enabled by a coordinated effort involving high-purity target preparation at Institute of Solid State and Materials Research (IFW) Dresden, radioactive sample production at the Institut Laue-Langevin (ILL) Grenoble, radiochemical characterization at Paul Scherrer Institute (PSI) Villigen, and the Time-of-Flight CERN n$\_$TOF facility using for the first time segmented total-energy detectors. Incorporation of the resulting Maxwellian-averaged cross section into fully coupled nucleosynthesis models of low-mass asymptotic giant branch (AGB) stars brings them into agreement with the presolar grain data. These results remove a major nuclear-physics input uncertainty at the $^{94}$Nb branching point and provide a firmer foundation for understanding the origin of $^{94}$Mo in the solar system.

nucl-ex

Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $(-0.59 \pm 0.06)$, when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.

physics.ins-det

Observation of two nuclear recoil peaks induced by neutron capture on Al2O3

We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic Al$_2$O$_3$ detector developed by the NUCLEUS collaboration for the detection of reactor neutrinos via coherent elastic neutrino-nucleus (CEvNS) process. Data collected at the Technical University of Munich in 2024 with a $^{252}$Cf source reveal a main recoil line at 1145 eV from single-$\gamma$ de-excitation of $^{28}$Al and a newly observed structure near 575 eV originating from several two-$\gamma$ cascades. The latter constitutes the first direct measurement of a nuclear recoil line induced by multi-$\gamma$ cascades. It is predicted by our simulations when the recoiling nucleus has time to stop before the emission of the next $\gamma$-ray in the cascade. These results demonstrate the potential performance of the CRAB (Calibration Recoil for Accurate Bolometry) method for in situ nuclear recoil calibration and highlight the importance of accurately modeling recoil stopping and nuclear de-excitation times in cryogenic detectors of CEvNS and dark matter interactions.

physics.ins-det

Particle background characterization and prediction for the NUCLEUS reactor CE$\nu$NS experiment

NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CE$\nu$NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE$\nu$NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE$\nu$NS signal region of interest between 10 and 100 eV, a total particle background rate of $\sim$ 250 d$^{-1}$kg$^{-1}$keV$^{-1}$ is expected in the CaWO$_4$ target detectors. This corresponds to a signal-to-background ratio $\gtrsim$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE$\nu$NS.

physics.ins-det

Commissioning of the NUCLEUS Experiment at the Technical University of Munich

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO$_4$ targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW$_{\text{th}}$ reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.

hep-ex

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det

The CRAB facility at the TU Wien TRIGA reactor: status and related physics program

The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. A crown of BaF$_2$ detectors installed outside the dewar enables coincident detection of the high-energy $\gamma$ escaping the target crystal after neutron capture. After the presentation of all components of the setup we report the analysis of first commissioning data with a CaWO$_4$ detector of the \NUCLEUS experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $^{187}$W. Finally, we present the first evidence of neutron-capture induced coincidences between $\gamma$-detectors and a cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO$_4$, Al$_2$O$_3$, Ge and Si.

physics.ins-det

Neutron capture measurements for s-process nucleosynthesis; A review about CERN n_TOF developments and contributions

This article presents a review about the main CERN n\_TOF contributions to the field of neutron-capture experiments of interest for $s$-process nucleosynthesis studies over the last 25 years, with special focus on the measurement of radioactive isotopes. A few recent capture experiments on stable isotopes of astrophysical interest are also discussed. Results on $s$-process branching nuclei are appropriate to illustrate how advances in detection systems and upgrades in the facility have enabled increasingly challenging experiments and, as a consequence, have led to a better understanding and modeling of the $s$-process mechanism of nucleosynthesis. New endeavors combining radioactive-ion beams from ISOLDE for the production of radioisotopically pure samples for activation experiments at the new NEAR facility at n\_TOF are briefly discussed. On the basis of these new exciting results, also current limitations of state-of-the-art TOF and activation techniques will be depicted, thereby showing the pressing need for further upgrades and enhancements on both facilities and detection systems. A brief account of the potential technique based on inverse kinematics for direct neutron-capture measurements is also presented.

nucl-ex

Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures

With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low $(6.22 \pm 0.07)$ eV baseline resolution on a gram-scale CaWO$_4$ cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.

physics.ins-det

Radiative neutron capture cross section of $^{242}$Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV

Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For $^{242}$Pu, the Nuclear Energy Agency (NEA) recommends 8--12% accuracy in the fast energy region (2--500 keV), compared to the current uncertainty of 35%. Moreover, integral experiments and previous measurements suggest the evaluated $^{242}$Pu(n,$\gamma$) cross section is overestimated, particularly in the JEFF-3.3 library, which shows a 14% overestimation between 1 keV and 1 MeV. Recent measurements from LANSCE reported a 20--30% reduction in the 1--40 keV range relative to evaluations. To solve these discrepancies, the $^{242}$Pu(n,$\gamma$) cross section was measured from 1 to 600 keV at CERN n_TOF-EAR1 facility using a 95(4) mg $^{242}$Pu target, enriched to 99.959%. Gamma rays from neutron capture were detected with an array of C$_6$D$_6$ scintillators and a novel application of the Pulse Height Weighting Technique was employed. The resulting cross section presents a systematic uncertainty between 8 and 12%, reducing the current uncertainties of 35\% and achieving the accuracy requested by the NEA. Analysis using FITACS produced average resonance parameters, consistent with the analysis of the resolved resonance region. Our data align well with Wisshak and Kaeppeler, and are 10--14\% lower than JEFF-3.3 in the 1--250 keV range, helping to achieve consistency with integral benchmarks. At higher energies, our results are in reasonable agreement with ENDF/B-VIII.1 and JEFF-3.3. In contrast, DANCE results appear to underestimate the cross section by a factor of 2--3 above a few keV.

nucl-ex

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called $\gamma$-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps toward such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n\_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C$_{6}$D$_{6}$ detectors, and one LaCl$_{3}$(Ce) detector. The performance of these detection systems is compared using $^{93}$Nb($n$,$\gamma$) data. We also developed a detailed \textsc{Geant4} Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a $\gamma$ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigaged experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

physics.ins-det

Measurement and analysis of the $^{246}$Cm and $^{248}$Cm neutron capture cross-sections at the EAR2 of the n TOF facility

The $^{246}$Cm(n,$\gamma$) and $^{248}$Cm(n,$\gamma$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water reactors and innovative reactor systems. In particular, the neutron capture in $^{246}$Cm and $^{248}$Cm open the path for the formation of other Cm isotopes and heavier elements such as Bk and Cf and the knowledge of (n,$\gamma$) cross-sections of these Cm isotopes plays an important role in the transport, transmutation and storage of the spent nuclear fuel. The reactions $^{246}$Cm(n,$\gamma$) and $^{248}$Cm(n,$\gamma$) have been the two first capture measurements analyzed at n_TOF EAR2. Until this experiment and two recent measurements performed at J-PARC, there was only one set of data of the capture cross-sections of $^{246}$Cm and $^{248}$Cm, that was obtained in 1969 in an underground nuclear explosion experiment. In the measurement at n_TOF a total of 13 resonances of $^{246}$Cm between 4 and 400 eV and 5 of $^{248}$Cm between 7 and 100 eV have been identified and fitted. The radiative kernels obtained for $^{246}$Cm are compatible with JENDL-5, but some of them are not with JENDL-4, which has been adopted by JEFF-3.3 and ENDF/B-VIII.0. The radiative kernels obtained for the first three $^{248}$Cm resonances are compatible with JENDL-5, however, the other two are not compatible with any other evaluation and are 20% and 60% larger than JENDL-5.

nucl-ex

Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments

One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.

physics.ins-det